CoChat

Normative cardiopulmonary exercise data for endurance athletes: the C ardiopulmonary H ealth and E ndurance E xercise R egistry (CHEER)

Petek, Bradley J, Tso, Jason V, Churchill, Timothy W, Guseh, J Sawalla, Loomer, Garrett, DiCarli, Milena, Lewis, Gregory D, Weiner, Rory B, Kim, Jonathan H, Wasfy, Meagan M, Baggish, Aaron L · 2022 · European Journal of Preventive Cardiology
Cited by 41

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

Aims: Accurate interpretation of cardiopulmonary exercise testing (CPET) relies on age, gender, and exercise modality-specific reference values. To date, clinically applicable CPET reference values derived from a source population of endurance athletes (EAs) have been lacking. The purpose of this study was to generate CPET reference values for use in the clinical assessment of EA. Methods and Results: Prospective data accrued during the clinical care of healthy EA were used to derive CPET reference values and to develop novel equations for V˙O2peak. The performance of these equations was compared to the contemporary standard of care equations and assessed in a discrete EA validation cohort. A total of 272 EA (age = 42 ± 15 years, female = 31%, V˙O2peak = 3.6 ± 0.83 L/min) met inclusion criteria and comprised the derivation cohort. V˙O2peak prediction equations derived from general population cohorts described a modest amount of V˙O2peak variability [R2 = 0.58–0.70, root mean square error (RMSE) = 0.46–0.54 L/min] but were mis-calibrated (calibration-in-the-large = 0.45–1.18 L/min) among EA leading to significant V˙O2peak underestimation. Newly derived, externally validated V˙O2peak prediction equations for EA that included age, sex, and height for both treadmill (R2 = 0.74, RMSE = 0.42 L/min) and cycle ergometer CPET (Cycle: R2 = 0.69, RMSE = 0.42 L/min) demonstrated improved accuracy. Conclusion: Commonly used V˙O2peak prediction equations derived from general population cohorts perform poorly among competitive EA. Newly derived CPET reference values including novel V˙O2peak prediction equations may improve the clinical utility of CPET in this rapidly growing patient population.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/eurjpc/zwab150

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 41

Metadata

Authors
Petek, B. J., Tso, J. V., Churchill, T. W., Guseh, J. S., Loomer, G., DiCarli, M., Lewis, G. D., Weiner, R. B., Kim, J. H., Wasfy, M. M., & Baggish, A. L.
Venue
European Journal of Preventive Cardiology
Published
2021-09-06
Volume
29
Issue
3
Pages
536-544
ISSN
  • 2047-4873 (ISSN-L)
  • 2047-4881
OpenAlex
W3198241557
Cited by
41
References
7
FWCI
6.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Normative cardiopulmonary exercise data for endurance athletes: the C ardiopulmonary H ealth and E ndurance E xercise R egistry (CHEER). https://app.cochat.ai/papers/10.1093/eurjpc/zwab150
The paper
Petek, B. J., Tso, J. V., Churchill, T. W., Guseh, J. S., Loomer, G., DiCarli, M., Lewis, G. D., Weiner, R. B., Kim, J. H., Wasfy, M. M., & Baggish, A. L. (2022). Normative cardiopulmonary exercise data for endurance athletes: the C ardiopulmonary H ealth and E ndurance E xercise R egistry (CHEER). European Journal of Preventive Cardiology. https://doi.org/10.1093/eurjpc/zwab150

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.