Long-term follow-up after radiofrequency catheter ablation for atrial fibrillation
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
AIMS: Data on long-term follow-up of patients who have undergone catheter ablation for atrial fibrillation (AF) are very limited. This report aimed at presenting clinical outcome and AF-free survival after pulmonary vein (PV) isolation over an extended (>3 years) follow-up period. METHODS AND RESULTS: Thirty-nine patients subjected to PV isolation for paroxysmal AF were followed-up for at least 3 years according to a strict protocol. Fourteen patients (35.8%) had one, 19 patients (50%) had two, and 6 patients (15.4%) had three ablation procedures. At end of follow-up (42.2 +/- 6.0 months), 17 patients (43.5%) were completely free of AF or other atrial arrhythmia, and 26 patients (66.6%) had symptomatic improvement. The long-term success rate was 21.4% for patients subjected to a single ablation procedure, 52.6% for patients subjected to two catheter ablation procedures, and 66.7% for patients who underwent three ablation procedures (P = 0.094). There was also a trend for patients who underwent a combination of different ablation procedures (ostial, antral, and/or circumferential) to have a higher AF-free survival when compared with patients subjected to the same procedure (P-value for log-rank test = 0.036). CONCLUSION: Catheter ablation does not eliminate paroxysmal AF in up to 56% of patients in the long term, despite the use of two or three ablation procedures in two-thirds of them. However, it confers symptomatic improvement in 67% of treated patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852
Pappone, C., Rosanio, S., Augello, G., Gallus, G., Vicedomini, G., Mazzone, P., Gulletta, S., Gugliotta, F., Pappone, A., Santinelli, V., et al. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00577-1 · Cited by 781
Cited by
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-012-9672-7 · Cited by 1,675
Self-citationCalkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Self-citationGanesan, A. N., Shipp, N. J., Brooks, A. G., Kuklik, P., Lau, D. H., Lim, H. S., Sullivan, T., Roberts‐Thomson, K. C., & Sanders, P. (2013) · Journal of the American Heart Association · doi:10.1161/jaha.112.004549 · Cited by 800
“Segmental PV isolation was used in 4 studies.(11,13,14,23) The stepwise ablation technique was the procedure of choice in 2 studies.”
MethodVenice Chart International Consensus Document on Atrial Fibrillation Ablation
NATALE, A., RAVIELE, A., ARENTZ, T., CALKINS, H., CHEN, S., HAÏSSAGUERRE, M., HINDRICKS, G., HO, Y., KUCK, K. H., MARCHLINSKI, F., et al. (2007) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2007.00816.x · Cited by 406
Long-Term Outcome After Successful Catheter Ablation of Atrial Fibrillation
Tzou, W. S., Marchlinski, F. E., Zado, E. S., Lin, D., Dixit, S., Callans, D. J., Cooper, J. M., Bala, R., Garcia, F., Hutchinson, M. D., et al. (2010) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.923771 · Cited by 237
Selective ganglionated plexi ablation for paroxysmal atrial fibrillation
Pokushalov, E., Romanov, A., Shugayev, P., Artyomenko, S., Shirokova, N., Turov, A., & Katritsis, D. G. (2009) · Heart Rhythm · doi:10.1016/j.hrthm.2009.05.018 · Cited by 234
Self-citationBoersma, L. V. A., Wijffels, M. C. E. F., Oral, H., Wever, E. F. D., & Morady, F. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.08.037 · Cited by 197
Pokushalov, E., Romanov, A., Katritsis, D. G., Artyomenko, S., Shirokova, N., Karaskov, A., Mittal, S., & Steinberg, J. S. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2013.04.016 · Cited by 185
Self-citationAbecasis, J., Dourado, R., Ferreira, A., Saraiva, C., Cavaco, D., Santos, K. R., Morgado, F. B., Adragao, P., & Silva, A. (2009) · Europace · doi:10.1093/europace/eup198 · Cited by 169
“Left atrium enlargement is related to the presence of AF in both pts with structural heart disease and those with lone AF, suggesting that there is an anatomical substrate promoting the development of the arrhythmia.(9) This enlargement, termed atrial remodelling, may be reversed with the restoration of normal sinus r…”
BackgroundAnselmino, M., Matta, M., D'ascenzo, F., Pappone, C., Santinelli, V., Bunch, T. J., Neumann, T., Schilling, R. J., Hunter, R. J., Noelker, G., et al. (2015) · Europace · doi:10.1093/europace/euv214 · Cited by 88
“As illustrated in Figure 3, the number of patients receiving AADs significantly decreased during follow-up from 55 (46-74)% to 29 (17-41)% (p<0.”
BackgroundSelf-citation
Metadata
- Authors
- Katritsis, D., Wood, M. A., Giazitzoglou, E., Shepard, R. K., Kourlaba, G., & Ellenbogen, K. A.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-02-19
- Volume
- 10
- Issue
- 4
- Pages
- 419-424
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2119332942
- Cited by
- 64
- References
- 2
- FWCI
- 6.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.