Long-term patient acceptance of and satisfaction with implanted device remote monitoring
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
AIMS: To evaluate patients' acceptance and satisfaction of the Home Monitoring (HM) remote control system after 1 year of follow-up by a self-made questionnaire (HM Acceptance and Satisfaction Questionnaire, HoMASQ) specifically designed for this purpose. METHODS AND RESULTS: The HoMASQ contains 12 items designed to investigate five different aspects strictly connected to patient's acceptance and satisfaction of remote monitoring: (i) relationship with their healthcare provider, (ii) easy of use of HM technology, (iii) related psychological aspects, (iv) implications on general health, and (v) overall satisfaction. Each item was rated on a five-point scale: from 0 to 4 with favourable responses score > or =2. The theoretical maximum total score (the highest detected acceptance and satisfaction level) was 48. The HoMASQ was given to 119 patients followed by HM during the 1-year follow-up visit. Ninety-nine percent of all the administered questionnaire items were answered. The mean total score was 40.8 +/- 5.4 with a mean percentage of favourable answers of 96.3 +/- 18.8% (CI 95.2 - 97.2%). The mean scores for each of the five areas of the HoMASQ were: 3.0 +/- 0.9 for relationship, 3.4 +/- 0.6 for easy of use, 3.4 +/- 0.9 for psychological aspects, and 3.4 +/- 0.8 for clinical implication and overall satisfaction. Cronbach's alpha for reliability of the HoMASQ was 0.73. CONCLUSION: A high level of acceptance and satisfaction after 1-year remote control by HM was detected by the five-point scale HoMASQ, which showed a good internal reliability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Systematic review of studies of patient satisfaction with telemedicine
Mair, F. (2000) · BMJ · doi:10.1136/bmj.320.7248.1517 · Cited by 734
Wilkoff, B. L., Auricchio, A., Brugada, J., Cowie, M., Ellenbogen, K. A., Gillis, A. M., Hayes, D. L., Howlett, J. G., Kautzner, J., Love, C. J., et al. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.04.013 · Cited by 364 · cited 1×
“Since 2000, when the first remote control system of implantable devices was introduced in clinical practice, the diffusion of this new technology has rapidly increased and it is now becoming the gold-standard for the follow-up of patients with pacemaker and implantable cardioverter defibrillator (ICD).(1) During the l…”
BackgroundWilkoff, B. L., Auricchio, A., Brugada, J., Cowie, M., Ellenbogen, K. A., Gillis, A. M., Hayes, D. L., Howlett, J. G., Kautzner, J., Love, C. J., et al. (2008) · Europace · doi:10.1093/europace/eun122 · Cited by 231
Remote Monitoring of Implantable Cardioverter Defibrillators: A Prospective Analysis
SCHOENFELD, M. H., COMPTON, S. J., MEAD, R. H., WEISS, D. N., SHERFESEE, L., ENGLUND, J., & MONGEON, L. R. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00524.x · Cited by 194
MARZEGALLI, M., LUNATI, M., LANDOLINA, M., PEREGO, G. B., RICCI, R. P., GUENZATI, G., SCHIRRU, M., BELVITO, C., BRAMBILLA, R., MASELLA, C., et al. (2008) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2008.01175.x · Cited by 134 · cited 1×
“Although safety, efficacy, and impact on standard care of remote control have been already demonstrated, 7 few data on long-term patient acceptance and satisfaction are available.(4,8) –10”
BackgroundSelf-citation
Cited by
Slotwiner, D., Varma, N., Akar, J. G., Annas, G., Beardsall, M., Fogel, R. I., Galizio, N. O., Glotzer, T. V., Leahy, R. A., Love, C. J., et al. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.05.008 · Cited by 532
Self-citationTelemedicine and cardiac implants: what is the benefit?
Varma, N., & Ricci, R. P. (2013) · European Heart Journal · doi:10.1093/eurheartj/ehs388 · Cited by 102
“Patient acceptance and satisfaction have been demonstrated for different aspects including relationship with their health-care provider, ease of use of technology, psychological aspects, implications on general health, and overall satisfaction.(60) In spite of initial concerns, ease of use and acceptance of RM was hig…”
BackgroundSelf-citationDubner, S., Auricchio, A., Steinberg, J. S., Vardas, P., Stone, P., Brugada, J., Piotrowicz, R., Hayes, D. L., Kirchhof, P., Breithardt, G., et al. (2012) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2011.00484.x · Cited by 47
Pedersen, S. S., Knudsen, C., Dilling, K., Sandgaard, N. C. F., & Johansen, J. B. (2016) · Europace · doi:10.1093/europace/euw109 · Cited by 43
Versteeg, H., Pedersen, S. S., Mastenbroek, M. H., Redekop, W. K., Schwab, J. O., Mabo, P., & Meine, M. (2014) · Netherlands Heart Journal · doi:10.1007/s12471-014-0587-z · Cited by 32
“Prospective cohort studies using short ad hoc questionnaires have reported that 60–95 % of ICD patients are highly satisfied with remote monitoring and that it makes them feel safe [17–22].”
Background
Metadata
- Authors
- Ricci, R. P., Morichelli, L., Quarta, L., Sassi, A., Porfili, A., Laudadio, M. T., Gargaro, A., & Santini, M.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-03-02
- Volume
- 12
- Issue
- 5
- Pages
- 674-679
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2087279293
- Cited by
- 138
- References
- 5
- FWCI
- 11.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Long-term patient acceptance of and satisfaction with implanted device remote monitoring. https://app.cochat.ai/papers/10.1093/europace/euq046
- The paper
- Ricci, R. P., Morichelli, L., Quarta, L., Sassi, A., Porfili, A., Laudadio, M. T., Gargaro, A., & Santini, M. (2010). Long-term patient acceptance of and satisfaction with implanted device remote monitoring. Europace. https://doi.org/10.1093/europace/euq046
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.