Detection of atrial high-rate events by continuous Home Monitoring: clinical significance in the heart failure-cardiac resynchronization therapy population
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
AIMS: Uncertainty exists over the importance of device-detected short-duration atrial arrhythmias. Continuous atrial diagnostics, through home monitoring (HM) technology (BIOTRONIK, Berlin, Germany), provides a unique opportunity to assess frequency and quantity of atrial fibrillation (AF) episodes defined as atrial high-rate events (AHRE). METHODS AND RESULTS: Prospective data from 560 heart failure (HF) patients (age 67 ± 10 years, median ejection fraction 27%) patients with a cardiac resynchronization therapy (CRT) device capable of HM from two multi-centre studies were analysed. Atrial high-rate events burden was defined as the duration of mode switch in a 24-h period with atrial rates of >180 beats for at least 1% or total of 14 min per day. The primary endpoint was incidence of a thromboembolic (TE) event. Secondary endpoints were cardiovascular death, hospitalization because of AF, or worsening HF. Over a median 370-day follow-up AHRE occurred in 40% of patients with 11 (2%) patients developing TE complications and mortality rate of 4.3% (24 deaths, 16 with cardiovascular aetiology). Compared with patients without detected AHRE, patients with detected AHRE>3.8 h over a day were nine times more likely to develop TE complications (P= 0.006). The majority of patients (73%) did not show a temporal association with the detected atrial episode and their adverse event, with a mean interval of 46.7 ± 71.9 days (range 0-194) before the TE complication. CONCLUSION: In a high-risk cohort of HF patients, device-detected atrial arrhythmias are associated with an increased incidence of TE events. A cut-off point of 3.8 h over 24 h was associated with significant increase in the event rate. Routine assessment of AHRE should be considered with other data when assessing stroke risk and considering anti-coagulation initiation and should also prompt the optimization of cardioprotective HF therapy in CRT patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Developed with the special contribution of the European Heart Rhythm Association (EHRA), Endorsed by the European Association for Cardio-Thoracic Surgery (EACTS), Authors/Task Force Members, Camm, A. J., Kirchhof, P., Lip, G. Y. H., Schotten, U., Savelieva, I., Ernst, S., Van Gelder, I. C., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq278 · Cited by 5,864
Gage, B. F., Waterman, A. D., Shannon, W., Boechler, M., Rich, M. W., & Radford, M. J. (2001) · JAMA · doi:10.1001/jama.285.22.2864 · Cited by 4,832
Impact of Atrial Fibrillation on the Risk of Death: The Framingham Heart Study
Benjamin, E. J., Wolf, P. A., D’Agostino, R. B., Silbershatz, H., Kannel, W. B., & Levy, D. (1998) · Circulation · doi:10.1161/01.cir.98.10.946 · Cited by 4,575 · cited 1×
“Others have suggested that patients with device-detected atrial arrhythmias have more ‘severe underlying heart disease’ and hence higher mortality;(13) while it is also well known that the development of AF is a marker of increased mortality in patients with underlying heart disease.(20)”
BackgroundA comparison of rate control and rhythm control in patients with atrial fibrillation
(2002) · New England Journal of Medicine · doi:10.1056/nejmoa021328 · Cited by 4,405 · cited 1×
“A significant proportion of AF is asymptomatic but carries important prognostic implications, as emphasized in the AFFIRM study.(2) Patients with undetected, ‘unprotected’ paroxysms of AF remain at a continued risk of TE.”
BackgroundGlotzer, T. V., Daoud, E. G., Wyse, D. G., Singer, D. E., Ezekowitz, M. D., Hilker, C., Miller, C., Qi, D., & Ziegler, P. D. (2009) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.109.849638 · Cited by 879 · cited 3×
“Subsequently, Glotzer et al.(9) attempted to define a threshold for stroke risk in device-detected AF.”
BackgroundGlotzer, T. V., Hellkamp, A. S., Zimmerman, J., Sweeney, M. O., Yee, R., Marinchak, R., Cook, J., Paraschos, A., Love, J., Radoslovich, G., et al. (2003) · Circulation · doi:10.1161/01.cir.0000057981.70380.45 · Cited by 750
Stroke with intermittent atrial fibrillation: incidence and predictors during aspirin therapy
Hart, R. G., Pearce, L. A., Rothbart, R. M., McAnulty, J. H., Asinger, R. W., & Halperin, J. L. (2000) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00489-1 · Cited by 663
Varma, N., Epstein, A. E., Irimpen, A., Schweikert, R., & Love, C. (2010) · Circulation · doi:10.1161/circulationaha.110.937409 · Cited by 594
Long-term risk of recurrent atrial fibrillation as documented by an implantable monitoring device
Israel, C. W., Grönefeld, G., Ehrlich, J. R., Li, Y.-G., & Hohnloser, S. H. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.08.027 · Cited by 480
Capucci, A., Santini, M., Padeletti, L., Gulizia, M., Botto, G., Boriani, G., Ricci, R., Favale, S., Zolezzi, F., Di Belardino, N., et al. (2005) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.07.044 · Cited by 401
BOTTO, G. L., PADELETTI, L., SANTINI, M., CAPUCCI, A., GULIZIA, M., ZOLEZZI, F., FAVALE, S., MOLON, G., RICCI, R., BIFFI, M., et al. (2009) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01320.x · Cited by 380
Daoud, E. G., Glotzer, T. V., Wyse, D. G., Ezekowitz, M. D., Hilker, C., Koehler, J., & Ziegler, P. D. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2011.04.022 · Cited by 326
LAZARUS, A. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00595.x · Cited by 228
Hoppe, U. C., Casares, J. M., Eiskjær, H., Hagemann, A., Cleland, J. G. F., Freemantle, N., & Erdmann, E. (2006) · Circulation · doi:10.1161/circulationaha.106.614560 · Cited by 203
Accuracy of Atrial Tachyarrhythmia Detection in Implantable Devices with Arrhythmia Therapies
PURERFELLNER, H., GILLIS, A. M., HOLBROOK, R., & HETTRICK, D. A. (2004) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2004.00569.x · Cited by 162 · cited 1×
“95% sensitivity and specificity for the detection of atrial tachycardia/atrial fibrillation (AT/AF) episodes and measurements of AT/AF burden.(6) Patients were included in the analysis if the total detected AHRE burden in a 24 h period exceeded an accumulative total of 14 min.”
BackgroundPOLLAK, W. M., SIMMONS, J. D., INTERIAN, A., ATAPATTU, S. A., CASTELLANOS, A., MYERBURG, R. J., & MITRANI, R. D. (2001) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2001.00424.x · Cited by 155 · cited 1×
“Previously published data suggest that excluding episodes ,5 min reduces the chance of oversensing.(23) Also, the inclusion requirement of .”
BackgroundSantini, M., Gasparini, M., Landolina, M., Lunati, M., Proclemer, A., Padeletti, L., Catanzariti, D., Molon, G., Botto, G. L., La Rocca, L., et al. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.08.624 · Cited by 121 · cited 4×
“However, Santini et al.(12) have recently demonstrated similar adverse outcome data to our study with the use of continuous device diagnostics in 1193 patients in sinus rhythm with CRT.”
ResultInfluentialIp, J. E., Waldo, A. L., Lip, G. Y. H., Rothwell, P. M., Martin, D. T., BERSOHN, M. M., Choucair, W. K., Akar, J. G., Wathen, M. S., Rohani, P., et al. (2009) · American Heart Journal · doi:10.1016/j.ahj.2009.07.002 · Cited by 118 · cited 1×
“We eagerly await the results of the ongoing interventional prospective multi-centre study of remote monitoring of AF, which should provide the strongest evidence for the role of anticoagulation.(21) In the worldwide survey, Lazarus retrospectively analysed 3 million transmissions in over 11 000 patients with brady pac…”
BackgroundSchaer, B. A., Zellweger, M. J., Cron, T. A., Kaiser, C. A., & Osswald, S. (2004) · Stroke · doi:10.1161/01.str.0000117568.07678.4b · Cited by 87
Left atrial mechanical function after brief duration atrial fibrillation
SPARKS, P. B., Shenthar, J., Mond, H. G., Vohra, J. K., Grigg, L., & Kalman, J. M. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00585-3 · Cited by 72
Clinical importance of new-onset atrial fibrillation after cardiac resynchronization therapy
Borleffs, C. J. W., Ypenburg, C., van Bommel, R. J., Delgado, V., van Erven, L., Schalij, M. J., & Bax, J. J. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.12.017 · Cited by 67 · cited 3×
“The significantly increased admissions for decompensated HF observed in Groups 1A and 2 compared with those with no prior history of AF who remained in sinus rhythm throughout the follow-up period (Group 1B) may be explained by Borleffs et al.(11) observation that patients with newly detected AF post-CRT-D, had less r…”
BackgroundMethodCaldwell, J. C., Contractor, H., Petkar, S., Ali, R., Clarke, B., Garratt, C. J., Neyses, L., & Mamas, M. A. (2009) · EP Europace · doi:10.1093/europace/eup201 · Cited by 54 · cited 4×
“did not demonstrate significant difference in outcomes between patients in sinus rhythm or newly detected PAF.(10) In a subsequent study by Borleff et al.”
MethodResultInfluentialSaxon, L. A. (2006) · Heart Rhythm · doi:10.1016/j.hrthm.2006.12.026 · Cited by 10
Cited by
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000041 · Cited by 7,115
2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.03.022 · Cited by 2,955
Antithrombotic Therapy for Atrial Fibrillation
Lip, G. Y. H., Banerjee, A., Boriani, G., Chiang, C. E., Fargo, R., Freedman, B., Lane, D. A., Ruff, C. T., Turakhia, M., Werring, D., et al. (2018) · Chest · doi:10.1016/j.chest.2018.07.040 · Cited by 939
Halcox, J. P. J., Wareham, K., Cardew, A., Gilmore, M., Barry, J. P., Phillips, C., & Gravenor, M. B. (2017) · Circulation · doi:10.1161/circulationaha.117.030583 · Cited by 580
Screening for Atrial Fibrillation: A Report of the AF-SCREEN International Collaboration
Freedman, B., Camm, J., Calkins, H., Healey, J. S., Rosenqvist, M., Wang, J., Albert, C. M., Anderson, C. S., Antoniou, S., Benjamin, E. J., et al. (2017) · Circulation · doi:10.1161/circulationaha.116.026693 · Cited by 537
Metadata
- Authors
- Shanmugam, N., Boerdlein, A., Proff, J., Ong, P., Valencia, O., Maier, S. K. G., Bauer, W. R., Paul, V., & Sack, S.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-09-20
- Volume
- 14
- Issue
- 2
- Pages
- 230-237
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2058658939
- Cited by
- 182
- References
- 23
- FWCI
- 8.00
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.