Remote, Wireless, Ambulatory Monitoring of Implantable Pacemakers, Cardioverter Defibrillators, and Cardiac Resynchronization Therapy Systems: Analysis of a Worldwide Database

LAZARUS, ARNAUD·2007·Pacing and Clinical Electrophysiology

Abstract

Study Objective: To describe the daily routine application of a new telemonitoring system in a large population of cardiac device recipients. Methods: Data transmitted daily and automatically by a remote, wireless Home Monitoring™ system (HM) were analyzed. The average time gained in the detection of events using HM versus standard practice and the impact of HM on physician workload were examined. The mean interval between device interrogations was used to compare the rates of follow‐up visits versus that recommended in guidelines. Results: 3,004,763 transmissions were made by 11,624 recipients of pacemakers (n = 4,631), defibrillators (ICD; n = 6,548), and combined ICD + cardiac resynchronization therapy (CRT‐D) systems (n = 445) worldwide. The duration of monitoring/patient ranged from 1 to 49 months, representing 10,057 years. The vast majority (86%) of events were disease‐related. The mean interval between last follow‐up and occurrence of events notified by HM was 26 days, representing a putative temporal gain of 154 and 64 days in patients usually followed at 6‐ and 3‐month intervals, respectively. The mean numbers of events per patient per month reported to the caregivers for the overall population was 0.6. On average, 47.6% of the patients were event‐free. The mean interval between follow‐up visits in patients with pacemakers, single‐chamber ICDs, dual chamber ICDs, and CRT‐D systems were 5.9 ± 2.1, 3.6 ± 3.3, 3.3 ± 3.5, and 1.9 ± 2.9 months, respectively. Conclusions: This broad clinical application of a new monitoring system strongly supports its capability to improve the care of cardiac device recipients, enhance their safety, and optimize the allocation of health resources.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1540-8159.2007.00595.x

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 228

Metadata

Authors
LAZARUS, A.
Venue
Pacing and Clinical Electrophysiology
Publisher
Wiley
Published
2007-01
Volume
30
Issue
s1
Pages
S2-S12
ISSN
  • 0147-8389 (ISSN-L)
  • 1540-8159
OpenAlex
W2167547881
Cited by
228
References
6
FWCI
12.96
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Remote, Wireless, Ambulatory Monitoring of Implantable Pacemakers, Cardioverter Defibrillators, and Cardiac Resynchronization Therapy Systems: Analysis of a Worldwide Database. https://app.cochat.ai/papers/10.1111/j.1540-8159.2007.00595.x
The paper
LAZARUS, A. (2007). Remote, Wireless, Ambulatory Monitoring of Implantable Pacemakers, Cardioverter Defibrillators, and Cardiac Resynchronization Therapy Systems: Analysis of a Worldwide Database. Pacing and Clinical Electrophysiology. https://doi.org/10.1111/j.1540-8159.2007.00595.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.