Evaluating strict and conventional left bundle branch block criteria using electrocardiographic simulations
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
AIMS: Left bundle branch block (LBBB) is a critical predictor of patient benefit from cardiac resynchronization therapy (CRT), but recent studies suggest that one-third of patients diagnosed with LBBB by conventional electrocardiographic (ECG) criteria may have a false-positive diagnosis. In this study, we tested the hypothesis that recently proposed strict LBBB ECG criteria improve specificity in cases of left ventricular hypertrophy (LVH) /dilatation and incomplete LBBB. METHODS AND RESULTS: We developed five heart models based on a healthy male with increasing degrees of LV hypertrophy and/or dilation. With each model, we simulated six conduction types: normal conduction, four increments of delayed initiation of LV activation (incomplete LBBB), and complete LBBB. Simulated ECGs were evaluated for the presence of LBBB by conventional (LV conduction delay and QRSd ≥120 ms) and strict ECG criteria (LV conduction delay, QRSd ≥140 ms men or ≥130 ms women, and mid-QRS notching in at least two of the leads I, aVL, V1, V2, V5, and/or V6). Both conventional and strict LBBB criteria had 100% sensitivity. However, conventional criteria falsely diagnosed LBBB in cases with LVH + LV dilated 10 mm, LVH or LV dilated 10 mm combined with LV initiation ≥6 ms after the right ventricle (RV), and with LV dilated 5 mm combined with LV initiation ≥12 ms after RV (48% specificity). Strict LBBB criteria resulted in no false positives (100% specificity). CONCLUSIONS: New strict LBBB criteria increase the specificity of complete LBBB diagnosis in the presence of LV hypertrophy/dilatation and incomplete LBBB, which is critical for selecting CRT patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
ACC/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities
Epstein, A. E., DiMarco, J. P., Ellenbogen, K. A., Estes, N. A. M., Freedman, R. A., Gettes, L. S., Gillinov, A. M., Gregoratos, G., Hammill, S. C., Hayes, D. L., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.02.032 · Cited by 2,546
Adelstein, E. C., & Saba, S. (2009) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2008.08.069 · Cited by 110
Research works printed but not linked: 34
- Mehra, 2004, Journal of the American College of Cardiology, 43, 1145, 10.1016/j.jacc.2003.10.050 · DOI
- Strickberger, 2005, Circulation, 111, 2146, 10.1161/01.CIR.0000161276.09685.4A · DOI · Paper page
- Rickard, 2010, 7, 885, 10.1016/j.hrthm.2010.04.005 · DOI
- 2004, Circulation, 109, 1133, 10.1161/01.CIR.0000118502.91105.F6 · DOI · Paper page
- 2011, Circulation, 123, 1061, 10.1161/CIRCULATIONAHA.110.960898 · DOI · Paper page
- Mascioli, 2012, Pacing and clinical electrophysiology : PACE, 35, 927, 10.1111/j.1540-8159.2012.03427.x · DOI
- Bacharova, 2011, Journal of electrocardiology, 44, 768, 10.1016/j.jelectrocard.2011.03.007 · DOI
- Strauss, 2011, Journal of electrocardiology, 44, 282, 10.1016/j.jelectrocard.2010.12.165 · doi:10.1016/j.jelectrocard.2010.12.165
- Bleeker, 2004, Journal of cardiovascular electrophysiology, 15, 544, 10.1046/j.1540-8167.2004.03604.x · DOI · Paper page
- Molhoek, 2004, Pacing and clinical electrophysiology : PACE, 27, 308, 10.1111/j.1540-8159.2004.00433.x · DOI · Paper page
- Strauss, 2011, The American journal of cardiology, 107, 927, 10.1016/j.amjcard.2010.11.010 · DOI · Paper page
- 1930, American heart journal, 5, 720, 10.1016/S0002-8703(30)90088-9 · doi:10.1016/s0002-8703(30)90088-9
- Grant, 1956, The American journal of medicine, 20, 834, 10.1016/0002-9343(56)90204-2 · doi:10.1016/0002-9343(56)90204-2
- Vassallo, 1984, Circulation, 69, 914, 10.1161/01.CIR.69.5.914 · DOI · Paper page
- Loring, 2011, Journal of electrocardiology, 44, 544, 10.1016/j.jelectrocard.2011.06.008 · DOI
- van Oosterom, 2004, Heart, 90, 165, 10.1136/hrt.2003.014662 · doi:10.1136/hrt.2003.014662
- 2011, 38, 657
- Lang, 2005, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography, 18, 1440, 10.1016/j.echo.2005.10.005 · DOI · Paper page
- DURRER, 1970, Circulation, 41, 899, 10.1161/01.CIR.41.6.899 · DOI · Paper page
- Surawicz, 2009, Journal of the American College of Cardiology, 53, 976, 10.1016/j.jacc.2008.12.013 · DOI · Paper page
- Mart nez, 2004, IEEE transactions on bio-medical engineering, 51, 570, 10.1109/TBME.2003.821031 · DOI · Paper page
- Zaca, 2011, The international journal of cardiovascular imaging, 27, 51, 10.1007/s10554-010-9651-y · doi:10.1007/s10554-010-9651-y
- 2009, Europace, 11, v93, 10.1093/europace/eup274 · DOI
- McAlister, 2007, JAMA, 297, 2502, 10.1001/jama.297.22.2502 · DOI · Paper page
- Hammill, 2010, 7, 1340, 10.1016/j.hrthm.2010.07.015 · DOI
- 2010, Circulation, 122, 2022, 10.1161/CIRCULATIONAHA.110.956011 · DOI · Paper page
- Potse, 2009, Medical & biological engineering & computing, 47, 719, 10.1007/s11517-009-0472-x · doi:10.1007/s11517-009-0472-x
- Wei, 1995, IEEE transactions on bio-medical engineering, 42, 343, 10.1109/10.376128 · DOI
- Galeotti, 2009, Journal of electrocardiology, 42, 204, 10.1016/j.jelectrocard.2008.12.007 · doi:10.1016/j.jelectrocard.2008.12.007
- van Huysduynen, 2005, 2, 1286, 10.1016/j.hrthm.2005.08.031 · DOI
- Van Huysduynen, 2005, Journal of cardiovascular electrophysiology, 16, 1097, 10.1111/j.1540-8167.2005.40758.x · doi:10.1111/j.1540-8167.2005.40758.x
- Kesek, 2009, Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc, 14, 185, 10.1111/j.1542-474X.2009.00294.x · DOI
- Arthur, 2011, IEEE transactions on bio-medical engineering, 58, 1565, 10.1109/TBME.2010.2104322 · DOI
- 2010, Europace, 12, 1526, 10.1093/europace/euq392 · DOI · Paper page
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Quarteroni, A., Lassila, T., Rossi, S., & Ruiz-Baier, R. (2017) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2016.05.031 · Cited by 248
“Electrophysiological simulations of the LBBB condition have also shown changes in the associated electrocardiograms when hypertrophy and dilation are considered [245].”
BackgroundKusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.037 · Cited by 131
Marcu, D. T. M., Adam, C. A., Dorobanțu, D.-M., Șalaru, D. L., Sascău, R. A., Balasanian, M. O., Macovei, L., Arsenescu-Georgescu, C., & Stătescu, C. (2022) · Medicina · doi:10.3390/medicina58020320 · Cited by 6
Metadata
- Authors
- Galeotti, L., van Dam, P. M., Loring, Z., Chan, D., & Strauss, D. G.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-05-23
- Volume
- 15
- Issue
- 12
- Pages
- 1816-1821
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W1998889830
- Cited by
- 67
- References
- 2
- FWCI
- 3.81
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluating strict and conventional left bundle branch block criteria using electrocardiographic simulations. https://app.cochat.ai/papers/10.1093/europace/eut132
- The paper
- Galeotti, L., van Dam, P. M., Loring, Z., Chan, D., & Strauss, D. G. (2013). Evaluating strict and conventional left bundle branch block criteria using electrocardiographic simulations. Europace. https://doi.org/10.1093/europace/eut132
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.