Feasibility, safety, and short-term outcome of leadless ultrasound-based endocardial left ventricular resynchronization in heart failure patients: results of the Wireless Stimulation Endocardially for CRT (WiSE-CRT) study
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
AIMS: Left ventricular (LV) endocardial pacing may address the limitations in the selection of an LV pacing site and provide improvements in cardiac resynchronization therapy (CRT) effectiveness. We report on the feasibility, the safety, and the short-term outcome of a leadless ultrasound-based technology for LV endocardial resynchronization in heart failure (HF) patients enroled into the Wireless Stimulation Endocardially for CRT (WiSE-CRT) study. METHODS AND RESULTS: Seventeen HF patients were enroled and categorized as: (i) patients in whom attempted coronary sinus lead implantation for CRT had failed (n = 7); (ii) patients with a previously implanted CRT device, not responding to CRT (n = 2); and (iii) patients with previously implanted pacemakers or implantable cardioverter-defibrillator and meeting the standard indications for CRT (n = 8). System implantation was achieved in 13 patients (76.5%); mean R-wave amplitude was 5.6 ± 3.2 mV and the mean pacing threshold was 1.6 ± 1.0 V, respectively. In one patient, no sufficient pacing thresholds were found; in three patients pericardial effusion occurred. Biventricular pacing was recorded in 83% and 92% of the patients at 1 month and 6 months, respectively. QRS duration was shorter during biventricular pacing compared with right ventricular pacing at 1 month (-41 ms; P = 0.0002) and 6 months (-42 ms; P = 0.0011), respectively. At the 6-month follow-up, two-thirds of the patients had at least one functional class change. Left ventricular ejection fraction significantly increased (P < 0.01) by 6 points at the 6-month follow-up. CONCLUSION: The feasibility of providing an endocardial stimulation for CRT with a leadless technology was successfully demonstrated. Despite the promising results for a novel technology, further study is required to definitively conclude the safety and the performance of the system. CLINICAL TRIAL REGISTRATION INFORMATION: NCT01294527.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Auricchio, A., Delnoy, P.-P., Regoli, F., Seifert, M., Markou, T., Butter, C., & for the collaborative study group (2013) · Europace · doi:10.1093/europace/eut124 · Cited by 94
Self-citation
Cited by
Permanent Leadless Cardiac Pacemaker Therapy: A Comprehensive Review
Tjong, F. V. Y., & Reddy, V. Y. (2017) · Circulation · doi:10.1161/circulationaha.116.025037 · Cited by 228
Cardiac Resynchronization Therapy With Wireless Left Ventricular Endocardial Pacing
Reddy, V. Y., Miller, M. A., Neuzil, P., Søgaard, P., Butter, C., Seifert, M., Delnoy, P. P., van Erven, L., Schalji, M., Boersma, L. V. A., et al. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.02.059 · Cited by 214
“Specifically, the WiSE-CRT study was stopped after only 17 patients because of a very high incidence of pericardial tamponade (n 1⁄4 3; 18%), which was fatal in 1 patient (15).”
BackgroundSelf-citationState of the art of leadless pacing
Sperzel, J., Burri, H., Gras, D., Tjong, F. V. Y., Knops, R. E., Hindricks, G., Steinwender, C., & Defaye, P. (2015) · Europace · doi:10.1093/europace/euv096 · Cited by 81
Leadless pacemakers: leading us into the future?: Figure 1
Mela, T., & Singh, J. P. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv261 · Cited by 13
“Although in its current form the ‘Micra’ has a self-contained battery, leadless pacing of the left ventricle has been demonstrated with the use of external ultrasound energy.(8) Alternative energy sources, i.”
BackgroundStrocchi, M., Wijesuriya, N., Elliott, M. K., Gillette, K., Neic, A., Mehta, V., Vigmond, E. J., Plank, G., Rinaldi, C. A., & Niederer, S. A. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.1049214 · Cited by 8
“, Sunnyvale, CA) is the only commercially available leadless LV pacing system (Auricchio et al., 2014).”
BackgroundMethodResultInfluential
Metadata
- Authors
- Auricchio, A., Delnoy, P.-P., Butter, C., Brachmann, J., Van Erven, L., Spitzer, S., Moccetti, T., Seifert, M., Markou, T., Laszo, K., Regoli, F., for the Collaborative Study Group, Ramos, M. A., Pasotti, E., Scopigni, F., Ramos, M. A., Hagne, C., Siclari, F., Demertzis, S., Sinha, A., Schalji, M., Wellens, H. J. J., Padeletti, L., & Van Hemel, N.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-02-04
- Volume
- 16
- Issue
- 5
- Pages
- 681-688
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2033278990
- Cited by
- 190
- References
- 1
- FWCI
- 15.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Feasibility, safety, and short-term outcome of leadless ultrasound-based endocardial left ventricular resynchronization in heart failure patients: results of the Wireless Stimulation Endocardially for CRT (WiSE-CRT) study. https://app.cochat.ai/papers/10.1093/europace/eut435
- The paper
- Auricchio, A., Delnoy, P.-P., Butter, C., Brachmann, J., Van Erven, L., Spitzer, S., Moccetti, T., Seifert, M., Markou, T., Laszo, K., Regoli, F., for the Collaborative Study Group, Ramos, M. A., Pasotti, E., Scopigni, F., Ramos, M. A., Hagne, C., Siclari, F., Demertzis, S., . . . Van Hemel, N. (2014). Feasibility, safety, and short-term outcome of leadless ultrasound-based endocardial left ventricular resynchronization in heart failure patients: results of the Wireless Stimulation Endocardially for CRT (WiSE-CRT) study. Europace. https://doi.org/10.1093/europace/eut435
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.