CoChat

Feasibility, safety, and short-term outcome of leadless ultrasound-based endocardial left ventricular resynchronization in heart failure patients: results of the Wireless Stimulation Endocardially for CRT (WiSE-CRT) study

Open access
Auricchio, A., Delnoy, P.-P., Butter, C., Brachmann, J., Van Erven, L., Spitzer, S., Moccetti, T., Seifert, M., Markou, T., Laszo, K., Regoli, F., for the Collaborative Study Group, Ramos, M. A., Pasotti, E., Scopigni, F., Ramos, M. A., Hagne, C., Siclari, F., Demertzis, S., Sinha, A., Schalji, M., Wellens, H. J. J., Padeletti, L., Van Hemel, N. · 2014 · Europace
Cited by 190

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

AIMS: Left ventricular (LV) endocardial pacing may address the limitations in the selection of an LV pacing site and provide improvements in cardiac resynchronization therapy (CRT) effectiveness. We report on the feasibility, the safety, and the short-term outcome of a leadless ultrasound-based technology for LV endocardial resynchronization in heart failure (HF) patients enroled into the Wireless Stimulation Endocardially for CRT (WiSE-CRT) study. METHODS AND RESULTS: Seventeen HF patients were enroled and categorized as: (i) patients in whom attempted coronary sinus lead implantation for CRT had failed (n = 7); (ii) patients with a previously implanted CRT device, not responding to CRT (n = 2); and (iii) patients with previously implanted pacemakers or implantable cardioverter-defibrillator and meeting the standard indications for CRT (n = 8). System implantation was achieved in 13 patients (76.5%); mean R-wave amplitude was 5.6 ± 3.2 mV and the mean pacing threshold was 1.6 ± 1.0 V, respectively. In one patient, no sufficient pacing thresholds were found; in three patients pericardial effusion occurred. Biventricular pacing was recorded in 83% and 92% of the patients at 1 month and 6 months, respectively. QRS duration was shorter during biventricular pacing compared with right ventricular pacing at 1 month (-41 ms; P = 0.0002) and 6 months (-42 ms; P = 0.0011), respectively. At the 6-month follow-up, two-thirds of the patients had at least one functional class change. Left ventricular ejection fraction significantly increased (P < 0.01) by 6 points at the 6-month follow-up. CONCLUSION: The feasibility of providing an endocardial stimulation for CRT with a leadless technology was successfully demonstrated. Despite the promising results for a novel technology, further study is required to definitively conclude the safety and the performance of the system. CLINICAL TRIAL REGISTRATION INFORMATION: NCT01294527.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/europace/eut435

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 190

Metadata

Authors
Auricchio, A., Delnoy, P.-P., Butter, C., Brachmann, J., Van Erven, L., Spitzer, S., Moccetti, T., Seifert, M., Markou, T., Laszo, K., Regoli, F., for the Collaborative Study Group, Ramos, M. A., Pasotti, E., Scopigni, F., Ramos, M. A., Hagne, C., Siclari, F., Demertzis, S., Sinha, A., Schalji, M., Wellens, H. J. J., Padeletti, L., & Van Hemel, N.
Venue
Europace
Published
2014-02-04
Volume
16
Issue
5
Pages
681-688
ISSN
  • 1099-5129 (ISSN-L)
  • 1532-2092
OpenAlex
W2033278990
Cited by
190
References
1
FWCI
15.58
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Feasibility, safety, and short-term outcome of leadless ultrasound-based endocardial left ventricular resynchronization in heart failure patients: results of the Wireless Stimulation Endocardially for CRT (WiSE-CRT) study. https://app.cochat.ai/papers/10.1093/europace/eut435
The paper
Auricchio, A., Delnoy, P.-P., Butter, C., Brachmann, J., Van Erven, L., Spitzer, S., Moccetti, T., Seifert, M., Markou, T., Laszo, K., Regoli, F., for the Collaborative Study Group, Ramos, M. A., Pasotti, E., Scopigni, F., Ramos, M. A., Hagne, C., Siclari, F., Demertzis, S., . . . Van Hemel, N. (2014). Feasibility, safety, and short-term outcome of leadless ultrasound-based endocardial left ventricular resynchronization in heart failure patients: results of the Wireless Stimulation Endocardially for CRT (WiSE-CRT) study. Europace. https://doi.org/10.1093/europace/eut435

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.