Implementation and reimbursement of remote monitoring for cardiac implantable electronic devices in Europe: a survey from the health economics committee of the European Heart Rhythm Association
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) permits early detection of arrhythmias, device, and lead failure and may also be useful in risk-predicting patient-related outcomes. Financial benefits for patients and healthcare organizations have also been shown. We sought to assess the implementation and funding of RM of CIEDs, including conventional pacemakers (PMs), implantable cardioverter defibrillators (ICDs), and cardiac resynchronization therapy (CRT) devices in Europe. Electronic survey from 43 centres in 15 European countries. In the study sample, RM was available in 22% of PM patients, 74% of ICD patients, and 69% of CRT patients. The most significant perceived benefits were the early detection of atrial arrhythmias in pacemaker patients, lead failure in ICD patients, and worsening heart failure in CRT patients. Remote monitoring was reported to lead a reduction of in-office follow-ups for all devices. The most important reported barrier to the implementation of RM for all CIEDs was lack of reimbursement (80% of centres). Physicians regard RM of CIEDs as a clinically useful technology that affords significant benefits for patients and healthcare organizations. Remote monitoring, however, is perceived as increasing workload. Reimbursement for RM is generally perceived as a major barrier to implementation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Varma, N., Epstein, A. E., Irimpen, A., Schweikert, R., & Love, C. (2010) · Circulation · doi:10.1161/circulationaha.110.937409 · Cited by 594
The CONNECT (Clinical Evaluation of Remote Notification to Reduce Time to Clinical Decision) Trial
Crossley, G. H., Boyle, A., Vitense, H., Chang, Y., & Mead, R. H. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.12.012 · Cited by 526
Saxon, L. A., Hayes, D. L., Gilliam, F. R., Heidenreich, P. A., Day, J., Seth, M., Meyer, T. E., Jones, P. W., & Boehmer, J. P. (2010) · Circulation · doi:10.1161/circulationaha.110.960633 · Cited by 515 · cited 1×
“In the ALTITUDE registry, involving 263 562 CIED patients, RM was associated with a 50% lower mortality, compared with usual care.(9) In contrast, when implantable diagnostic tools are linked to an audible patient alert without connection to a RM system, the risk for hospitalization may increase.”
A randomized trial of long-term remote monitoring of pacemaker recipients (The COMPAS trial)
Mabo, P., Victor, F., Bazin, P., Ahres, S., Babuty, D., Da Costa, A., Binet, D., & Daubert, J.-C. (2012) · European Heart Journal · doi:10.1093/eurheartj/ehr419 · Cited by 347 · cited 1×
“A reduction in the risk of hospitalization for atrial arrhythmias or stroke was observed in the COMPAS trial.(6) In the ALTITUDE registry, involving 263 562 CIED patients, RM was associated with a 50% lower mortality, compared with usual care.”
BackgroundLandolina, M., Perego, G. B., Lunati, M., Curnis, A., Guenzati, G., Vicentini, A., Parati, G., Borghi, G., Zanaboni, P., Valsecchi, S., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.088971 · Cited by 344
Raatikainen, M. J. P., Uusimaa, P., van Ginneken, M. M. E., Janssen, J. P. G., & Linnaluoto, M. (2008) · Europace · doi:10.1093/europace/eun203 · Cited by 189 · cited 1×
“It has been proposed that avoidance of traditional, in-office visits for CIED monitoring translates into financial benefits for patients and healthcare organizations.(7,8) This survey was undertaken by the Health Economic Committee of the European Heart Rhythm Association to assess the implementation and reimbursement…”
Background
Cited by
Jacob, C., Sanchez-Vazquez, A., & Ivory, C. (2020) · JMIR mHealth and uHealth · doi:10.2196/15935 · Cited by 292
Klersy, C., Boriani, G., De Silvestri, A., Mairesse, G. H., Braunschweig, F., Scotti, V., Balduini, A., Cowie, M. R., Leyva, F., & for the Health Economics Committee of the European Heart Rhythm Association (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.470 · Cited by 120
Self-citationRemote monitoring of chronic diseases: a landscape assessment of policies in four European countries
Rojahn, K., Laplante, S., Sloand, J., Main, C., Ibrahim, A., Wild, J., Sturt, N., Areteou, T., & Johnson, K. I. (2016) · PLoS ONE · doi:10.1371/journal.pone.0155738 · Cited by 54
Boriani, G., Burri, H., Svennberg, E., Imberti, J. F., Merino, J. L., & Leclercq, C. (2022) · EP Europace · doi:10.1093/europace/euac118 · Cited by 51
“Local policies and specifically the practice of reimbursement deserve a special focus, since in the survey promoted by EHRA and reported by Mairesse et al.(19) in 2015 the lack of reimbursement was reported as the most important barrier to full implementation of RM from around 58% to 72% of centres.”
BackgroundResultInfluential
Metadata
- Authors
- Mairesse, G. H., Braunschweig, F., Klersy, K., Cowie, M. R., & Leyva, F.
- Venue
- EP Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-02-20
- Volume
- 17
- Issue
- 5
- Pages
- 814-818
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2121926561
- Cited by
- 81
- References
- 6
- FWCI
- 5.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Implementation and reimbursement of remote monitoring for cardiac implantable electronic devices in Europe: a survey from the health economics committee of the European Heart Rhythm Association. https://app.cochat.ai/papers/10.1093/europace/euu390
- The paper
- Mairesse, G. H., Braunschweig, F., Klersy, K., Cowie, M. R., & Leyva, F. (2015). Implementation and reimbursement of remote monitoring for cardiac implantable electronic devices in Europe: a survey from the health economics committee of the European Heart Rhythm Association. EP Europace. https://doi.org/10.1093/europace/euu390
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.