The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Cost-effectiveness of mass screening for untreated atrial fibrillation using intermittent ECG recording
Abstract
AIMS: The aim of this study was to estimate the cost-effectiveness of 2 weeks of intermittent screening for asymptomatic atrial fibrillation (AF) in 75/76-year-old individuals. METHODS AND RESULTS: The cost-effectiveness analysis of screening in 75-year-old individuals was based on a lifelong decision analytic Markov model. In this model, 1000 hypothetical individuals, who matched the population of the STROKESTOP study, were simulated. The population was analysed for different parameters such as prevalence, AF status, treatment with oral anticoagulation, stroke risk, utility, and costs. In the base-case scenario, screening of 1000 individuals resulted in 263 fewer patient-years with undetected AF. This implies eight fewer strokes, 11 more life-years, and 12 more quality-adjusted life years (QALYs) per 1000 screened individuals. The screening implies an incremental cost of €50 012, resulting in a cost of €4313 per gained QALY and €6583 per avoided stroke. CONCLUSIONS: With the use of a decision analytic simulation model, it has been shown that screening for asymptomatic AF in 75/76-year-old individuals is cost-effective.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Opportunistic screening for silent AF seems cost-effective in elderly populations (e.g.> 65 years), 131 and similar effects have been reported using single-lead ECG screening in other at-risk populations.132,133”
From 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS (2016) · cites this paper as [132]
Citations
Cites
Dabigatran versus warfarin in patients with atrial fibrillation
Connolly, S. J., Ezekowitz, M. D., Yusuf, S., Eikelboom, J., Oldgren, J., Parekh, A., Pogue, J., Reilly, P. A., Themeles, E., Varrone, J., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0905561 · Cited by 11,215
Rivaroxaban versus warfarin in nonvalvular atrial fibrillation
Patel, M. R., Mahaffey, K. W., Garg, J., Pan, G., Singer, D. E., Hacke, W., Breithardt, G., Halperin, J. L., Hankey, G. J., Piccini, J. P., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1009638 · Cited by 9,430
Apixaban versus warfarin in patients with atrial fibrillation
Granger, C. B., Alexander, J. H., McMurray, J. J. V., Lopes, R. D., Hylek, E. M., Hanna, M., Al-Khalidi, H. R., Ansell, J., Atar, D., Avezum, A., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1107039 · Cited by 8,943
Atrial fibrillation as an independent risk factor for stroke: the Framingham study
Wolf, P. A., Abbott, R. D., & Kannel, W. B. (1991) · Stroke · doi:10.1161/01.str.22.8.983 · Cited by 7,388
Guidelines for the management of atrial fibrillation
Authors/Task Force Members, Camm, A. J., Kirchhof, P. F., Lip, G. Y. H., Schotten, U., Savelieva, I., Ernst, S., Gelder, I. C. V., Al‐Attar, N., Hindricks, G., et al. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq278 · Cited by 5,924
Hart, R. G., Pearce, L. A., & Aguilar, M. I. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-12-200706190-00007 · Cited by 4,793
2012 focused update of the ESC Guidelines for the management of atrial fibrillation
Authors Task Force Members, Camm, A. J., Lip, G. Y. H., Caterina, R. D., Savelieva, I., Atar, D., Hohnloser, S. H., Hindricks, G., Kirchhof, P. F., Bax, J. J., et al. (2012) · EP Europace · doi:10.1093/europace/eus305 · Cited by 3,823
Cryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161
Subclinical atrial fibrillation and the risk of stroke
Healey, J. S., Connolly, S. J., Gold, M. R., Israel, C. W., Van Gelder, I. C., Capucci, A., Lau, C. P., Fain, E., Yang, S., Bailleul, C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1105575 · Cited by 2,100
Prevalence, incidence and lifetime risk of atrial fibrillation: the Rotterdam study
Heeringa, J., van der Kuip, D. A. M., Hofman, A., Kors, J. A., van Herpen, G., Stricker, B. H. C., Stijnen, T., Lip, G. Y. H., & Witteman, J. C. M. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi825 · Cited by 1,939
Flagged first, then by citations
Cited by
Sorted by citations
Items 101–154 of 154
Sciera, L. K., Frost, L., Dybro, L., & Poulsen, P. B. (2020) · European Heart Journal - Quality of Care and Clinical Outcomes · doi:10.1093/ehjqcco/qcaa092 · Cited by 9
Wahler, S., Birkemeyer, R., Alexopoulos, D. K., Siudak, Z., Müller, A., & von der Schulenburg, J.-M. (2022) · Health Economics Review · doi:10.1186/s13561-022-00362-2 · Cited by 8
Marston, H. R., Hadley, R., Banks, D., & Miranda-Duro, M. D. C. (2019) · doi:10.2196/preprints.13251 · Cited by 9
The budget impact of implementing atrial fibrillation-screening in European countries
Eklund, M., Bernfort, L., Appelberg, K., Engler, D., Schnabel, R. B., Martínez, C., Wallenhorst, C., Boriani, G., Buckley, C. M., Diederichsen, S. Z., et al. (2024) · European Heart Journal Supplements · doi:10.1093/eurheartjsupp/suae076 · Cited by 7
Intelligent algorithms powered smart devices for atrial fibrillation discrimination
Xie, L., Wang, L., Mo, D., Zhang, Z., & Liang, M. (2024) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2024.107480 · Cited by 7
Chen, Y., Hung, C., Huang, C., Hung, Y., Hwang, J., & Ho, Y. (2017) · JMIR mhealth and uhealth · doi:10.2196/mhealth.8290 · Cited by 7
Murray, M.-I. K. (2018) · Journal of Atrial Fibrillation · doi:10.4022/jafib.2069 · Cited by 6
Smartphone and new tools for atrial fibrillation diagnosis: evidence for clinical applicability
PAPACCIOLI, G., BASSI, G., Cecilia, L. U. G. I., Parente, E., D’ANDREA, A., PROIETTI, R., Imbalzano, E., TURKI, A. A., & Russo, V. (2022) · Minerva Cardiology and Angiology · doi:10.23736/s2724-5683.22.05841-0 · Cited by 7
Ramkumar, S., Pathan, F. K., Kawakami, H., Ochi, A., Yang, H., Potter, E. L., & Marwick, T. H. (2020) · International Journal of Cardiology · doi:10.1016/j.ijcard.2020.09.057 · Cited by 6
Introduction of Wearable Device in Cardiovascular Field for Monitoring Arrhythmia
Kim, N. H., & Ko, J. S. (2021) · Chonnam Medical Journal · doi:10.4068/cmj.2021.57.1.1 · Cited by 7
Can screening for atrial fibrillation be implemented at scale?
Lowres, N., Neubeck, L., & Freedman, S. B. (2016) · EP Europace · doi:10.1093/europace/euw030 · Cited by 7
Santala, O. E., Lipponen, J. A., Jäntti, H., Rissanen, T. T., Tarvainen, M. P., Väliaho, E., Rantula, O., Naukkarinen, N. S., Hartikainen, J. E. K., Martikainen, T. J., et al. (2023) · Cardiology in Review · doi:10.1097/crd.0000000000000526 · Cited by 10
Callanan, A., Bayat, F., Quinlan, D., Kearney, P. M., Buckley, C. M., Smith, S. M., & Bradley, C. (2023) · BJGP Open · doi:10.3399/bjgpo.2022.0110 · Cited by 6
Zaprutko, T., Florczak‐Wyspianska, J., Kopciuch, D., Paczkowska, A., Ratajczak, P., Dorszewska, J., Nowakowska, E., & Kus, K. (2021) · Healthcare · doi:10.3390/healthcare9080999 · Cited by 5
Approach to atrial fibrillation
Bell, A., Andrade, J. G., Macle, L., Connelly, K. A., LaBine, L., & Singer, A. G. (2023) · Canadian Family Physician · doi:10.46747/cfp.6904245 · Cited by 5
Boccalon, B., Foppa, M., Brant, L. C. C., Filho, M. M. P., Ribeiro, A. L. P., Duncan, B. B., & Santos, Â. B. S. (2025) · PubMed Central · doi:10.36660/abc.20240487 · Cited by 4
Opportunities and challenges of large-scale screening for atrial fibrillation
Zink, M. D., Marx, N., Crijns, H. J. G. M., & Schotten, U. (2018) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-017-0550-y · Cited by 4
A Lightweight Unidimensional Deep Learning Model for Atrial Fibrillation Detection
Soares, Q. B., Monteiro, R., Jatene, F. B., & Gutierrez, M. A. (2022) · Computing in cardiology · doi:10.22489/cinc.2022.220 · Cited by 4
Almanac 2015: atrial fibrillation research in Heart
Qamar, M. J. U., & Kirchhof, P. F. (2016) · Heart · doi:10.1136/heartjnl-2015-307809 · Cited by 4
Antonio, R. S., Guasch, E., Tolosana, J. M., & Mont, L. (2018) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2019.1550720 · Cited by 4
Screening for Atrial Fibrillation and the Role of Digital Health Technologies
Richardson, E., Hall, A., & Mitchell, A. R. J. (2019) · IntechOpen eBooks · doi:10.5772/intechopen.88660 · Cited by 4
Atrial Fibrillation Population Screening
Gruwez, H., Proesmans, T., Evens, S., Verbrugge, F. H., Deferm, S., Dauw, J., Willems, R., Vandervoort, P. M., Haemers, P., & Pison, L. (2021) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2021.04.009 · Cited by 5
The catch in atrial fibrillation detection: don't forget to treat
Duncker, D., & Svennberg, E. (2021) · The Lancet Healthy Longevity · doi:10.1016/s2666-7568(21)00176-8 · Cited by 4
Himmelreich, J. C. L., Harskamp, R. E., Geelhoed, B., Virdone, S., Lucassen, W. A. M., Gansevoort, R. T., & Rienstra, M. (2022) · BMJ Open · doi:10.1136/bmjopen-2021-057476 · Cited by 3
Bonander, C., Jakobsson, N., Gudmundsdottir, K. K., Svennberg, E., & Engdahl, J. (2025) · EP Europace · doi:10.1093/europace/euaf030 · Cited by 3
Ghazal, F., Aronsson, M., Al-Khalili, F., Rosenqvist, M., & Levin, L. (2022) · Scandinavian Cardiovascular Journal · doi:10.1080/14017431.2022.2060523 · Cited by 3
Zaprutko, T., Zaprutko, J., Sprawka, J., Pogodzińska, M., Michalak, M., Paczkowska, A., Kus, K., Nowakowska, E., & Baszko, A. (2021) · Cardiology Journal · doi:10.5603/cj.a2021.0083 · Cited by 3
Should This Patient Be Screened for Atrial Fibrillation?
Burns, R. B., ZIMETBAUM, P. J., Lubitz, S. A., & Smetana, G. W. (2019) · Annals of Internal Medicine · doi:10.7326/m19-1126 · Cited by 3
Liu, W., Lin, C., Lin, C., Lin, T., Lin, W., Lee, C., Chang, C., Tsai, C., Hung, Y.-J., & Hsieh, P.-H. (2025) · Journal of Medical Systems · doi:10.1007/s10916-025-02287-9 · Cited by 2
Optimizing atrial fibrillation management using a novel patient-level computational model.
Cai, M., Barrios-Espinosa, C., Rienstra, M., Crijns, H., Schotten, U., & Heijman, J. (2025) · i Medicina · doi:10.1016/j.medj.2025.100896 · Cited by 3
Patel, S., Kongnakorn, T., Nikolaou, A., Javaid, Y., & Mokgokong, R. (2023) · Journal of Medical Economics · doi:10.1080/13696998.2023.2179210 · Cited by 2
The mC2HEST Score for Incident Atrial Fibrillation
Li, Y., Li, Q., Wang, L., Zhang, T., Gao, H., Pastori, D., Liang, Z., Lip, G. Y. H., & Wang, Y. (2025) · JACC Advances · doi:10.1016/j.jacadv.2024.101521 · Cited by 4
Bakır, E. O., Yurdam, F. S., Dolu, A. K., & Agüloglu, S. (2025) · The International Journal of Cardiovascular Imaging · doi:10.1007/s10554-025-03512-9 · Cited by 2
Remote detection of arrhythmias using Apple watch: A useful wearable during COVID-19 pandemic
Jariwala, P. V., & Jadhav, K. P. (2021) · IHJ Cardiovascular Case Reports (CVCR) · doi:10.1016/j.ihjccr.2021.05.002 · Cited by 2
Prevalence and predictors of subclinical atrial fibrillation in hospitalized older adults
Spannella, F., Giulietti, F., Pimpini, L., Lombardi, F. E., Re, S., Schiavi, P., Dragano, G., Antonicelli, R., & Sarzani, R. (2021) · Aging · doi:10.18632/aging.203270 · Cited by 2
Cost-Effectiveness of Atrial Fibrillation Screening Strategies: A Systematic Review
Gorji, H. A., Khosravi, M., Mahmoodi, R., Hasoumi, M., Souresrafil, A., Alipour, V., Rezapour, A., Hajahmadi, M., & Azari, S. (2023) · Iranian Journal of Public Health · doi:10.18502/ijph.v52i4.12435 · Cited by 2
Lee, J., Kim, T., Park, J., Joung, B., & Choi, E. (2021) · Korean Journal of Medicine · doi:10.3904/kjm.2021.96.2.76 · Cited by 1
Challenges and Opportunities for Atrial Fibrillation Management
Cai, M., & Heijman, J. (2025) · Cardiology Discovery · doi:10.1097/cd9.0000000000000155 · Cited by 1
Costos asociados a la fibrilación auricular
Díaz-Martínez, J. C., Duque-Ramírez, M., Marín-Velásquez, J. E., Aristizábal, J. M., Velásquez-Vélez, J. E., & Uribe, W. (2016) · Revista Colombiana de Cardiología · doi:10.1016/j.rccar.2016.10.029 · Cited by 1
Is Screening for Atrial Fibrillation and Its Risk Factors Useful and Cost-Effective?
Sandhu, R. K., & Healey, J. S. (2021) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2020.10.009 · Cited by 1
Даценко, І. С., & Кабачна, А. В. (2022) · Farmatsevtychnyi zhurnal · doi:10.32352/0367-3057.5.22.06 · Cited by 1
Cai, M., Espinosa, C. B., Rienstra, M., Crijns, H., Schotten, U., & Heijman, J. (2024) · medRxiv · doi:10.1101/2024.09.30.24314669 · Cited by 1
Left-to-right shunt induced by an active fixation electrode
Lux, Á., Osztheimer, I., & Merkely, B. P. (2016) · EP Europace · doi:10.1093/europace/euw240
Screening for atrial fibrillation in high-risk individuals : a stroke preventive effort
Svennberg, E. (2016) · Figshare
Poorthuis, M. H. F. (2021) · doi:10.33540/79
Lee, J., Kim, T., Park, J., Joung, B., & Choi, E. (2021) · Korean Journal of Medicine · doi:10.3904/kjm.2021.96.3.252
Berkemeier, E. A. (2022) · Monitor Versorgungsforschung · doi:10.24945/mvf.02.22.1866-0533.2396
Boccalon, B., Foppa, M., Brant, L. C. C., Filho, M. M. P., Ribeiro, A. L. P., Duncan, B. B., & Santos, Â. B. S. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4871403
Souliotis, K. N., Golna, C., Gountas, I., Trafalis, D. T., Barmpouni, M., & Vemmos, K. N. (2024) · Cardiology and cardiovascular medicine. · doi:10.5772/intechopen.1006642
Lewis, J. E. A., Tozer, J., Lobban, T., Evans, A., Banner, M., & Ambrose, L. (2025) · Journal of Foot and Ankle Research · doi:10.1002/jfa2.70043
Wahler, S., Birkemeyer, R., Alexopoulos, D., Siudak, Z., Müller, A., & von der Schulenburg, J.-M. (2022) · Figshare · doi:10.6084/m9.figshare.19243509
Mckenzie, K., Freedman, B., Jacob, A., Modi, R. N., & Lowres, N. (2026) · BMJ Open · doi:10.1136/bmjopen-2025-109404
Metadata
- Authors
- Aronsson, M., Svennberg, E., Rosenqvist, M., Engdahl, J., Al-Khalili, F., Friberg, L., Frykman-Kull, V., & Levin, L.-Å.
- Affiliations
- Linköping University (SE)
- Danderyds sjukhus (SE)
- Hallands sjukhus Halmstad (SE)
- Corresponding author
- Aronsson, Mattias
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-04-12
- Volume
- 17
- Issue
- 7
- Pages
- 1023-1029
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2160206914
- Cited by
- 154
- References
- 48
- Citations by year
- 2026: 2 · 2025: 8 · 2024: 7 · 2023: 9 · 2022: 13 · 2021: 21 · 2020: 15 · 2019: 28 · 2018: 14 · 2017: 16 · 2016: 19 · 2015: 2
- FWCI
- 12.36
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- EP Europace (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Atrial Fibrillation Management and Outcomes
- Social Sciences › Economics, Econometrics and Finance › Economics and Econometrics › Health Systems, Economic Evaluations, Quality of Life
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Health Promotion and Cardiovascular Prevention
- Keywords
- atrial fibrillation, mass screening, asymptomatic atrial fibrillation, cost-effectiveness, older adults, stroke prevention, oral anticoagulation, quality-adjusted life years
- MeSH terms
- Aged, Atrial Fibrillation, Cost-Benefit Analysis, Electrocardiography, Female, Humans, Male, Mass Screening, Quality of Life, Sweden, Prevalence, Survival Rate, Health Care Costs, Risk Assessment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review