Outcomes of catheter ablation of atrial fibrillation in patients with hypertrophic cardiomyopathy: a systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
AIMS: Over the past decade, catheter ablation (CA) has become an established therapy for symptomatic atrial fibrillation (AF). Atrial fibrillation is common in hypertrophic cardiomyopathy (HCM) patients, and restoring sinus rhythm is of great clinical benefit to them. Therefore, we conducted a systematic review and meta-analysis of the available data to evaluate the effectiveness and safety of CA for AF in patients with HCM. METHODS AND RESULTS: Six databases were searched to identify studies describing outcomes of CA of AF in HCM patients with a mean follow-up of ≥12 months after the index procedure. The following data were extracted: (i) single-procedure success, (ii) multiple-procedure success, and (iii) drug-free success. Fifteen studies involving 531 patients were included. Single-procedure freedom from atrial arrhythmia at the latest follow-up was 45.5% [95% confidence interval (CI): 34.8-56.2%]. With multiple procedures, the final success rate was 66.1% (95% CI: 55.3-76.9%) overall, 71.8% (95% CI: 61.6-82.0%) in paroxysmal AF, and 47.5% (95% CI: 36.0-59.0%) in non-paroxysmal AF. Without anti-arrhythmic drugs (AADs), single-procedure success rate at latest follow-up was 32.9% (95% CI: 21.7-41.1%); after multiple procedures, this raised to 50.4% (95% CI: 39.2-61.6%). The incidence of serious periprocedural complications was acceptable [5.1% (95% CI: 2.8-9.6%)]. Substantial heterogeneity (I(2)> 50%) was noted in the above groups. CONCLUSIONS: Catheter ablation of AF in patients with HCM is feasible, although more repeat procedures and AAD are needed to prevent AF recurrence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852
January, C. T., Wann, L. S., Alpert, J. S., Calkins, H., Cigarroa, J. E., Cleveland, J. C., Conti, J. B., Ellinor, P. T., Ezekowitz, M. D., Field, M. E., et al. (2014) · Circulation · doi:10.1161/cir.0000000000000040 · Cited by 2,056
Wilber, D. J., Pappone, C., Neuzil, P., De Paola, A., Marchlinski, F., Natale, A., Macle, L., Daoud, E. G., Calkins, H., Hall, B., et al. (2010) · JAMA · doi:10.1001/jama.2009.2029 · Cited by 1,170 · cited 5×
“The principal findings were that: (i) a single ablation procedure was insufficient to achieve freedom from atrial arrhythmia for the cohorts studied (,50% with AAD assistance); (ii) over time, multiple procedures were required to achieve control of AF, which was achieved in 66.1% of the cases at final follow-up; (iii)…”
MethodInfluentialGanesan, A. N., Shipp, N. J., Brooks, A. G., Kuklik, P., Lau, D. H., Lim, H. S., Sullivan, T., Roberts‐Thomson, K. C., & Sanders, P. (2013) · Journal of the American Heart Association · doi:10.1161/jaha.112.004549 · Cited by 800 · cited 5×
“The results of our study are consistent with these previous data.(10,32,33) Mechanisms of recurrence Eight studies(14,16,17,19,23,24,26,27) involved the information about PV reconnection in repeat ablations (40–100%).”
BackgroundMethodResultInfluentialHakalahti, A., Biancari, F., Nielsen, J. C., & Raatikainen, M. J. P. (2015) · Europace · doi:10.1093/europace/euu376 · Cited by 191
Wynn, G. J., Das, M., Bonnett, L. J., Panikker, S., Wong, T., & Gupta, D. (2014) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.114.001759 · Cited by 146
Di Donna, P., Olivotto, I., Delcre, S. D. L., Caponi, D., Scaglione, M., Nault, I., Montefusco, A., Girolami, F., Cecchi, F., Haissaguerre, M., et al. (2010) · Europace · doi:10.1093/europace/euq013 · Cited by 138 · cited 1×
“Structural or electrical characteristics of the LA were found to be the most important factor for AF recurrence after ablation.(13,17,20,23) – 25,27 In three studies,(17,18,25) maximum LV wall thickness failed to show a statistical association with radiofrequency CA outcome.”
BackgroundDagres, N., Varounis, C., Gaspar, T., Piorkowski, C., Eitel, C., Iliodromitis, E. K., Lekakis, J. P., Flevari, P., Simeonidou, E., Rallidis, L. S., et al. (2011) · Journal of Cardiac Failure · doi:10.1016/j.cardfail.2011.07.009 · Cited by 133
Chambers, D., Rodgers, M., & Woolacott, N. (2009) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2008.12.010 · Cited by 121 · cited 2×
“Study quality was assessed using a modified version of previously published quality assessment criteria for case series.(11) Study quality was limited and the majority of studies had identifiable limitations in their study design (see Supplementary material online, Appendix S2).”
MethodBUNCH, T. J., MUNGER, T. M., FRIEDMAN, P. A., ASIRVATHAM, S. J., BRADY, P. A., CHA, Y., REA, R. F., SHEN, W., POWELL, B. D., OMMEN, S. R., et al. (2008) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2008.01192.x · Cited by 109
Cited by
2023 ESC guidelines for the management of cardiomyopathies
Arbelo, E., Protonotarios, A., Gimeno, J. R., Arbustini, E., Barriales-Villa, R., Basso, C., Bezzina, C. R., Biagini, E., Blom, N. A., de Boer, R. A., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad194 · Cited by 2,844
Ommen, S. R., Mital, S., Burke, M. A., Day, S. M., Deswal, A., Elliott, P., Evanovich, L. L., Hung, J., Joglar, J. A., Kantor, P., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.08.044 · Cited by 994
Ommen, S. R., Ho, C. Y., Asif, I. M., Balaji, S., Burke, M. A., Day, S. M., Dearani, J. A., Epps, K. C., Evanovich, L., Ferrari, V. A., et al. (2024) · Circulation · doi:10.1161/cir.0000000000001250 · Cited by 807
2020 AHA/ACC Guideline for the Diagnosis and Treatment of Patients With Hypertrophic Cardiomyopathy
Ommen, S. R., Mital, S., Burke, M. A., Day, S. M., Deswal, A., Elliott, P., Evanovich, L. L., Hung, J., Joglar, J. A., Kantor, P., et al. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2020.08.045 · Cited by 643
Tzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Sepehri Shamloo, A., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Europace · doi:10.1093/europace/euae043 · Cited by 634
Metadata
- Authors
- Zhao, D.-S., Shen, Y., Zhang, Q., Lin, G., Lu, Y.-H., Chen, B.-T., Shi, L.-S., Huang, J.-F., & Lu, H.-H.
- Venue
- Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-11-26
- Volume
- 18
- Issue
- 4
- Pages
- 508-520
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2270474049
- Cited by
- 86
- References
- 11
- FWCI
- 0.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Outcomes of catheter ablation of atrial fibrillation in patients with hypertrophic cardiomyopathy: a systematic review and meta-analysis. https://app.cochat.ai/papers/10.1093/europace/euv339
- The paper
- Zhao, D.-S., Shen, Y., Zhang, Q., Lin, G., Lu, Y.-H., Chen, B.-T., Shi, L.-S., Huang, J.-F., & Lu, H.-H. (2016). Outcomes of catheter ablation of atrial fibrillation in patients with hypertrophic cardiomyopathy: a systematic review and meta-analysis. Europace. https://doi.org/10.1093/europace/euv339
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.