The benefit of pacemaker therapy in patients with neurally mediated syncope and documented asystole: a meta-analysis of implantable loop recorder studies
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Aim: Although the efficacy of cardiac pacing in patients with neurally mediated syncope (NMS) and documented asystole is established, a more robust point estimate of the benefit, which is not possible with any individual study, is lacking. Methods and results: We undertook a meta-analysis of individual participant data from four studies that reported follow-up data on syncope recurrence with cardiac pacing in patients with NMS who had had an electrocardiographic (ECG) documentation of an asystolic event by means of implantable loop recorder (ILR). Of a total of 1046 patients, who had ILR implanted, 383 (36.6%) patients had an ECG documentation of a diagnostic event during mean follow-up of 13 ± 10 months. Of these, 201 (52%) patients, corresponding to 19.2% of the total ILRs, had an asystolic event of 12.8 ± 11.0 s duration documented and met the criteria for pacemaker therapy. Follow-up was available in 121 (60%) of those patients with asystolic events. Syncope recurred after pacing in 18 (14.9%) patients with an actuarial rate of 13% [95% confidence interval (CI) ±6] at 1 year, 21% (95%CI ±10) at 2 years, and 24% (95%CI ±11) at 3 years. On multivariable Cox regression analysis, positive tilt test response was the only significant predictor of syncope recurrence with a hazard ratio (95% CI) of 4.3 (1.4-13). On the contrary, type of asystolic event (sinus arrest or atrioventricular block), prodrome, cardiac abnormalities, number and duration of history of syncope, age, and gender were not predictors of recurrence of syncope. Conclusion: A long asystolic pause, suitable for pacemaker therapy, was found in one of five patients with ILR. After pacemaker implantation, most of these patients remained free of syncope recurrence for up to 3 years. The benefit of pacemaker was greater in patients with negative tilt test.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“On the contrary, patients with a positive tilt test response will have a higher risk of recurrence of syncope with a large confidence range, which makes any estimate of the benefit of pacing uncertain.”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [309]
In the citing paper
“In a meta-analysis 309 of individual patient data from four studies performed in patients with asystolic reflex syncope documented by an ILR, the estimated 3-year recurrence rate of syncope was 2% (95% CI ± 4%) in tilt-negative patients and 33% (95% CI ± 20%) in tilt-positive patients; a positive tilt test response was the only significant predictor of syncope recurrence with a hazard ratio of 4.3”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [309]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Developed in collaboration with, European Heart Rhythm Association (EHRA), Heart Failure Association (HFA), and Heart Rhythm Society (HRS), societies, E. B. T. F., European Society of Emergency Medicine (EuSEM), European Federation of Internal Medicine (EFIM), European Union Geriatric Medicine Society (EUGMS), American Geriatrics Society (AGS), European Neurological Society (ENS), et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp298 · Cited by 2,040
Self-citationBrignole, M., Menozzi, C., Moya, A., Andresen, D., Blanc, J. J., Krahn, A. D., Wieling, W., Beiras, X., Deharo, J. C., Russo, V., et al. (2012) · Circulation · doi:10.1161/circulationaha.111.082313 · Cited by 437
Self-citationBrignole, M., Sutton, R., Menozzi, C., Garcia-Civera, R., Moya, A., Wieling, W., Andresen, D., Benditt, D. G., & Vardas, P. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi842 · Cited by 376
Self-citationIndications for the use of diagnostic implantable and external ECG loop recorders
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, et al. (2009) · Europace · doi:10.1093/europace/eup097 · Cited by 362
Self-citationEdvardsson, N., Frykman, V., van Mechelen, R., Mitro, P., Mohii-Oskarsson, A., Pasquie, J.-L., Ramanna, H., Schwertfeger, F., Ventura, R., Voulgaraki, D., et al. (2011) · Europace · doi:10.1093/europace/euq418 · Cited by 250 · cited 4×
“Age (years), mean (SD) 64 (10) 65 (13) 0.”
InfluentialThe clinical impact of implantable loop recorders in patients with syncope
Farwell, D. J., Freemantle, N., & Sulke, N. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehi602 · Cited by 219 · cited 3×
“Mean duration of follow-up (months), mean (SD) 13 (10) – 14 (9) –”
Fludrocortisone for the Prevention of Vasovagal Syncope
Sheldon, R., Raj, S. R., Rose, M. S., Morillo, C. A., Krahn, A. D., Medina, E., Talajic, M., Kus, T., Seifer, C. M., Lelonek, M., et al. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.04.030 · Cited by 155
Sutton, R., & Brignole, M. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu255 · Cited by 127
Self-citationBrignole, M., Ammirati, F., Arabia, F., Quartieri, F., Tomaino, M., Ungar, A., Lunati, M., Russo, V., Del Rosso, A., & Gaggioli, G. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv069 · Cited by 80 · cited 4×
“Asystolic response >_3 s 100 (11)* 30 (18)* 16 (16) 14 (21)”
InfluentialSelf-citationBrignole, M., Arabia, F., Ammirati, F., Tomaino, M., Quartieri, F., Rafanelli, M., Del Rosso, A., Rita Vecchi, M., Russo, V., & Gaggioli, G. (2016) · Europace · doi:10.1093/europace/euv343 · Cited by 76
Self-citationStop vasodepressor drugs in reflex syncope: a randomised controlled trial
Solari, D., Tesi, F., Unterhuber, M., Gaggioli, G., Ungar, A., Tomaino, M., & Brignole, M. (2017) · Heart · doi:10.1136/heartjnl-2016-309865 · Cited by 68 · cited 2×
“Age (years), mean (SD) 66 (13) 66 (13) 66 (14) 66 (13)”
Self-citationImplications of mechanism of bradycardia on response to pacing in patients with unexplained syncope
Sud, S., Klein, G. J., Skanes, A. C., Gula, L. J., Yee, R., & Krahn, A. D. (2007) · EP Europace · doi:10.1093/europace/eum020 · Cited by 66
Mechanism of syncope without prodromes with normal heart and normal electrocardiogram
Brignole, M., Guieu, R., Tomaino, M., Iori, M., Ungar, A., Bertolone, C., Unterhuber, M., Bottoni, N., Tesi, F., & Claude Deharo, J. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2016.08.046 · Cited by 59
Self-citationUngar, A., Sgobino, P., Russo, V., Vitale, E., Sutton, R., Melissano, D., Beiras, X., Bottoni, N., Ebert, H. H., Gulizia, M., et al. (2013) · Heart · doi:10.1136/heartjnl-2013-304399 · Cited by 58 · cited 1×
“Asystolic response >_3 s 100 (11)* 30 (18)* 16 (16) 14 (21)”
Self-citationSyncope in patients paced for atrioventricular block
Aste, M., Oddone, D., Donateo, P., Solano, A., Maggi, R., Croci, F., Solari, D., & Brignole, M. (2016) · Europace · doi:10.1093/europace/euv425 · Cited by 35
Self-citationCourse of symptoms and spontaneous ECG in pacemaker patients: a 5-year follow-up study
LANGENFELD, H., GRIMM, W., MAISCH, B., & KOGHSIEK, K. (1988) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.1988.tb05986.x · Cited by 30 · cited 3×
“Age (years), mean (SD) 66 (13) 66 (13) 66 (14) 66 (13)”
Research works printed but not linked: 1
- Moya, 2009, Guidelines for the diagnosis and management of syncope (version 2009), Eur Heart J, 30, 2631
Cited by
2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., de Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martín, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy037 · Cited by 1,951
Self-citation
Metadata
- Authors
- Brignole, M., Deharo, J. C., Menozzi, C., Moya, A., Sutton, R., Tomaino, M., & Ungar, A.
- Affiliations
- Department of Cardiology, Arrhythmologic Centre, Ospedali del Tigullio, Via Don Bobbio 25, Lavagna, Italy
- Department of Cardiology, Hopital La Timone Adultes, 264 Rue Saint-Pierre, Marseille cedex 5, France
- Department of Cardiology, Arcispedale S. Maria Nuova, Viale Risorgimento 80, Reggio Emilia, Italy
- Department of Cardiology, Hospital Universitario Vall d’Hebron, Paseo valle d'Ebron 119-129, Barcelona, Spain
- Department of Cardiology, National Heart and Lung Institute, Imperial College, South Kensington Campus, London, UK
- Department of Cardiology, Ospedale di Bolzano, Via Lorenz Bohler 5, Bolzano, Italy
- Department of Cardiology, University of Florence, AOU Careggi, Viale Pieraccini 6, Florence, Italy
- Venue
- EP Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2017-12-15
- Volume
- 20
- Issue
- 8
- Pages
- 1362-1366
- ISSN
- 1099-5129
- 1532-2092
- Cited by
- 39
- References
- 16
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.