Comparing the performance of artificial intelligence and conventional diagnosis criteria for detecting left ventricular hypertrophy using electrocardiography
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Aims: Although left ventricular hypertrophy (LVH) has a high incidence and clinical importance, the conventional diagnosis criteria for detecting LVH using electrocardiography (ECG) has not been satisfied. We aimed to develop an artificial intelligence (AI) algorithm for detecting LVH. Methods and results: This retrospective cohort study involved the review of 21 286 patients who were admitted to two hospitals between October 2016 and July 2018 and underwent 12-lead ECG and echocardiography within 4 weeks. The patients in one hospital were divided into a derivation and internal validation dataset, while the patients in the other hospital were included in only an external validation dataset. An AI algorithm based on an ensemble neural network (ENN) combining convolutional and deep neural network was developed using the derivation dataset. And we visualized the ECG area that the AI algorithm used to make the decision. The area under the receiver operating characteristic curve of the AI algorithm based on ENN was 0.880 (95% confidence interval 0.877–0.883) and 0.868 (0.865–0.871) during the internal and external validations. These results significantly outperformed the cardiologist’s clinical assessment with Romhilt-Estes point system and Cornell voltage criteria, Sokolov-Lyon criteria, and interpretation of ECG machine. At the same specificity, the AI algorithm based on ENN achieved 159.9%, 177.7%, and 143.8% higher sensitivities than those of the cardiologist’s assessment, Sokolov-Lyon criteria, and interpretation of ECG machine. Conclusion: An AI algorithm based on ENN was highly able to detect LVH and outperformed cardiologists, conventional methods, and other machine learning techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LeCun, Y., Bengio, Y., & Hinton, G. (2015) · Nature · doi:10.1038/nature14539 · Cited by 84,126
Statistical Modeling: The Two Cultures (with comments and a rejoinder by the author)
Breiman, L. (2001) · Statistical Science · doi:10.1214/ss/1009213726 · Cited by 4,340
Attia, Z. I., Kapa, S., Lopez-Jimenez, F., McKie, P. M., Ladewig, D. J., Satam, G., Pellikka, P. A., Enriquez-Sarano, M., Noseworthy, P. A., Munger, T. M., et al. (2019) · Nature Medicine · doi:10.1038/s41591-018-0240-2 · Cited by 1,389
Cited by
Kumar, Y., Koul, A., Singla, R., & Ijaz, M. F. (2023) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-021-03612-z · Cited by 1,040
RetractedECG Monitoring Systems: Review, Architecture, Processes, and Key Challenges
Serhani, M. A., T. El Kassabi, H., Ismail, H., & Nujum Navaz, A. (2020) · Sensors · doi:10.3390/s20061796 · Cited by 357
Deep learning and the electrocardiogram: review of the current state-of-the-art
Somani, S., Russak, A. J., Richter, F., Zhao, S., Vaid, A., Chaudhry, F., De Freitas, J. K., Naik, N., Miotto, R., Nadkarni, G. N., et al. (2021) · EP Europace · doi:10.1093/europace/euaa377 · Cited by 264
Liu, C.-M., Shih, E. S. C., Chen, J.-Y., Huang, C.-H., Wu, I.-C., Chen, P.-F., Higa, S., Yagi, N., Hu, Y.-F., Hwang, M.-J., et al. (2022) · JACC: Asia · doi:10.1016/j.jacasi.2022.02.008 · Cited by 46
“Recently, researchers have successfully trained artificial intelligence (AI) models to correlate electrocardiogram (ECG) signals to echocardiographic phenotypes and automatically screen for cardiac structural derangement (eg, cardiac contractile dysfunction, hypertrophy).(13,14) Using the same approach, a semiautomati…”
BackgroundDeep learning to detect left ventricular structural abnormalities in chest X-rays
Bhave, S., Rodriguez, V., Poterucha, T., Mutasa, S., Aberle, D., Capaccione, K. M., Chen, Y., Dsouza, B., Dumeer, S., Goldstein, J., et al. (2024) · European Heart Journal · doi:10.1093/eurheartj/ehad782 · Cited by 38
Metadata
- Authors
- Kwon, J.-M., Jeon, K.-H., Kim, H. M., Kim, M. J., Lim, S. M., Kim, K.-H., Song, P. S., Park, J., Choi, R. K., & Oh, B.-H.
- Venue
- EP Europace
- Publisher
- Oxford University Press (OUP)
- Published
- 2019-12-04
- Volume
- 22
- Issue
- 3
- Pages
- 412-419
- ISSN
- 1099-5129 (ISSN-L)
- 1532-2092
- OpenAlex
- W2994403349
- Cited by
- 118
- References
- 3
- FWCI
- 8.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparing the performance of artificial intelligence and conventional diagnosis criteria for detecting left ventricular hypertrophy using electrocardiography. https://app.cochat.ai/papers/10.1093/europace/euz324
- The paper
- Kwon, J.-M., Jeon, K.-H., Kim, H. M., Kim, M. J., Lim, S. M., Kim, K.-H., Song, P. S., Park, J., Choi, R. K., & Oh, B.-H. (2020). Comparing the performance of artificial intelligence and conventional diagnosis criteria for detecting left ventricular hypertrophy using electrocardiography. EP Europace. https://doi.org/10.1093/europace/euz324
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.