CoChat

Comparative evaluation of two density gradient preparations for sperm separation for medically assisted conception

Chen, M.-J. · 1999 · Human Reproduction
Cited by 83

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

To evaluate and optimize the sperm separation efficiency of a novel silane-coated silica bead (Puresperm), serial studies were carried out to compare the various sperm parameters between: (i) three-layer (90%-70%-40%) Puresperm and three-layer (90%-70%-40%) conventional polyvinylpyrrolidone (PVP)-coated silica bead (Percoll) gradients; (ii) three-layer (90%-70%-40%) and two-layer (90%-45%) Puresperm gradients and separately the same for Percoll; and (iii) large (3.0 ml) and small (0.75 ml) semen loading volumes on three-layer Puresperm gradients. Normozoospermic semen samples were treated and analysed in 12 replicates for each experiment. Manual evaluation of concentration, percentage motility, percentage vitality, percentage normal morphology; computer-assisted semen analysis evaluation of concentration, percentage motility, grade of motility, motion characteristics (curvilinear velocity, linearity, amplitude of lateral head velocity, beat cross frequency, percentage hyperactivation); and yields from the initial semen samples were compared. Percoll was found to be superior to Puresperm in concentration, percentage motility, percentage vitality and yields after three-layer density gradient centrifugation. There were no significant differences in sperm parameters between two- and three-layer Percoll gradients, but three-layer Puresperm gradients behaved significantly better than two-layer gradients. Large semen volume loads on three-layer Puresperm gradients resulted in greater sperm concentrations, percentage motility, percentage vitality and percentage normal morphology, but small semen volume loads produced greater yields of good-quality spermatozoa. In the light of Percoll being withdrawn from the shelf for the use of assisted reproduction because of the presence of PVP, three-layer Puresperm gradients with large semen loading volumes appear to be an attractive alternative for sperm separation in medically assisted conception.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/humrep/14.3.759

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

Metadata

Authors
Chen, M.-J.
Venue
Human Reproduction
Published
1999-03-01
Volume
14
Issue
3
Pages
759-764
ISSN
  • 0268-1161 (ISSN-L)
  • 1460-2350
OpenAlex
W2113661416
Cited by
83
References
2
FWCI
2.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.