CoChat

Three-dimensional ultrasonography in the diagnosis of deep endometriosis

Guerriero, S., Saba, L., Ajossa, S., Peddes, C., Angiolucci, M., Perniciano, M., Melis, G. B., Alcazar, J. L. · 2014 · Human Reproduction

The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.

Abstract

STUDY QUESTION: In the use of 'tenderness-guided' transvaginal ultrasound, is the diagnostic accuracy of three-dimensional (3D) ultrasonography better than two-dimensional (2D) ultrasonography in the identification of deep endometriosis? SUMMARY ANSWER: Three-dimensional ultrasonography has a significantly higher diagnostic accuracy in the diagnosis of posterior locations of deep endometriosis without intestinal involvement, such as the uterosacral ligaments, vaginal and rectovaginal endometriosis. WHAT IS KNOWN ALREADY: The only previous study of the diagnosis of posterior compartment endometriosis reported an poor sensitivity of 3D ultrasonography for uterosacral and sigmoid colon involvement. STUDY DESIGN, SIZE, DURATION: This diagnostic test study included 202 patients scheduled for surgery because of clinical suspicion of deep pelvic endometriosis and was carried out between January 2009 and September 2012. PARTICIPANTS/MATERIALS, SETTING, METHODS: Modified transvaginal ultrasonography was performed on all of the women by a single examiner. Two locations of deep endometriosis were considered: intestinal involvement and other posterior lesions (including vaginal location, rectovaginal septum and uterosacral ligaments). Once the 2D ultrasonography had been performed, the 3D acquisition was performed and the obtained volume was stored. To avoid the risk of recall bias, the same operator evaluated the 3D volumes 6 months after the last examination using virtual navigation to provide a presumptive diagnosis of the presence and localization of deep endometriosis. In addition, to evaluate the reproducibility of 3D, two operators with different levels of expertise performed a retrospective review of 3D volumes from a random sample of 35 patients, twice, 1 week apart to also assess intraobserver agreement. The diagnostic performance of both tests was expressed as area under the receiver-operating characteristics curve (AUC), sensitivity, specificity, positive and negative predictive values, positive (LR+) and negative (LR-) likelihood ratios, with their respective 95% confidence interval (CI). Reproducibility was evaluated using kappa statistics. MAIN RESULTS AND THE ROLE OF CHANCE: Surgery revealed deep endometriosis in 129 patients. The AUCs for endometriosis of intestinal location were similar for both ultrasound techniques. The AUCs for endometriosis of other posterior locations were significantly different (0.891, 95% CI 0.839-0.943 for 3D versus 0.789, 95% CI 0.720-0.858 for 2D; P = 0.0193). For the intestinal involvement, the specificity, sensitivity, positive and negative predictive value, and LR+ and LR- were 93% (89-95%), 95% (88-98%), 89% (83-92%), 97% (93-99%), 13, and 0.06, respectively, for 2D ultrasound and 97% (93-99%), 91% (84-94%), 95% (88-98%), 95% (91-96%), 25, and 0.09, respectively, for 3D ultrasound. For other posterior locations, the specificity, sensitivity, positive and negative predictive value, and LR+ and LR- were 88% (82-93%), 71% (64-77%), 83% (75-90%), 79% (74-83%), 6.10, 0.32, respectively, for 2D ultrasound and 94% (89-97%), 87% (81-91%), 92% (86-96%), 90% (85-93%), 14.0, 0.14, respectively, for 3D ultrasound. Intraobserver agreement was substantial for both examiners (kappa 0.8754, for operator A and 0.7087, for operator B, respectively). Interobserver agreement was also substantial. LIMITATIONS, REASONS FOR CAUTION: The disadvantages of 3D ultrasound to be considered are the necessity of newer ultrasonographic equipment and that fewer sonographers completely know the 3D technique. There are also some limitations within this study. First, an expert examiner performed the real-time ultrasound and 3D volume acquisitions. Second, the same operator also performed the 3D evaluations but at least 6 months after the last acquisition to avoid a possible recall bias. WIDER IMPLICATIONS OF THE FINDINGS: The diagnostic performance obtained in the present study is superior to the accuracy reported in other studies of 3D ultrasonography, but not superior to all other published articles of 2D ultrasonography. The reported high diagnostic accuracy of 3D ultrasound could be widely generalizable because good reproducibility was demonstrated even with an operator with less expertise. STUDY FUNDING/COMPETING INTEREST(S): This study was supported in part by the Regione Autonoma della Sardegna (project code CPR-24750).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/humrep/deu054

Cites

33 of 33 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 33 references

Research works printed but not linked: 8

  1. Abrao MS, Goncalves MO, Dias JA Jr, Podgaec S, Chamie LP, Blasbalg R. Comparison between clinical examination, transvaginal sonography and magnetic resonance imaging for the diagnosis of deep endometriosis. Hum Reprod 2007;22:3092 -3097.
  2. Alca ´zar JL, Iturra A, Sedda F, Auba ´M, Ajossa S, Guerriero S, Jurado M. Three-dimensional volume off-line analysis as compared to real-time ultrasound for assessing adnexal masses. Eur J Obstet Gynecol Reprod Biol 2012;161:92 -95.
  3. Fratelli N, Scioscia M, Bassi E, Musola M, Minelli L, Trivella G. Transvaginal sonography for preoperative assessment of deep endometriosis. J Clin Ultrasound 2013;41:69 -75.
  4. Guerriero S, Ajossa S, Gerada M, D'Aquila M, Piras B, Melis GB. 'Tenderness-guided' transvaginal ultrasonography: a new method for the detection of deep endometriosis in patients with chronic pelvic pain. Fertil Steril 2007;88:1293-1297.
  5. Guerriero S, Ajossa S, Gerada M, Virgilio B, Angioni S, Melis GB. Diagnostic value of transvaginal 'tenderness-guided' ultrasonography for the prediction of location of deep endometriosis. Hum Reprod 2008; 23:2452-2457.
  6. Guerriero S, Saba L, Ajossa S, Peddes C, Sedda F, Piras A, Olartecoechea B, Auba ´M, Alca ´zar JL. Assessing the reproducibility of the IOTA simple ultrasound rules for classifying adnexal masses as benign or malignant using stored 3D volumes. Eur J Obstet Gynecol Reprod Biol 2013b;171:157-160.
  7. Leo ´n M, Vaccaro H, Alca ´zar JL, Martinez J, Gutierrez J, Amor F, Iturra A, Sovino H. Extended transvaginal sonography in deep infiltrating endo- metriosis: use of bowel preparation and an acoustic window with intravaginal gel: preliminary results. J Ultrasound Med 2014;33:315-321.
  8. Piketty M, Chopin N, Dousset B, Millischer-Bellaische AE, Roseau G, Leconte M, Borghese B, Chapron C. Preoperative work-up for patients with deeply infiltrating endometriosis: transvaginal ultrasonography must definitely be the first-line imaging examination. Hum Reprod 2009; 24:602 -607.

Cited by

See all 64

Metadata

Authors
Guerriero, S., Saba, L., Ajossa, S., Peddes, C., Angiolucci, M., Perniciano, M., Melis, G. B., & Alcazar, J. L.
Affiliations
  • University of Cagliari (IT)
  • Azienda Ospedaliero-Universitaria Cagliari (IT)
Corresponding author
Guerriero, S.
Venue
Human Reproduction
Published
2014-03-23
Volume
29
Issue
6
Pages
1189-1198
ISSN
  • 0268-1161 (ISSN-L)
  • 1460-2350
OpenAlex
W2101299378
Cited by
59
References
33
Citations by year
2026: 4 · 2025: 8 · 2024: 3 · 2023: 4 · 2022: 9 · 2021: 2 · 2020: 5 · 2019: 3 · 2018: 4 · 2017: 6 · 2016: 6 · 2015: 4 · 2014: 1
FWCI
6.88
Type
journal article
Language
en
Open access
closed
Locations
  • Human Reproduction (publishedVersion)
  • PubMed (publishedVersion)
  • UNICA IRIS Institutional Research Information System (University of Cagliari) (submittedVersion)
Funders
Regione Autonoma della Sardegna (project code CPR-24750, CPR-24750)
Topics
  • Health Sciences › Medicine › Reproductive Medicine › Endometriosis Research and Treatment
  • Health Sciences › Medicine › Obstetrics and Gynecology › Gynecological conditions and treatments
  • Health Sciences › Medicine › Obstetrics and Gynecology › Ectopic Pregnancy Diagnosis and Management
Keywords
deep infiltrating endometriosis, three-dimensional ultrasonography, transvaginal ultrasound, diagnostic accuracy, uterosacral ligament, rectovaginal endometriosis, vaginal endometriosis, intestinal endometriosis, intraobserver reproducibility, virtual navigation, preoperative diagnosis
MeSH terms
Adolescent, Adult, Endometriosis, Female, Humans, Intestinal Diseases, Middle Aged, Prospective Studies, Retrospective Studies, Sensitivity and Specificity, Ultrasonography, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.