The Sick Building Syndrome (SBS) in Office Workers. A Case-Referent Study of Personal, Psychosocial and Building-Related Risk Indicators
The DOI matches its Crossref record.
Abstract
BACKGROUND: The Office Illness Project in Northern Sweden, comprising both a screening questionnaire study of 4943 office workers and a case-referent study of Sick Building Syndrome (SBS) in 464 subjects was recently completed. Previously published results from the survey showed that female gender asthma/rhinitis, high psychosocial work load, paper and visual display terminal (VDT) work were related to an increased prevalence of SBS symptoms. METHODS: The case-referent study presented in this paper used data from the questionnaire supplemented with information from a clinical examination, a survey of psychosocial factors at work building data from inspection and measurements taken at the work sites. RESULTS: Personal factors such as atopy and photosensitive skin, psychosocial conditions and physical exposure factors influencing indoor air quality (IAQ), such as outdoor air flow rates and the presence of photocopiers were related to an increased prevalence of the reported SBS symptoms. The results were established using multivariate analysis. CONCLUSIONS: The rate response relationship between actually measured ventilation rates and the prevalence of perceived SBS symptoms presents strong evidence for the association between IAQ factors and health.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876
Redlich, C. A., Sparer, J., & Cullen, M. R. (1997) · The Lancet · doi:10.1016/s0140-6736(96)07220-0 · Cited by 759
Ventilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740
Self-citationWargocki, P., Sundell, J., Bischof, W., Brundrett, G., Fanger, P. O., Gyntelberg, F., Hanssen, S. O., Harrison, P., Pickering, A., Seppänen, O., et al. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01145.x · Cited by 418
Self-citationSick building syndrome: Figure 1
Burge, P. S. (2004) · Occupational and Environmental Medicine · doi:10.1136/oem.2003.008813 · Cited by 345
Particle Emission Characteristics of Office Printers
He, C., Morawska, L., & Taplin, L. (2007) · Environmental Science & Technology · doi:10.1021/es063049z · Cited by 270
Quantitative relationship of sick building syndrome symptoms with ventilation rates
Fisk, W. J., Mirer, A. G., & Mendell, M. J. (2009) · Indoor Air · doi:10.1111/j.1600-0668.2008.00575.x · Cited by 196
“Equation 9 is not applicable for case-control data; therefore, the odds ratios from one study (Stenberg et al. 1994) were not converted to risk ratios.”
BackgroundMenzies, D., & Bourbeau, J. (1997) · New England Journal of Medicine · doi:10.1056/nejm199711203372107 · Cited by 167
Eczema Increases Susceptibility to PM10in Office Indoor Environments
Bakke, J. V., Wieslander, G., Norback, D., & Moen, B. E. (2012) · Archives of Environmental & Occupational Health · doi:10.1080/19338244.2011.564236 · Cited by 13
Metadata
- Authors
- STENBERG, B., ERIKSSON, N., HÖÖG, J., SUNDELL, J., & WALL, S.
- Venue
- International Journal of Epidemiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1994
- Volume
- 23
- Issue
- 6
- Pages
- 1190-1197
- ISSN
- 0300-5771 (ISSN-L)
- 1464-3685
- OpenAlex
- W2100077211
- Cited by
- 102
- References
- 0
- FWCI
- 2.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.