Randomized controlled trial of unflued gas heater replacement on respiratory health of asthmatic schoolchildren
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Previous studies do not provide a clear picture of the relationship between nitrogen dioxide (NO(2)) exposure and asthma. METHODS: Eighteen schools using unflued gas heating in winter were randomly allocated to either retain their heaters (10 control schools) or to have replacement flued gas or electric heaters installed at the beginning of winter (8 intervention schools). Fortnightly telephone interviews were used to record daily individual asthma symptoms that occurred over 12 weeks (including winter). Lung function and histamine challenge tests were performed at baseline and the end of the study. NO(2) was measured in each school classroom on 9 days and in each household on 3 days spread over the study period. RESULTS: From 199 primary school children that met the eligibility criteria, 45 intervention and 73 control children agreed to participate. Baseline characteristics were similar between groups. Difficulty breathing during the day (Relative Risk [RR] = 0.41; 95% CI: 0.07, 0.98) and night (RR = 0.32; 95% CI: 0.14, 0.69), chest tightness during the day (RR = 0.45; 95% CI: 0.25, 0.81), and daytime asthma attacks (RR = 0.39; 95% CI: 0.17, 0.93) were significantly reduced in the intervention group. Percentage predicted forced expiratory volume in one second (FEV(1)), the concentration of histamine inducing a 20% fall in FEV(1) (PD(20)), and the dose-response slope (DRS) were similar between groups at follow-up. Mean (standard deviation) NO(2) levels were 15.5 (6.6) parts per billion (ppb) and 47.0 (26.8) ppb in the intervention and control schools respectively (P < 0.001). CONCLUSIONS: Asthma symptoms were reduced following a replacement intervention that removed high exposure to NO(2). Such replacement should be considered a public health priority for schools using unflued gas heating during winter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid method for measurement of bronchial responsiveness.
Yan, K., Salome, C., & Woolcock, A. J. (1983) · Thorax · doi:10.1136/thx.38.10.760 · Cited by 758
Cited by
Impact of Air Pollution on Asthma Outcomes
Tiotiu, A. I., Novakova, P., Nedeva, D., Chong-Neto, H. J., Novakova, S., Steiropoulos, P., & Kowal, K. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17176212 · Cited by 513
Zheng, X.-Y., Ding, H., Jiang, L.-N., Chen, S.-W., Zheng, J.-P., Qiu, M., Zhou, Y.-X., Chen, Q., & Guan, W.-J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0138146 · Cited by 440
Kanchongkittiphon, W., Mendell, M. J., Gaffin, J. M., Wang, G., & Phipatanakul, W. (2015) · Environmental Health Perspectives · doi:10.1289/ehp.1307922 · Cited by 414
Hesterberg, T. W., Bunn, W. B., McClellan, R. O., Hamade, A. K., Long, C. M., & Valberg, P. A. (2009) · Critical Reviews in Toxicology · doi:10.3109/10408440903294945 · Cited by 287
Howden-Chapman, P., Pierse, N., Nicholls, S., Gillespie-Bennett, J., Viggers, H., Cunningham, M., Phipps, R., Boulic, M., Fjallstrom, P., Free, S., et al. (2008) · BMJ · doi:10.1136/bmj.a1411 · Cited by 278
Respiratory health and indoor air pollutants based on quantitative exposure assessments
Hulin, M., Simoni, M., Viegi, G., & Annesi-Maesano, I. (2012) · European Respiratory Journal · doi:10.1183/09031936.00159011 · Cited by 267
Asthma disparities in urban environments
Bryant-Stephens, T. (2009) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2009.04.030 · Cited by 210
“Other studies that have looked at nitrous oxide reduction successfully reduced school absences and asthma symptoms.(59,60) Most effective environmental strategies are comprehensive and multifaceted in nature.”
BackgroundHansel, N. N., Breysse, P. N., McCormack, M. C., Matsui, E. C., Curtin-Brosnan, J., Williams, D. L., Moore, J. L., Cuhran, J. L., & Diette, G. B. (2008) · Environmental Health Perspectives · doi:10.1289/ehp.11349 · Cited by 175
“To our knowledge, there has been only one previous trial specifically targeting NO2 (Pilotto et al. 2004).”
BackgroundAssociation of Indoor Nitrogen Dioxide Exposure with Respiratory Symptoms in Children with Asthma
Belanger, K., Gent, J. F., Triche, E. W., Bracken, M. B., & Leaderer, B. P. (2006) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200408-1123oc · Cited by 172
“A recent randomized trial provides strong evidence that reducing NO2 exposure results in a reduction of asthma symptoms (23).”
BackgroundInfluentialVentilation in public housing: implications for indoor nitrogen dioxide concentrations
Zota, A., Adamkiewicz, G., Levy, J. I., & Spengler, J. D. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2005.00375.x · Cited by 118
The respiratory health effects of nitrogen dioxide in children with asthma
Gillespie-Bennett, J., Pierse, N., Wickens, K., Crane, J., Howden-Chapman, P., & and the Housing Heating and Health Study Research Team (2011) · European Respiratory Journal · doi:10.1183/09031936.00115409 · Cited by 98
More effective home heating reduces school absences for children with asthma
Free, S., Howden-Chapman, P., Pierse, N., Viggers, H., & the Housing, H. A. H. S. R. T. (2010) · Journal of Epidemiology and Community Health · doi:10.1136/jech.2008.086520 · Cited by 80
Gillespie-Bennett, J., Pierse, N., Wickens, K., Crane, J., Nicholls, S., Shields, D., Boulic, M., Viggers, H., Baker, M., Woodward, A., et al. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2008.00554.x · Cited by 36
Metadata
- Authors
- Pilotto, L. S.
- Venue
- International Journal of Epidemiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-02-01
- Volume
- 33
- Issue
- 1
- Pages
- 208-211
- ISSN
- 0300-5771 (ISSN-L)
- 1464-3685
- OpenAlex
- W2166633435
- Cited by
- 105
- References
- 1
- FWCI
- 3.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.