Quantitative Culture of Intravenous Catheters and Other Intravascular Inserts
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Quantitative cultures were done on 149 intravenous catheters and 40 additional intravascular inserts. Intradermal and intravascular segments of the insert were cultured separately. The inserts were immersed in broth and flushed. The number of colony-forming units (cfu) per insert was estimated by surface culture of serial dilution of the broth. Nonquantitative culture of undiluted broth was also done. Since all inserts associated with bacteremia had at least 10(3) cfu, inserts greater than 10(3) cfu were considered infected. Staphylococcus epidermidis was more likely than more virulent organisms to colonize an insert without causing bacteremia. The inserts in one bacteremic patient were infected from a distant bloodstream focus; however, in the majority of patients, quantitative intradermal cultures suggested that the insertion site was the portal of entry. In bacteremic patients, either a positive quantitative or a nonquantitative culture identified an infected insert. However, only 33% of positive nonquantitative insert cultures from nonbacteremic patients were confirmed by quantitative insert culture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antibiotic Susceptibility Testing by a Standardized Single Disk Method
Bauer, A. W., Kirby, W. M. M., Sherris, J. C., & Turck, M. (1966) · American Journal of Clinical Pathology · doi:10.1093/ajcp/45.4_ts.493 · Cited by 18,523
A Semiquantitative Culture Method for Identifying Intravenous-Catheter-Related Infection
Maki, D. G., Weise, C. E., & Sarafin, H. W. (1977) · New England Journal of Medicine · doi:10.1056/nejm197706092962301 · Cited by 2,027
Ryan, J. A., Abel, R. M., Abbott, W. M., Hopkins, C. C., Chesney, T. M., COLLEY, R., Phillips, K., & Fischer, J. E. (1974) · New England Journal of Medicine · doi:10.1056/nejm197404042901401 · Cited by 721
Infection Control in Intravenous Therapy
MAKI, D. G., GOLDMNAN, D. A., & RHAME, F. S. (1973) · Annals of Internal Medicine · doi:10.7326/0003-4819-79-6-867 · Cited by 536
Fibrin Sleeve Formation on Indwelling Subclavian Central Venous Catheters
Hoshal, V. L. (1971) · Archives of Surgery · doi:10.1001/archsurg.1971.01350040115023 · Cited by 368
Subclavian Vein Catheterizations: A Prospective Study
BERNARD, R. W., & STAHL, W. M. (1971) · Annals of Surgery · doi:10.1097/00000658-197102000-00002 · Cited by 343
Etiology of Catheter-Associated Sepsis: Correlation With Thrombogenicity
Stillman, R. M., Soliman, F., Garcia, L., & SAWYER, P. N. (1977) · Archives of Surgery · doi:10.1001/archsurg.1977.01370120087011 · Cited by 163
Use of Quantitative Bacteriologic Techniques to Diagnose Catheter-Related Sepsis
Wing, E. J., Norden, C. W., Shadduck, R. K., & Winkelstein, A. (1979) · Archives of Internal Medicine · doi:10.1001/archinte.1979.03630410086026 · Cited by 137
Zinner, S. H., Denny-Brown, B. C., Braun, P., Burke, J., Toala, P., & Kass, E. H. (1969) · The Journal of Infectious Diseases · doi:10.1093/infdis/120.5.616 · Cited by 131
Gardner, R. M., Schwartz, R. F., Wong, H. C., & Burke, J. P. (1974) · New England Journal of Medicine · doi:10.1056/nejm197405302902205 · Cited by 131
INFUSION THROMBOPHLEBITIS AND INFECTION WITH VARIOUS CANNULAS
Collin, J., Constable, F. L., Collin, C., & Johnston, I. D. A. (1975) · The Lancet · doi:10.1016/s0140-6736(75)90057-4 · Cited by 121
Application of Antibiotic Ointment to the Site of Venous Catheterization--a Controlled Trial
Norden, C. W. (1969) · The Journal of Infectious Diseases · doi:10.1093/infdis/120.5.611 · Cited by 112
Watanakunakorn, C., & Baird, I. M. (1977) · The American Journal of Medicine · doi:10.1016/0002-9343(77)90239-x · Cited by 95
INFECTION FROM INTRAVENOUS CATHETERS
Banks, D. C., Cawdrey, H. M., Yates, D. B., Harries, M. G., & Kidner, P. H. (1970) · The Lancet · doi:10.1016/s0140-6736(70)90833-0 · Cited by 76
Incidence of complications from indwelling venous catheters.
Rb, B. (1969) · PubMed · Cited by 17
Cited by
Mermel, L. A., Allon, M., Bouza, E., Craven, D. E., Flynn, P., O'Grady, N. P., Raad, I. I., Rijnders, B. J. A., Sherertz, R. J., & Warren, D. K. (2009) · Clinical Infectious Diseases · doi:10.1086/599376 · Cited by 3,638
“Staphylococci are the main etiologic agents, followed by Enterococcus and Candida species [24, 25].”
BackgroundGuidelines for the management of intravascular catheter-related infections
Mermel, L. A., Farr, B. M., Sherertz, R. J., Raad, I. I., O'Grady, N., Harris, J. S., & Craven, D. E. (2001) · Clinical Infectious Diseases · doi:10.1086/320001 · Cited by 1,449
Update on clinical significance of coagulase-negative staphylococci
Kloos, W. E., & Bannerman, T. L. (1994) · Clinical Microbiology Reviews · doi:10.1128/cmr.7.1.117 · Cited by 835
American Burn Association Consensus Conference to Define Sepsis and Infection in Burns
Greenhalgh, D. G., Saffle, J. R., Holmes, J. H., Gamelli, R. L., Palmieri, T. L., Horton, J. W., Tompkins, R. G., Traber, D. L., Mozingo, D. W., Deitch, E. A., et al. (2007) · Journal of Burn Care & Research · doi:10.1097/bcr.0b013e3181599bc9 · Cited by 695
Raad, I., Costerton, W., Sabharwal, U., Sadlowski, M., Anaissie, E., & Bodey, G. P. (1993) · Journal of Infectious Diseases · doi:10.1093/infdis/168.2.400 · Cited by 553
Metadata
- Authors
- Cleri, D. J., Corrado, M. L., & Seligman, S. J.
- Venue
- Journal of Infectious Diseases
- Publisher
- Oxford University Press (OUP)
- Published
- 1980-06-01
- Volume
- 141
- Issue
- 6
- Pages
- 781-786
- ISSN
- 0022-1899 (ISSN-L)
- 1537-6613
- OpenAlex
- W2124571466
- Cited by
- 365
- References
- 15
- FWCI
- 12.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.