Ultrastructural Analysis of Indwelling Vascular Catheters: A Quantitative Relationship between Luminal Colonization and Duration of Placement
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
To assess the degree of luminal and extraluminal colonization of long-term central venous catheters (CVC), 359 indwelling silicone CVC from 340 consecutive cancer patients were examined. All CVC were cultured by the roll-plate and sonication quantitative culture techniques. Semiquantitative electron microscopy was done on 39 CVC associated with catheter infections and on 26 culture-negative controls. An additional 10 culture-negative CVC obtained after death were also studied by electron microscopy. Ultrastructural colonization and biofilm formation was universal and quantitatively independent of clinical catheter-related infections. Ultrastructural colonization and biofilm formation was predominantly luminal in long-term CVC (> 30 days). Based on a composite definition, the sensitivity of the roll-plate catheter tip culture was 42%-45% compared with 65%-72% for the sonication of the tip. Colonization of indwelling catheters is universal regardless of culture results. For long-term CVC, colonization becomes predominantly luminal and extraluminal quantitative catheter cultures are of limited diagnostic sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Semiquantitative Culture Method for Identifying Intravenous-Catheter-Related Infection
Maki, D. G., Weise, C. E., & Sarafin, H. W. (1977) · New England Journal of Medicine · doi:10.1056/nejm197706092962301 · Cited by 2,027
Adherence of slime-producing strains of Staphylococcus epidermidis to smooth surfaces
Christensen, G. D., Simpson, W. A., Bisno, A. L., & Beachey, E. H. (1982) · Infection and Immunity · doi:10.1128/iai.37.1.318-326.1982 · Cited by 1,410
Maki, D. G., Alvarado, C. J., & Ringer, M. (1991) · The Lancet · doi:10.1016/0140-6736(91)90479-9 · Cited by 845
Herrmann, M., Vaudaux, P. E., Pittet, D., Auckenthaler, R., Lew, P. D., Perdreau, F. S., Peters, G., & Waldvogel, F. A. (1988) · The Journal of Infectious Diseases · doi:10.1093/infdis/158.4.693 · Cited by 522
Liñares, J., Sitges-Serra, A., Garau, J., Pérez, J. L., & Martín, R. (1985) · Journal of Clinical Microbiology · doi:10.1128/jcm.21.3.357-360.1985 · Cited by 474
Maki, D. G., Cobb, L., Garman, J. K., Shapiro, J. M., Ringer, M., & Helgerson, R. B. (1988) · The American Journal of Medicine · doi:10.1016/0002-9343(88)90579-7 · Cited by 412
Sherertz, R. J., Raad, I. I., Belani, A., Koo, L. C., Rand, K. H., Pickett, D. L., Straub, S. A., & Fauerbach, L. L. (1990) · Journal of Clinical Microbiology · doi:10.1128/jcm.28.1.76-82.1990 · Cited by 381
Self-citationQuantitative Culture of Intravenous Catheters and Other Intravascular Inserts
Cleri, D. J., Corrado, M. L., & Seligman, S. J. (1980) · Journal of Infectious Diseases · doi:10.1093/infdis/141.6.781 · Cited by 365
A scanning and transmission electron microscopic study of an infected endocardial pacemaker lead.
Marrie, T. J., Nelligan, J., & Costerton, J. W. (1982) · Circulation · doi:10.1161/01.cir.66.6.1339 · Cited by 347
BJORNSON, H. S., COLLEY, R., Bower, R. H., Duty, V. P., Schwartz-Fulton, J., & Fischer, J. E. (1982) · PubMed · Cited by 272
Vaudaux, P., Pittet, D., Haeberli, A., Huggler, E., Nydegger, U. E., Lew, D. P., & Waldvogel, F. A. (1989) · Journal of Infectious Diseases · doi:10.1093/infdis/160.5.865 · Cited by 234
Maki, D. G., & Band, J. D. (1981) · The American Journal of Medicine · doi:10.1016/0002-9343(81)90605-7 · Cited by 226
Sitges‐Serra, A., Puig, P., Liñares, J., Pérez, J. L., Farreró, N., Jaurrieta, E., & Garau, J. (1984) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607184008006668 · Cited by 218
Schwartz, C. L., Henrickson, K. J., Roghmann, K. J., & Powell, K. (1990) · Journal of Clinical Oncology · doi:10.1200/jco.1990.8.9.1591 · Cited by 196
Cooper, G. L., & Hopkins, C. C. (1985) · New England Journal of Medicine · doi:10.1056/nejm198505023121802 · Cited by 185
Sitges‐Serra, A., Liñares, J., Pérez, J. L., Jaurrieta, E., & Lorente, L. (1985) · Journal of Parenteral and Enteral Nutrition · doi:10.1177/0148607185009003322 · Cited by 160
Quantitative tip culture methods and the diagnosis of central venous catheter-related infections
Raad, I. I., Sabbagh, M. F., Rand, K. H., & Sherertz, R. J. (1992) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/0732-8893(92)90052-u · Cited by 146
Self-citationTenney, J. H. (1986) · Archives of Internal Medicine · doi:10.1001/archinte.146.10.1949 · Cited by 94
Cited by
Biofilms: Survival Mechanisms of Clinically Relevant Microorganisms
Donlan, R. M., & Costerton, J. W. (2002) · Clinical Microbiology Reviews · doi:10.1128/cmr.15.2.167-193.2002 · Cited by 6,644
“(160) also showed that catheters in place for less than 10 days tended to have more extensive biofilm formation on the external surface of the catheter; for longer-term catheters (up to 30 days), biofilms were more extensive on the internal lumen.”
BackgroundGuidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Self-citationMermel, L. A., Allon, M., Bouza, E., Craven, D. E., Flynn, P., O'Grady, N. P., Raad, I. I., Rijnders, B. J. A., Sherertz, R. J., & Warren, D. K. (2009) · Clinical Infectious Diseases · doi:10.1086/599376 · Cited by 3,638
“In some studies, the rollplate method was less sensitive than other methods that also sampled the internal surface of such catheters [10, 26], but other studies have not found this to be the case [27].”
ResultSelf-citationFreifeld, A. G., Bow, E. J., Sepkowitz, K. A., Boeckh, M. J., Ito, J. I., Mullen, C. A., Raad, I. I., Rolston, K. V., Young, J.-A. H., & Wingard, J. R. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir073 · Cited by 3,463
Self-citationPreventing Complications of Central Venous Catheterization
McGee, D. C., & Gould, M. K. (2003) · New England Journal of Medicine · doi:10.1056/nejmra011883 · Cited by 2,290
Metadata
- Authors
- Raad, I., Costerton, W., Sabharwal, U., Sadlowski, M., Anaissie, E., & Bodey, G. P.
- Venue
- Journal of Infectious Diseases
- Publisher
- Oxford University Press (OUP)
- Published
- 1993-08-01
- Volume
- 168
- Issue
- 2
- Pages
- 400-407
- ISSN
- 0022-1899 (ISSN-L)
- 1537-6613
- OpenAlex
- W2076570067
- Cited by
- 553
- References
- 18
- FWCI
- 19.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.