Underascertainment of Respiratory Syncytial Virus Infection in Adults Due to Diagnostic Testing Limitations: A Systematic Literature Review and Meta-analysis
Open accessThe DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Background: Most observational population-based studies identify respiratory syncytial virus (RSV) by nasal/nasopharyngeal swab reverse transcriptase real-time PCR (RT-PCR) only. We conducted a systematic review and meta-analyses to quantify specimen and diagnostic testing-based underascertainment of adult RSV infection. Methods: EMBASE, PubMed, and Web of Science were searched (January 2000−December 2021) for studies including adults using/comparing >1 RSV testing approach. We quantified test performance and RSV detection increase associated with using multiple specimen types. Results: Among 8066 references identified, 154 met inclusion. Compared to RT-PCR, other methods were less sensitive: rapid antigen detection test (RADT; pooled sensitivity, 64%), direct fluorescent antibody (DFA; 83%), and viral culture (86%). Compared to singleplex PCR, multiplex PCR's sensitivity was lower (93%). Compared to nasal/nasopharyngeal swab RT-PCR alone, adding another specimen type increased detection: sputum RT-PCR, 52%; 4-fold rise in paired serology, 44%; and oropharyngeal swab RT-PCR, 28%. Sensitivity was lower in estimates limited to only adults (for RADT, DFA, and viral culture), and detection rate increases were largely comparable. Conclusions: RT-PCR, particularly singleplex testing, is the most sensitive RSV diagnostic test in adults. Adding additional specimen types to nasopharyngeal swab RT-PCR testing increased RSV detection. Synergistic effects of using ≥3 specimen types should be assessed, as this approach may improve the accuracy of adult RSV burden estimates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199 · cited 1×
“Study quality assessment was performed by one reviewer and verified by a second reviewer using Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) criteria [11].”
Troeger, C., Blacker, B., Khalil, I. A., Rao, P. C., Cao, J., Zimsen, S. R. M., Albertson, S. B., Deshpande, A., Farag, T., Abebe, Z., et al. (2018) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(18)30310-4 · Cited by 1,968
Self-citationSalameh, J.-P., Bossuyt, P. M., McGrath, T. A., Thombs, B. D., Hyde, C. J., Macaskill, P., Deeks, J. J., Leeflang, M., Korevaar, D. A., Whiting, P., et al. (2020) · BMJ · doi:10.1136/bmj.m2632 · Cited by 719
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W., Westwood, M. E., Mallett, S. V., Deeks, J. J., Reitsma, J. B., Leeflang, M., Sterne, J. A. C., & Bossuyt, P. M. (2011) · Data Archiving and Networked Services (DANS) · doi:10.1059/0003-4819-155-8-201110180-00009 · Cited by 601
Shi, T., Denouel, A., Tietjen, A. K., Campbell, I., Moran, E., Li, X., Campbell, H., Demont, C., Nyawanda, B. O., Chu, H. Y., et al. (2020) · The Journal of Infectious Diseases · doi:10.1093/infdis/jiz059 · Cited by 526 · cited 1×
“Adults are known to have lower viral loads in their respiratory secretions than children [2], likely explaining these lower results.”
ResultSelf-citationKuypers, J., Wright, N., Ferrenberg, J., Huang, M.-L., Cent, A., Corey, L., & Morrow, R. (2006) · Journal of Clinical Microbiology · doi:10.1128/jcm.00216-06 · Cited by 323
Chartrand, C., Tremblay, N., Renaud, C., & Papenburg, J. (2015) · Journal of Clinical Microbiology · doi:10.1128/jcm.01816-15 · Cited by 262 · cited 3×
“Reverse transcriptase real-time polymerase chain reaction (RT-PCR) has become the reference diagnostic method for RSV detection due to its high diagnostic accuracy [3, 5].”
BackgroundMethodTo, K. K., Yip, C. C., Lai, C. Y. W., Wong, C. K. H., Ho, D. T. Y., Pang, P. K. P., Ng, A. C. K., Leung, K., Poon, R. W., Chan, K.-H., et al. (2018) · Clinical Microbiology and Infection · doi:10.1016/j.cmi.2018.06.009 · Cited by 226
Rates of Medically Attended RSV Among US Adults: A Systematic Review and Meta-analysis
McLaughlin, J. M., Khan, F., Begier, E., Swerdlow, D. L., Jodar, L., & Falsey, A. R. (2022) · Open Forum Infectious Diseases · doi:10.1093/ofid/ofac300 · Cited by 224 · cited 2×
“A rise in serology titers (≥4-fold rise between acute/convalescence or pre-/postseason specimens) can identify recent RSV infection although some adults do not seroconvert [6, 7].”
BackgroundSelf-citationFalsey, A. R., Formica, M. A., & Walsh, E. E. (2002) · Journal of Clinical Microbiology · doi:10.1128/jcm.40.3.817-820.2002 · Cited by 194 · cited 16×
“However, not all with confirmed RSV-infection by PCR or viral culture seroconvert and false-negative serology can also occur due to already elevated IgG level in the acute specimen [46], especially if collected at hospital admission after several days of illness [7, 46].”
BackgroundInfluential
Cited by
Melgar, M., Britton, A., Roper, L. E., Talbot, H. K., Long, S. S., Kotton, C. N., & Havers, F. P. (2023) · MMWR. Morbidity and Mortality Weekly Report · doi:10.15585/mmwr.mm7229a4 · Cited by 328
Metadata
- Authors
- Onwuchekwa, C., Moreo, L. M., Menon, S., Machado, B., Curcio, D., Kalina, W., Atwell, J. E., Gessner, B. D., Siapka, M., Agarwal, N., Rubbrecht, M., Nair, H., Rozenbaum, M., Aponte-Torres, Z., Vroling, H., & Begier, E.
- Venue
- The Journal of Infectious Diseases
- Publisher
- Oxford University Press (OUP)
- Published
- 2023-01-20
- Volume
- 228
- Issue
- 2
- Pages
- 173-184
- ISSN
- 0022-1899 (ISSN-L)
- 1537-6613
- OpenAlex
- W4317567014
- Cited by
- 205
- References
- 31
- FWCI
- 11.04
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.