Associations between healthcare quality and use of electronic health record functions in ambulatory care
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
Objectives Contemporary electronic health records (EHRs) offer a wide variety of features, creating opportunities to influence healthcare quality in different ways. This study was designed to assess the relationship between physician use of individual EHR functions and healthcare quality. Materials and Methods Sixty-five providers eligible for “meaningful use” were included. Data were abstracted from office visit records during the study timeframe (183 095 visits with 61 977 patients). Three EHR functions were considered potential predictors: acceptance of best practice alerts, use of order sets, and viewing panel-level reports. Eighteen clinical quality measures from the “meaningful use” program were abstracted. Results Use of condition-specific best-practice alerts and order sets was associated with better scores on clinical quality measures capturing processes in diabetes, cancer screening, tobacco cessation, and pneumonia vaccination. For example, providers above the median in use of tobacco-related alerts had higher performance on tobacco cessation intervention metrics (median 80.6% vs. 66.7%; P < .001), and providers above the median in use of diabetes order sets had higher quality on diabetes low density lipoprotein (LDL) testing (68.2% vs. 59.5%; P == .001). Post hoc examination of the results showed that the positive associations were with measures of healthcare processes (such as rates of LDL testing), whereas there were no positive associations with measures of healthcare outcomes (such as LDL levels). Discussion Among primary care providers in the ambulatory setting using a single EHR, intensive use of certain EHR functions was associated with increased adherence to recommended care as measured by performance on electronically reported “meaningful use” quality measures. This study is relevant to current policy as it uses quality metrics constructed by contemporary certified EHR technology, and quantitative EHR use metrics rather than self-reported use. Conclusion In the early stages of the “meaningful use” program, use of specific EHR functions was associated with higher performance on healthcare process metrics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlling the False Discovery Rate: A Practical and Powerful Approach to Multiple Testing
Benjamini, Y., & Hochberg, Y. (1995) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1995.tb02031.x · Cited by 109,482
Chaudhry, B., Wang, J., Wu, S., Maglione, M., Mojica, W., Roth, E., Morton, S. C., & Shekelle, P. G. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-144-10-200605160-00125 · Cited by 3,159
The “Meaningful Use” Regulation for Electronic Health Records
Blumenthal, D., & Tavenner, M. (2010) · New England Journal of Medicine · doi:10.1056/nejmp1006114 · Cited by 2,059
Bias and causal associations in observational research
Grimes, D. A., & Schulz, K. F. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07451-2 · Cited by 1,553
Delgado-Rodríguez, M., & Llorca, J. (2004) · Journal of Epidemiology and Community Health · doi:10.1136/jech.2003.008466 · Cited by 1,064
Development and Application of a Population-Oriented Measure of Ambulatory Care Case-Mix
Weiner, J. P., Starfield, B. H., Steinwachs, D. M., & Mumford, L. M. (1991) · Medical Care · doi:10.1097/00005650-199105000-00006 · Cited by 677
A Computerized Reminder System to Increase the Use of Preventive Care for Hospitalized Patients
Dexter, P. R., Perkins, S., Overhage, J. M., Maharry, K., Kohler, R. B., & McDonald, C. J. (2001) · New England Journal of Medicine · doi:10.1056/nejmsa010181 · Cited by 519
Ammenwerth, E., Iller, C., & Mahler, C. (2006) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-6-3 · Cited by 459
Information Overload and Missed Test Results in Electronic Health Record–Based Settings
Singh, H., Spitzmueller, C., Petersen, N. J., Sawhney, M. K., & Sittig, D. F. (2013) · JAMA Internal Medicine · doi:10.1001/2013.jamainternmed.61 · Cited by 209
Validity of electronic health record-derived quality measurement for performance monitoring
Parsons, A., McCullough, C., Wang, J., & Shih, S. (2012) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2011-000557 · Cited by 137
Cited by
Electronic Health Records: Then, Now, and in the Future
Evans, R. S. (2016) · Yearbook of Medical Informatics · doi:10.15265/iys-2016-s006 · Cited by 768
with the HITEC Investigators, Ancker, J. S., Edwards, A., Nosal, S., Hauser, D., Mauer, E., & Kaushal, R. (2017) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-017-0430-8 · Cited by 709
“Additional details from this study are published elsewhere [29, 30].”
BackgroundSelf-citationDunn Lopez, K., Chin, C.-L., Leitão Azevedo, R. F., Kaushik, V., Roy, B., Schuh, W., Banks, K., Sousa, V., & Morrow, D. (2021) · Applied Ergonomics · doi:10.1016/j.apergo.2021.103359 · Cited by 62
Chen, H., Butler, E., Guo, Y., George, T., Modave, F., Gurka, M., & Bian, J. (2019) · Health Communication · doi:10.1080/10410236.2018.1443263 · Cited by 24
“The researchers ’ study found that medical practitioners who adopted BPAs at a level above the average rate showed greater success for four preventative aid procedures (Ancker et al., 2015).”
BackgroundMethod
Metadata
- Authors
- Ancker, J. S., Kern, L. M., Edwards, A., Nosal, S., Stein, D. M., Hauser, D., Kaushal, R., & with the HITEC Investigators
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2015-04-20
- Volume
- 22
- Issue
- 4
- Pages
- 864-871
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- OpenAlex
- W1937693759
- Cited by
- 65
- References
- 12
- FWCI
- 12.64
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.