Accuracy of Screening Mammography Interpretation by Characteristics of Radiologists
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Radiologists differ in their ability to interpret screening mammograms accurately. We investigated the relationship of radiologist characteristics to actual performance from 1996 to 2001. METHODS: Screening mammograms (n = 469,512) interpreted by 124 radiologists were linked to cancer outcome data. The radiologists completed a survey that included questions on demographics, malpractice concerns, years of experience interpreting mammograms, and the number of mammograms read annually. We used receiver operating characteristics (ROC) analysis to analyze variables associated with sensitivity, specificity, and the combination of the two, adjusting for patient variables that affect performance. All P values are two-sided. RESULTS: Within 1 year of the mammogram, 2402 breast cancers were identified. Relative to low annual interpretive volume (< or =1000 mammograms), greater interpretive volume was associated with higher sensitivity (P = .001; odds ratio [OR] for moderate volume [1001-2000] = 1.68, 95% CI = 1.18 to 2.39; OR for high volume [>2000] = 1.89, 95% CI = 1.36 to 2.63). Specificity decreased with volume (OR for 1001-2000 = 0.65, 95% CI = 0.52 to 0.83; OR for more than 2000 = 0.76, 95% CI = 0.60 to 0.96), compared with 1000 or less (P = .002). Greater number of years of experience interpreting mammograms was associated with lower sensitivity (P = .001), but higher specificity (P = .003). ROC analysis using the ordinal BI-RADS interpretation showed an association between accuracy and both previous mammographic history (P = .012) and breast density (P<.001). No association was observed between accuracy and years interpreting mammograms (P = .34) or mammography volume (P = .94), after adjusting for variables that affect the threshold for calling a mammogram positive. CONCLUSIONS: We found no evidence that greater volume or experience at interpreting mammograms is associated with better performance. However, they may affect sensitivity and specificity, possibly by determining the threshold for calling a mammogram positive. Increasing volume requirements is unlikely to improve overall mammography performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Longitudinal Data Analysis for Discrete and Continuous Outcomes
Zeger, S. L., & Liang, K.-Y. (1986) · Biometrics · doi:10.2307/2531248 · Cited by 7,764 · cited 1×
“A generalized estimating equations (GEE) approach is based on a marginal model assuming a working correlation structure to adjust the standard errors for the correlation ( 24 ) and provides valid inference without requiring that the correlation structure be correctly specified.”
MethodDialysis Dose and Intradialytic Hypotension: Results from the HEMO Study
Mc Causland, F. R., Brunelli, S. M., & Waikar, S. S. (2013) · American Journal of Nephrology · doi:10.1159/000355958 · Cited by 2,690
Carney, P. A., Miglioretti, D. L., Yankaskas, B. C., Kerlikowske, K., Rosenberg, R., Rutter, C. M., Geller, B. M., Abraham, L. A., Taplin, S. H., Dignan, M., et al. (2003) · Annals of Internal Medicine · doi:10.7326/0003-4819-138-3-200302040-00008 · Cited by 1,142
Self-citationBreast Cancer Screening: A Summary of the Evidence for the U.S. Preventive Services Task Force
Humphrey, L. L., Helfand, M., Chan, B. K. S., & Woolf, S. H. (2002) · Annals of Internal Medicine · doi:10.7326/0003-4819-137-5_part_1-200209030-00012 · Cited by 1,137
Dorfman, D. D., & Alf, E. (1969) · Journal of Mathematical Psychology · doi:10.1016/0022-2496(69)90019-4 · Cited by 874 · cited 2×
“Without covariates, the model reduces to the usual binormal model ( 27 ,29).”
MethodSome Practical Issues of Experimental Design and Data Analysis in Radiological ROC Studies
METZ, C. E. (1989) · Investigative Radiology · doi:10.1097/00004424-198903000-00012 · Cited by 859 · cited 1×
“Without covariates, the model reduces to the usual binormal model (27, 29 ).”
MethodVariability in Radiologists' Interpretations of Mammograms
Elmore, J. G., Wells, C. K., Lee, C. H., Howard, D. H., & Feinstein, A. R. (1994) · New England Journal of Medicine · doi:10.1056/nejm199412013312206 · Cited by 601 · cited 1×
“The accuracy of mammographic interpretation among individual radiologists varies widely ( 4 ,5).”
BackgroundSelf-citationRosenberg, R. D., Hunt, W. C., Williamson, M. R., Gilliland, F. D., Wiest, P. W., Kelsey, C. A., Key, C. R., & Linver, M. N. (1998) · Radiology · doi:10.1148/radiology.209.2.9807581 · Cited by 364
Beam, C. A. (1996) · Archives of Internal Medicine · doi:10.1001/archinte.1996.00440020119016 · Cited by 337
Missed Breast Carcinoma: Pitfalls and Pearls
Majid, A. S., de Paredes, E. S., Doherty, R. D., Sharma, N. R., & Salvador, X. (2003) · RadioGraphics · doi:10.1148/rg.234025083 · Cited by 275
Cited by
Rodriguez-Ruiz, A., Lång, K., Gubern-Merida, A., Broeders, M., Gennaro, G., Clauser, P., Helbich, T. H., Chevalier, M., Tan, T., Mertelmeier, T., et al. (2019) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djy222 · Cited by 692
Influence of Computer-Aided Detection on Performance of Screening Mammography
Fenton, J. J., Taplin, S. H., Carney, P. A., Abraham, L., Sickles, E. A., D'Orsi, C., Berns, E. A., Cutter, G., Hendrick, R. E., Barlow, W. E., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa066099 · Cited by 619
Self-citationHubbard, R. A., Kerlikowske, K., Flowers, C. I., Yankaskas, B. C., Zhu, W., & Miglioretti, D. L. (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00004 · Cited by 414
Content-based image retrieval in radiology: current status and future directions
Akgül, C. B., Rubin, D. L., Napel, S., Beaulieu, C. F., Greenspan, H., & Acar, B. (2011) · Journal of Digital Imaging · doi:10.1007/s10278-010-9290-9 · Cited by 388
Performance Benchmarks for Screening Mammography
Rosenberg, R. D., Yankaskas, B. C., Abraham, L. A., Sickles, E. A., Lehman, C. D., Geller, B. M., Carney, P. A., Kerlikowske, K., Buist, D. S. M., Weaver, D. L., et al. (2006) · Radiology · doi:10.1148/radiol.2411051504 · Cited by 336
Self-citationDiscrimination of Breast Cancer with Microcalcifications on Mammography by Deep Learning
Wang, J., Yang, X., Cai, H., Tan, W., Jin, C., & Li, L. (2016) · Scientific Reports · doi:10.1038/srep27327 · Cited by 291
Salim, M., Wåhlin, E., Dembrower, K., Azavedo, E., Foukakis, T., Liu, Y., Smith, K., Eklund, M., & Strand, F. (2020) · JAMA Oncology · doi:10.1001/jamaoncol.2020.3321 · Cited by 288
Barclay, R. L., Vicari, J. J., & Greenlaw, R. L. (2008) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2008.04.018 · Cited by 271
Elmore, J. G., Jackson, S. L., Abraham, L., Miglioretti, D. L., Carney, P. A., Geller, B. M., Yankaskas, B. C., Kerlikowske, K., Onega, T., Rosenberg, R. D., et al. (2009) · Radiology · doi:10.1148/radiol.2533082308 · Cited by 263
Self-citationCADx of mammographic masses and clustered microcalcifications: A review
Elter, M., & Horsch, A. (2009) · Medical Physics · doi:10.1118/1.3121511 · Cited by 204
Sorin, V., Yagil, Y., Yosepovich, A., Shalmon, A., Gotlieb, M., Neiman, O. H., & Sklair-Levy, M. (2018) · American Journal of Roentgenology · doi:10.2214/ajr.17.19355 · Cited by 181
“[25] to obtain an ordinal scale: 1, 2, 3, 0, 4, and 5.”
Current status and future directions of computer-aided diagnosis in mammography
Nishikawa, R. M. (2007) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2007.02.009 · Cited by 175
Errors in cancer diagnosis: current understanding and future directions
Singh, H., Sethi, S., Raber, M., & Petersen, L. A. (2007) · Journal of Clinical Oncology · doi:10.1200/jco.2007.13.2142 · Cited by 121
Dvijotham, K., Winkens, J., Barsbey, M., Ghaisas, S., Stanforth, R., Pawlowski, N., Strachan, P., Ahmed, Z., Azizi, S., Bachrach, Y., et al. (2023) · Nature Medicine · doi:10.1038/s41591-023-02437-x · Cited by 120
Artificial Intelligence in Imaging: The Radiologist’s Role
Rubin, D. L. (2019) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2019.05.036 · Cited by 110
Choi, J. S., Han, B.-K., Ko, E. S., Bae, J. M., Ko, E. Y., Song, S. H., Kwon, M.-R., Shin, J. H., & Hahn, S. Y. (2019) · Korean Journal of Radiology · doi:10.3348/kjr.2018.0530 · Cited by 104
Evaluating Imaging and Computer-aided Detection and Diagnosis Devices at the FDA
Gallas, B. D., Chan, H.-P., D’Orsi, C. J., Dodd, L. E., Giger, M. L., Gur, D., Krupinski, E. A., Metz, C. E., Myers, K. J., Obuchowski, N. A., et al. (2012) · Academic Radiology · doi:10.1016/j.acra.2011.12.016 · Cited by 81
Self-citation
Metadata
- Authors
- Barlow, W. E., Chi, C., Carney, P. A., Taplin, S. H., D'Orsi, C., Cutter, G., Hendrick, R. E., & Elmore, J. G.
- Venue
- JNCI Journal of the National Cancer Institute
- Publisher
- Oxford University Press (OUP)
- Published
- 2004-12-14
- Volume
- 96
- Issue
- 24
- Pages
- 1840-1850
- ISSN
- 0027-8874 (ISSN-L)
- 1460-2105
- OpenAlex
- W2028177593
- Cited by
- 216
- References
- 27
- FWCI
- 7.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.