The DOI matches its Crossref record.
Self-assembly of DNA-streptavidin nanostructures and their use as reagents in immuno-PCR
Open accessAbstract
The self-assembly of bis-biotinylated double-stranded DNA and the tetravalent biotin-binding protein streptavidin (STV) have been studied by non-denaturing gel electrophoresis and atomic force microscopy (AFM). The rapid self-assembly reproducibly generated populations of individual oligomeric complexes. Most strikingly, the oligomers predominantly contained bivalent STV molecules bridging two adjacent DNA fragments to form linear nanostructures. Trivalent STV branch points occurred with a lower frequency and the presence of tetravalent STV was scarce. However, valency distribution, size and the exchange dynamics of the supramolecular aggregates were highly sensitive to stoichiometric variations in the relative molar coupling ratio of bis-biotinylated DNA and STV. The largest aggregates were obtained from equimolar amounts while excess STV led to the formation of smaller oligomers appearing as fingerprint-like band patterns in electrophoresis. Excess DNA, however, induces a complete breakdown of the oligomers, likely a consequence of the instability of STV conjugates containing more than two biotinylated DNA fragments. It was demonstrated that the oligomers can further be functionalized, for instance by the coupling of biotinylated immunoglobulins. Both pure and also antibody-modified DNA-STV oligomers were used as reagents in immuno-PCR (IPCR), a highly sensitive detection method for proteins and other antigens. Employment of the supramolecular reagents led to an approximately 100-fold enhanced sensitivity compared to the conventional IPCR procedure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Nanoparticle-Based Bio-Bar Codes for the Ultrasensitive Detection of Proteins
Nam, J.-M., Thaxton, C. S., & Mirkin, C. A. (2003) · Science · doi:10.1126/science.1088755 · Cited by 2,390
Applications of Aptamers as Sensors
Cho, E. J., Lee, J.-W., & Ellington, A. D. (2009) · Annual Review of Analytical Chemistry · doi:10.1146/annurev.anchem.1.031207.112851 · Cited by 788
Pharmaceuticals: a threat to drinking water?
Jones, O. A., Lester, J. N., & Voulvoulis, N. (2005) · Trends in Biotechnology · doi:10.1016/j.tibtech.2005.02.001 · Cited by 531
Cytokine detection by antibody-based proximity ligation
Gullberg, M., Gústafsdóttir, S. M., Schallmeiner, E., Jarvius, J., Bjarnegård, M., Betsholtz, C., Landegren, U., & Fredriksson, S. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0400552101 · Cited by 411
Semisynthetic DNA–Protein Conjugates for Biosensing and Nanofabrication
Niemeyer, C. M. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200904930 · Cited by 369
Self-citation
Metadata
- Authors
- Niemeyer, C.
- Venue
- Nucleic Acids Research
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-12-01
- Volume
- 27
- Issue
- 23
- Pages
- 4553-4561
- ISSN
- 0305-1048 (ISSN-L)
- 1362-4962
- OpenAlex
- W2079066025
- Cited by
- 211
- References
- 0
- FWCI
- 3.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Self-assembly of DNA-streptavidin nanostructures and their use as reagents in immuno-PCR. https://app.cochat.ai/papers/10.1093/nar/27.23.4553
- The paper
- Niemeyer, C. (1999). Self-assembly of DNA-streptavidin nanostructures and their use as reagents in immuno-PCR. Nucleic Acids Research. https://doi.org/10.1093/nar/27.23.4553
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.