By-passing in vitro screening—next generation sequencing technologies applied to antibody display and in silico candidate selection
Open accessThe DOI matches its Crossref record; 39 of the 39 references it cites were found in a registry or an index.
Abstract
In recent years, unprecedented DNA sequencing capacity provided by next generation sequencing (NGS) has revolutionized genomic research. Combining the Illumina sequencing platform and a scFv library designed to confine diversity to both CDR3, >1.9 × 10(7) sequences have been generated. This approach allowed for in depth analysis of the library's diversity, provided sequence information on virtually all scFv during selection for binding to two targets and a global view of these enrichment processes. Using the most frequent heavy chain CDR3 sequences, primers were designed to rescue scFv from the third selection round. Identification, based on sequence frequency, retrieved the most potent scFv and valuable candidates that were missed using classical in vitro screening. Thus, by combining NGS with display technologies, laborious and time consuming upfront screening can be by-passed or complemented and valuable insights into the selection process can be obtained to improve library design and understanding of antibody repertoires.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sequencing technologies – the next generation
Metzker, M. L. (2010) · Nature Reviews Genetics · doi:10.1038/nrg2626 · Cited by 7,066
Hoogenboom, H. R., Griffiths, A. D., Johnson, K. S., Chiswell, D. J., Hudson, P., & Winter, G. (1991) · Nucleic Acids Research · doi:10.1093/nar/19.15.4133 · Cited by 1,020 · cited 3×
“The pNDS1 vector that was derived from pHEN1 phagemid vector (21).”
MethodSelecting and screening recombinant antibody libraries
Hoogenboom, H. R. (2005) · Nature Biotechnology · doi:10.1038/nbt1126 · Cited by 973
Isolation of high affinity human antibodies directly from large synthetic repertoires.
Griffiths, A. D., Williams, S. C., Hartley, O., Tomlinson, I. M., Waterhouse, P., Crosby, W. L., Kontermann, R. E., Jones, P. T., Low, N. M., & Allison, T. J. (1994) · The EMBO Journal · doi:10.1002/j.1460-2075.1994.tb06626.x · Cited by 962 · cited 1×
“This result was not unexpected as VH3 genes encoded antibody fragments have been shown to be well tolerated in display settings and are often used for the generation of semi-synthetic libraries (23,24,27).”
BackgroundIMGT, the international ImMunoGeneTics database
Ruiz, M. (2000) · Nucleic Acids Research · doi:10.1093/nar/28.1.219 · Cited by 858
[15] Libraries of peptides and proteins displayed on filamentous phage
Smith, G. P., & Scott, J. K. (1993) · Methods in Enzymology · doi:10.1016/0076-6879(93)17065-d · Cited by 769
Monoclonal antibody successes in the clinic
Reichert, J. M., Rosensweig, C. J., Faden, L. B., & Dewitz, M. C. (2005) · Nature Biotechnology · doi:10.1038/nbt0905-1073 · Cited by 733 · cited 1×
“4) 9870 (2) 37 017 (6) Identified VH family 4 680 882 (92) 332 201 (94) 538 706 (96) 619 707 (96) In frame inserts 4 237 321 (91) 322 273 (97) 527 932 (98) 612 130 (99) VL(CDR3-FR4) Total number of sequences 4 412 636 1 531 261 1 302 154 1 649 977 Unique sequences 3 612 120 (82) 733 282 (48) 493 490 (21) 576 062 (19)…”
Engineering novel binding proteins from nonimmunoglobulin domains
Binz, H. K., Amstutz, P., & Plückthun, A. (2005) · Nature Biotechnology · doi:10.1038/nbt1127 · Cited by 676
Antibody arrays for high-throughput screening of antibody–antigen interactions
de Wildt, R. M. T., Mundy, C. R., Gorick, B. D., & Tomlinson, I. M. (2000) · Nature Biotechnology · doi:10.1038/79494 · Cited by 624 · cited 1×
“For instance, it has been shown that selection rounds can be drastically reduced—and potentially even skipped—using high-throughput antibody array screening (32).”
BackgroundAntibody-antigen interactions: new structures and new conformational changes
Wilson, I. A., & Stanfield, R. L. (1994) · Current Opinion in Structural Biology · doi:10.1016/0959-440x(94)90267-4 · Cited by 515 · cited 1×
“However it remains to be fully elucidated whether there is a preferential usage by the immune system of certain variable gene families, CDR lengths and canonical structures for defined target classes (haptens, carbohydrates, peptides or proteins) (24,36,37).”
Background
Cited by
The promise and challenge of high-throughput sequencing of the antibody repertoire
Georgiou, G., Ippolito, G. C., Beausang, J., Busse, C. E., Wardemann, H., & Quake, S. R. (2014) · Nature Biotechnology · doi:10.1038/nbt.2782 · Cited by 652
Nanobodies and Their Potential Applications
Hassanzadeh-Ghassabeh, G., Devoogdt, N., De Pauw, P., Vincke, C., & Muyldermans, S. (2013) · Nanomedicine · doi:10.2217/nnm.13.86 · Cited by 328
Aptamer Selection Technology and Recent Advances
Blind, M., & Blank, M. (2015) · Molecular Therapy - Nucleic Acids · doi:10.1038/mtna.2014.74 · Cited by 322
The state-of-play and future of antibody therapeutics
Elgundi, Z., Reslan, M., Cruz, E., Sifniotis, V., & Kayser, V. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.11.004 · Cited by 322
Alam, K. K., Chang, J. L., & Burke, D. H. (2015) · Molecular Therapy - Nucleic Acids · doi:10.1038/mtna.2015.4 · Cited by 260
Deep mutational scanning: assessing protein function on a massive scale
Araya, C. L., & Fowler, D. M. (2011) · Trends in Biotechnology · doi:10.1016/j.tibtech.2011.04.003 · Cited by 217
“Ravn and colleagues used HTS to facilitate the identification of highaffinity antibody sequences in a phage display library of >107 antibody fragments (scFv), mutagenized in an important loop region (CDR3) [30].”
MethodMiho, E., Yermanos, A., Weber, C. R., Berger, C. T., Reddy, S. T., & Greiff, V. (2018) · Frontiers in Immunology · doi:10.3389/fimmu.2018.00224 · Cited by 189
Phage display screening without repetitious selection rounds
’t Hoen, P. A. C., Jirka, S. M. G., ten Broeke, B. R., Schultes, E. A., Aguilera, B., Pang, K. H., Heemskerk, H., Aartsma-Rus, A., van Ommen, G. J., & den Dunnen, J. T. (2012) · Analytical Biochemistry · doi:10.1016/j.ab.2011.11.005 · Cited by 174
“Thus, NGS permits a more expedient and higher resolution characterization of the library [11–13].”
MethodHu, D., Hu, S., Wan, W., Xu, M., Du, R., Zhao, W., Gao, X., Liu, J., Liu, H., & Hong, J. (2015) · PLOS ONE · doi:10.1371/journal.pone.0129125 · Cited by 86
“In particular, the Illumina platform that can generate millions of high-quality reads per run, and it has excellent capacity for assisting the identification of antibody candidates [19,21,22].”
Background
Metadata
- Authors
- Ravn, U., Gueneau, F., Baerlocher, L., Osteras, M., Desmurs, M., Malinge, P., Magistrelli, G., Farinelli, L., Kosco-Vilbois, M. H., & Fischer, N.
- Venue
- Nucleic Acids Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-09-15
- Volume
- 38
- Issue
- 21
- Pages
- e193-e193
- ISSN
- 0305-1048 (ISSN-L)
- 1362-4962
- OpenAlex
- W2116006352
- Cited by
- 173
- References
- 39
- FWCI
- 10.37
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.