Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Double indexing overcomes inaccuracies in multiplex sequencing on the Illumina platform

Open access
Kircher, Martin, Sawyer, Susanna, Meyer, Matthias · 2012 · Nucleic Acids Research

Abstract

Due to the increasing throughput of current DNA sequencing instruments, sample multiplexing is necessary for making economical use of available sequencing capacities. A widely used multiplexing strategy for the Illumina Genome Analyzer utilizes sample-specific indexes, which are embedded in one of the library adapters. However, this and similar multiplex approaches come with a risk of sample misidentification. By introducing indexes into both library adapters (double indexing), we have developed a method that reveals the rate of sample misidentification within current multiplex sequencing experiments. With ~0.3% these rates are orders of magnitude higher than expected and may severely confound applications in cancer genomics and other fields requiring accurate detection of rare variants. We identified the occurrence of mixed clusters on the flow as the predominant source of error. The accuracy of sample identification is further impaired if indexed oligonucleotides are cross-contaminated or if indexed libraries are amplified in bulk. Double-indexing eliminates these problems and increases both the scope and accuracy of multiplex sequencing on the Illumina platform.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/nar/gkr771

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Figures

Figure 1. (A) Regular Illumina multiplex library design. The grafting sequences (P5 and P7) are used for template immobilization and amplification. Three distinct sequence reads (forward read, index read, reverse read) are primed from different adapter sites. (B) Double-index library design with an additional index incorporated into the second adapter. Here, four distinct sequence reads are performed.
Figure 1. (A) Regular Illumina multiplex library design. The grafting sequences (P5 and P7) are used for template immobilization and amplification. Three distinct sequence reads (forward read, index read, reverse read) are primed from different adapter sites. (B) Double-index library design with an additional index incorporated into the second adapter. Here, four distinct sequence reads are performed.CC BY-NC · PubMed Central
Figure 2. Changes in the fraction of false (blue) and correct (red) index pairs when applying two different types of base quality filters on the index reads (minimum accepted quality score and average quality score). The fraction remaining after PF is indicated by a green ‘sun’ symbol. Black circles denote the fraction of reads remaining when considering quality score cutoffs that remove just a little bit less raw data than the Pass Filter flag (green lines, ~20% of the data). Both filter criteria remove considerably more false pairs. While no-CAP, SP-CAP and MP-CAP show similar trajectories, the fraction of false pairs is always considerably higher for the MP-CAP experiment, in which samples have been enriched and amplified in a multiplex setup. Quality score cutoffs for the SP-CAP experiment are lower than for the other two experiments due to the 40% higher cluster density of this experiment.
Figure 2. Changes in the fraction of false (blue) and correct (red) index pairs when applying two different types of base quality filters on the index reads (minimum accepted quality score and average quality score). The fraction remaining after PF is indicated by a green ‘sun’ symbol. Black circles denote the fraction of reads remaining when considering quality score cutoffs that remove just a little bit less raw data than the Pass Filter flag (green lines, ~20% of the data). Both filter criteria remove considerably more false pairs. While no-CAP, SP-CAP and MP-CAP show similar trajectories, the fraction of false pairs is always considerably higher for the MP-CAP experiment, in which samples have been enriched and amplified in a multiplex setup. Quality score cutoffs for the SP-CAP experiment are lower than for the other two experiments due to the 40% higher cluster density of this experiment.CC BY-NC · PubMed Central
Figure 3. Heat map with the counts observed for all index combinations in the experiments no-CAP, SP-CAP and MP-CAP after applying a minimum quality score filter of 15 to the index reads. Only indexes that were actually used in the experiments are plotted; forward indexes on the horizontal and reverse indexes on the vertical axis. Color frequencies are provided for each of the experiments in the top right graphs.
Figure 3. Heat map with the counts observed for all index combinations in the experiments no-CAP, SP-CAP and MP-CAP after applying a minimum quality score filter of 15 to the index reads. Only indexes that were actually used in the experiments are plotted; forward indexes on the horizontal and reverse indexes on the vertical axis. Color frequencies are provided for each of the experiments in the top right graphs.CC BY-NC · PubMed Central

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

See all 1,106

Metadata

Authors
Kircher, M., Sawyer, S., & Meyer, M.
Affiliations
  • Max Planck Institute for Evolutionary Anthropology (DE)
  • Max Planck Society (DE)
Corresponding author
  • Kircher, Martin
  • Meyer, Matthias
Venue
Nucleic Acids Research
Published
2011-10-21
Volume
40
Issue
1
Pages
e3-e3
ISSN
  • 0305-1048 (ISSN-L)
  • 1362-4962
OpenAlex
W2141599418
Cited by
1,106
References
31
Citations by year
2026: 62 · 2025: 84 · 2024: 55 · 2023: 81 · 2022: 85 · 2021: 115 · 2020: 100 · 2019: 102 · 2018: 113 · 2017: 74 · 2016: 93 · 2015: 57 · 2014: 45 · 2013: 24 · 2012: 14
FWCI
10.90
Type
journal article
Language
en
Open access
Locations
  • Nucleic Acids Research (publishedVersion, cc-by-nc)
  • Europe PMC (PubMed Central) (publishedVersion, cc-by-nc)
  • PubMed Central (publishedVersion, cc-by-nc)
  • PubMed (publishedVersion)
  • MPG.PuRe (Max Planck Society) (submittedVersion, other-oa)
Funders
Max-Planck-Gesellschaft
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Genomics and Phylogenetic Studies
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Genetics › Genomics and Rare Diseases
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Single-cell and spatial transcriptomics
Keywords
sample multiplexing, sample misidentification, mixed clusters, sequencing errors, rare variant detection, cancer genomics, cross-contamination
MeSH terms
Reproducibility of Results, Gene Library, Sequence Analysis, DNA, High-Throughput Nucleotide Sequencing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Double indexing overcomes inaccuracies in multiplex sequencing on the Illumina platform. https://app.cochat.ai/papers/10.1093/nar/gkr771
The paper
Kircher, M., Sawyer, S., & Meyer, M. (2012). Double indexing overcomes inaccuracies in multiplex sequencing on the Illumina platform. Nucleic Acids Research. https://doi.org/10.1093/nar/gkr771

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.