The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Experimental validation of novel and conventional approaches to quantitative real-time PCR data analysis
Open accessAbstract
Real-time PCR is being used increasingly as the method of choice for mRNA quantification, allowing rapid analysis of gene expression from low quantities of starting template. Despite a wide range of approaches, the same principles underlie all data analysis, with standard approaches broadly classified as either absolute or relative. In this study we use a variety of absolute and relative approaches of data analysis to investigate nocturnal c-fos expression in wild-type and retinally degenerate mice. In addition, we apply a simple algorithm to calculate the amplification efficiency of every sample from its amplification profile. We confirm that nocturnal c-fos expression in the rodent eye originates from the photoreceptor layer, with around a 5-fold reduction in nocturnal c-fos expression in mice lacking rods and cones. Furthermore, we illustrate that differences in the results obtained from absolute and relative approaches are underpinned by differences in the calculated PCR efficiency. By calculating the amplification efficiency from the samples under analysis, comparable results may be obtained without the need for standard curves. We have automated this method to provide a means of streamlining the real-time PCR process, enabling analysis of experimental samples based upon their own reaction kinetics rather than those of artificial standards.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Relative Gene Expression Data Using Real-Time Quantitative PCR and the 2−ΔΔCT Method
Livak, K. J., & Schmittgen, T. D. (2001) · Methods · doi:10.1006/meth.2001.1262 · Cited by 180,860
A new mathematical model for relative quantification in real-time RT-PCR
Pfaffl, M. W. (2001) · Nucleic Acids Research · doi:10.1093/nar/29.9.e45 · Cited by 34,610
Bustin, S. (2000) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0250169 · Cited by 3,872
Mutation of the mouse klotho gene leads to a syndrome resembling ageing
Kuro-o, M., Matsumura, Y., Aizawa, H., Kawaguchi, H., Suga, T., Utsugi, T., Ohyama, Y., Kurabayashi, M., Kaname, T., Kume, E., et al. (1997) · Nature · doi:10.1038/36285 · Cited by 3,837
Quantification of mRNA using real-time reverse transcription PCR (RT-PCR): trends and problems
Bustin, S. (2002) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0290023 · Cited by 2,546
Kinetic PCR Analysis: Real-time Monitoring of DNA Amplification Reactions
Higuchi, R., Fockler, C., Dollinger, G., & Watson, R. (1993) · Nature Biotechnology · doi:10.1038/nbt0993-1026 · Cited by 2,159
Gene quantification using real-time quantitative PCR
Ginzinger, D. G. (2002) · Experimental Hematology · doi:10.1016/s0301-472x(02)00806-8 · Cited by 1,278
Quantitative RT-PCR: Pitfalls and Potential
Freeman, W. M., Walker, S. J., & Vrana, K. E. (1999) · BioTechniques · doi:10.2144/99261rv01 · Cited by 1,147
Schmittgen, T. D., Zakrajsek, B. A., Mills, A. G., Gorn, V., Singer, M. J., & Reed, M. W. (2000) · Analytical Biochemistry · doi:10.1006/abio.2000.4753 · Cited by 1,035
Control Selection for RNA Quantitation
Suzuki, T., Higgins, P. J., & Crawford, D. R. (2000) · BioTechniques · doi:10.2144/00292rv02 · Cited by 875
Regulation of Mammalian Circadian Behavior by Non-rod, Non-cone, Ocular Photoreceptors
Freedman, M. S., Lucas, R. J., Soni, B., von Schantz, M., Muñoz, M., David-Gray, Z., & Foster, R. (1999) · Science · doi:10.1126/science.284.5413.502 · Cited by 848
Quantification using real-time PCR technology: applications and limitations
Klein, D. (2002) · Trends in Molecular Medicine · doi:10.1016/s1471-4914(02)02355-9 · Cited by 762
Regulation of the Mammalian Pineal by Non-rod, Non-cone, Ocular Photoreceptors
Lucas, R. J., Freedman, M. S., Muñoz, M., Garcia-Fernández, J.-M., & Foster, R. G. (1999) · Science · doi:10.1126/science.284.5413.505 · Cited by 525
Liu, W., & Saint, D. A. (2002) · Analytical Biochemistry · doi:10.1006/abio.2001.5530 · Cited by 516
Validation of a quantitative method for real time PCR kinetics
Liu, W., & Saint, D. A. (2002) · Biochemical and Biophysical Research Communications · doi:10.1016/s0006-291x(02)00478-3 · Cited by 359
Control genes in quantitative molecular biological techniques: the variability of invariance
Stürzenbaum, S. R., & Kille, P. (2001) · Comparative Biochemistry and Physiology Part B: Biochemistry and Molecular Biology · doi:10.1016/s1096-4959(01)00440-7 · Cited by 278
Differential expression of c-fos mRNA in rat retinal cells: Regulation by light/dark cycle
Yoshida, K., Kawamura, K., & Imaki, J. (1993) · Neuron · doi:10.1016/0896-6273(93)90053-t · Cited by 129
Diurnal expression of c-fos in the mouse retina
Nir, I., & Agarwal, N. A. (1993) · Molecular Brain Research · doi:10.1016/0169-328x(93)90147-h · Cited by 47
Cited by
Amplification efficiency: linking baseline and bias in the analysis of quantitative PCR data
Ruijter, J. M., Ramakers, C., Hoogaars, W. M. H., Karlen, Y., Bakker, O., van den Hoff, M. J. B., & Moorman, A. F. M. (2009) · Nucleic Acids Research · doi:10.1093/nar/gkp045 · Cited by 3,043
Statistical analysis of real-time PCR data
Yuan, J. S., Reed, A., Chen, F., & Stewart, C. N. (2006) · BMC Bioinformatics · doi:10.1186/1471-2105-7-85 · Cited by 2,195
Real-Time PCR for mRNA Quantitation
Wong, M. L., & Medrano, J. F. (2005) · BioTechniques · doi:10.2144/05391rv01 · Cited by 1,786
Comprehensive Algorithm for Quantitative Real-Time Polymerase Chain Reaction
Zhao, S., & Fernald, R. D. (2005) · Journal of Computational Biology · doi:10.1089/cmb.2005.12.1047 · Cited by 1,303
Fantin, A., Vieira, J. M., Gestri, G., Denti, L., Schwarz, Q., Prykhozhij, S., Peri, F., Wilson, S. W., & Ruhrberg, C. (2010) · Blood · doi:10.1182/blood-2009-12-257832 · Cited by 1,153
Metadata
- Authors
- Peirson, S. N.
- Venue
- Nucleic Acids Research
- Publisher
- Oxford University Press (OUP)
- Published
- 2003-07-15
- Volume
- 31
- Issue
- 14
- Pages
- 73e-73
- ISSN
- 0305-1048 (ISSN-L)
- 1362-4962
- OpenAlex
- W2123247959
- Cited by
- 843
- References
- 18
- FWCI
- 12.33
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.