CoChat

Dialysis improves endothelial function in humans

Cross, Jenny M., Donald, Ann, Vallance, Patrick J., Deanfield, John E., Woolfson, Robin G., MacAllister, Raymond J. · 2001 · Nephrology Dialysis Transplantation
Cited by 84

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Circulating inhibitors of endothelial function have been implicated in the pathogenesis of vascular disease in chronic renal failure. The aim of this study was to determine if lowering the plasma concentration of these and other dialysable toxins improves endothelial function. To do this we compared the acute effects on endothelial function of single episodes of haemodialysis with automated peritoneal dialysis. We hypothesized that endothelial function would improve after dialysis, with a greater effect seen after haemodialysis due to more substantial clearance of endothelial toxins per-treatment. METHODS: Subjects with end-stage renal failure undergoing haemodialysis (n=16) or automated peritoneal dialysis (n=14) were investigated. Endothelial function was determined using vascular ultrasound to measure flow-mediated dilatation of the brachial artery and was compared with the dilatation caused by sublingual glyceryl trinitrate. Endothelial function was assessed before and after a single dialysis treatment. Plasma concentrations of the inhibitors of endothelial function, asymmetric dimethyl-l-arginine and homocysteine were measured. Flow-mediated dilatation was expressed as percentage change from basal diameter and analysed using Student's t test. RESULTS: The plasma concentration of circulating inhibitors of endothelial function was reduced after haemodialysis but not peritoneal dialysis. Haemodialysis increased flow-mediated dilatation from 4.0+/-1.0% to 5.8+/-1.2% (P<0.002). These changes persisted for 5 h but returned to baseline by 24 h. Automated peritoneal dialysis had no acute effect on flow-mediated dilatation (5.9+/-1.1% vs 5.4+/-0.8% after, P>0.5). There were no effects of either dialysis modality on dilatation to glyceryl trinitrate. CONCLUSIONS: Short-term reduction of circulating inhibitors of endothelial function by haemodialysis is associated with increased flow-mediated dilatation. These data suggest that dialysable endothelial toxins have deleterious effects on endothelial function that are rapidly reversible.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/ndt/16.9.1823

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Cross, J. M., Donald, A., Vallance, P. J., Deanfield, J. E., Woolfson, R. G., & MacAllister, R. J.
Venue
Nephrology Dialysis Transplantation
Published
2001-09-01
Volume
16
Issue
9
Pages
1823-1829
ISSN
  • 0931-0509 (ISSN-L)
  • 1460-2385
OpenAlex
W2012969794
Cited by
84
References
1
FWCI
3.63
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.