Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 394

The DOI matches its Crossref record.

Accuracy and reproducibility of biplane two-dimensional echocardiographic measurements of left ventricular dimensions and function

Otterstad, J. E., Froeland, G., St. John Sutton, M., Holme, I. · 1997 · European Heart Journal

Abstract

OBJECTIVE: To investigate sources of variability in serial echocardiographic recordings in a core laboratory we assessed the impact of repeated echo recordings, repeated video measurements and measurements made by different investigators. PATIENTS, METHODS: Two investigators each recorded and analysed two-dimensional echos in 12 individuals (n = 24 in total) three times at one week intervals. Left ventricular end-diastolic and end-systolic volumes were measured using the biplane modified Simpson's rule. Ejection fraction was derived from these volumes and left ventricular mass estimated using the area-length method. The left ventricular spherity index was expressed as the ratio of the short axis area and the long axis area at end-diastole. A video recording from each examination was reexamined twice by both investigators. RESULTS: Deviations between repeated echo recordings and repeated video measurements ranged from -5 to +5% between investigators. A three-way repeated analysis of variance indicated a small, but systematic difference between investigators. Reproducibility, measured by coefficients of variation, ranged from 3-9% for different investigators, 3-6% for repeated video measurements and 7-19% for repeated echo recordings across the different variables. The total variability of all three factors should be considered when the smallest detectable significant change in a variable is assessed. These ranged from 16-28% across the five variables studied, when a 10% error of classification was accepted for a one-sided change in a variable. CONCLUSION: Repeated echo recordings were the dominant component of variation. Two-dimensional echo measurements are reproducible and accurate, but the same investigator should follow the same patients.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/oxfordjournals.eurheartj.a015273

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 394

Metadata

Authors
Otterstad, J. E., Froeland, G., St. John Sutton, M., & Holme, I.
Venue
European Heart Journal
Published
1997-03-01
Volume
18
Issue
3
Pages
507-513
ISSN
  • 0195-668X (ISSN-L)
  • 1522-9645
OpenAlex
W2050477993
Cited by
394
References
0
FWCI
4.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy and reproducibility of biplane two-dimensional echocardiographic measurements of left ventricular dimensions and function. https://app.cochat.ai/papers/10.1093/oxfordjournals.eurheartj.a015273
The paper
Otterstad, J. E., Froeland, G., St. John Sutton, M., & Holme, I. (1997). Accuracy and reproducibility of biplane two-dimensional echocardiographic measurements of left ventricular dimensions and function. European Heart Journal. https://doi.org/10.1093/oxfordjournals.eurheartj.a015273

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.