The DOI matches its Crossref record.
Reliability of Goniometric Measurements
Abstract
This study determined the intratester and intertester variability and reliability of goniometric measurements taken by four physical therapists on upper and lower extremity motions of normal male subjects. The same subjects were measured once weekly for four weeks by testers with varied experience in goniometry. Data were analyzed by analyses of variance with repeated measures. Intratester variation for all measurements was less than intertester variation. Further, intertester variation was less for the three upper extremity motions than for those of the lower extremity. These findings indicate the necessity for using the same tester when effects of treatment are evaluated. When the same tester measures the same movement, increases in joint motion of at least three to four degrees determine improvement for either the upper or lower extremity. When more than one tester, however, measures the same movement, increases in joint motion should exceed five degrees for the upper extremity and six degrees for the lower extremity to determine improvement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Clinical Measurement of Range of Motion
Gajdosik, R. L., & Bohannon, R. W. (1987) · Physical Therapy · doi:10.1093/ptj/67.12.1867 · Cited by 898
Eliasziw, M., Young, S. L., Woodbury, M. G., & Fryday-Field, K. (1994) · Physical Therapy · doi:10.1093/ptj/74.8.777 · Cited by 635
Goniometric Reliability in a Clinical Setting
Rothstein, J. M., Miller, P. J., & Roettger, R. F. (1983) · Physical Therapy · doi:10.1093/ptj/63.10.1611 · Cited by 546
Reliability of five methods for assessing shoulder range of motion
Hayes, K., Walton, J. R., Szomor, Z. L., & Murrell, G. A. (2001) · Australian Journal of Physiotherapy · doi:10.1016/s0004-9514(14)60274-9 · Cited by 402
Goniometric Reliability in a Clinical Setting
Elveru, R. A., Rothstein, J. M., & Lamb, R. L. (1988) · Physical Therapy · doi:10.1093/ptj/68.5.672 · Cited by 379
Reliability and minimal detectible change values for gait kinematics and kinetics in healthy adults
Wilken, J. M., Rodriguez, K. M., Brawner, M., & Darter, B. J. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2011.09.105 · Cited by 337
Witvrouw, E., Bellemans, J., Lysens, R., Danneels, L., & Cambier, D. (2001) · The American Journal of Sports Medicine · doi:10.1177/03635465010290021201 · Cited by 302
Matsas, A., Taylor, N., & McBurney, H. (2000) · Gait & Posture · doi:10.1016/s0966-6362(99)00048-x · Cited by 285
Reliability of shoulder range of motion comparing a goniometer to a digital level
Mullaney, M. J., McHugh, M. P., Johnson, C. P., & Tyler, T. F. (2010) · Physiotherapy Theory and Practice · doi:10.3109/09593980903094230 · Cited by 265
Lyngcoln, A., Taylor, N., Pizzari, T., & Baskus, K. (2005) · Journal of Hand Therapy · doi:10.1197/j.jht.2004.10.008 · Cited by 102
Schlager, A., Ahlqvist, K., Rasmussen-Barr, E., Bjelland, E. K., Pingel, R., Olsson, C., Nilsson-Wikmar, L., & Kristiansson, P. (2018) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-018-2290-5 · Cited by 35
Dominguez-Romero, J. G., Jiménez-Rejano, J. J., Ridao-Fernández, C., & Chamorro-Moriana, G. (2021) · Diagnostics · doi:10.3390/diagnostics11030529 · Cited by 36
Metadata
- Authors
- Boone, D. C., Azen, S. P., Lin, C.-M., Spence, C., Baron, C., & Lee, L.
- Venue
- Physical Therapy
- Publisher
- Oxford University Press (OUP)
- Published
- 1978-11-01
- Volume
- 58
- Issue
- 11
- Pages
- 1355-1360
- ISSN
- 0031-9023 (ISSN-L)
- 1538-6724
- OpenAlex
- W2287737113
- Cited by
- 560
- References
- 0
- FWCI
- 2.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.