Statistical methodology for the concurrent assessment of interrater and intrarater reliability is presented. Application of the methodology is illustrated with an example of one therapist using two goniometers repeatedly to measure knee joint angles. Methods for estimating the coefficients, testing hypotheses, constructing confidence intervals, and computing sample size requirements are provided. In addition, the calculation and clinical interpretation of the standard error of measurement (SEM) are discussed. It is recommended that (1) when both interrater and intrarater reliability are being assessed, a repeated-measures design be used to take advantage of the increased precision gained by using all observations in the statistical analysis, and (2) appropriate statistical tests, confidence intervals, and SEMs always be used in conjunction with the estimated reliability coefficients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Applied Linear Statistical Models
(1997) · Technometrics · doi:10.1080/00401706.1997.10485141 · Cited by 7,185
SCHEFFE, H. (1960) · Soil Science · doi:10.1097/00010694-196006000-00016 · Cited by 5,516
ON THE METHODS AND THEORY OF RELIABILITY
BARTKO, J. J., & CARPENTER, W. T. (1976) · The Journal of Nervous and Mental Disease · doi:10.1097/00005053-197611000-00003 · Cited by 1,310
Clinical Measurement of Range of Motion
Gajdosik, R. L., & Bohannon, R. W. (1987) · Physical Therapy · doi:10.1093/ptj/67.12.1867 · Cited by 898
Experimental design: Procedures for the behavioral sciences (3rd ed.).
Kirk, R. E. (1995) · Cited by 787
An introduction to linear statistical models.
Graybill, F. A. (2013) · Medical Entomology and Zoology · Cited by 740
Sample size requirements for reliability studies
Donner, A., & Eliasziw, M. (1987) · Statistics in Medicine · doi:10.1002/sim.4780060404 · Cited by 699
Self-citationReliability of Goniometric Measurements
Boone, D. C., Azen, S. P., Lin, C.-M., Spence, C., Baron, C., & Lee, L. (1978) · Physical Therapy · doi:10.1093/ptj/58.11.1355 · Cited by 560
Cited by
QUANTIFYING TEST-RETEST RELIABILITY USING THE INTRACLASS CORRELATION COEFFICIENT AND THE SEM
WEIR, J. P. (2005) · Journal of Strength and Conditioning Research · doi:10.1519/00124278-200502000-00038 · Cited by 4,842
Measures of Reliability in Sports Medicine and Science
Hopkins, W. G. (2000) · Sports Medicine · doi:10.2165/00007256-200030010-00001 · Cited by 4,635
“For an example related to human performance tests, see Eliasziw et al.[14] The foregoing formulae for estimating sample size are based on the value of the typical error in the experiment itself.”
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779
Responsiveness of the Numeric Pain Rating Scale in Patients with Low Back Pain
Childs, J. D., Piva, S. R., & Fritz, J. M. (2005) · Spine · doi:10.1097/01.brs.0000164099.92112.29 · Cited by 1,481
Fritz, J. M., & Irrgang, J. J. (2001) · Physical Therapy · doi:10.1093/ptj/81.2.776 · Cited by 1,045
Rankin, G., & Stokes, M. (1998) · Clinical Rehabilitation · doi:10.1191/026921598672178340 · Cited by 856
Three-dimensional ultrasound imaging
Fenster, A., Downey, D. B., & Cardinal, H. N. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/5/201 · Cited by 812
Reliability: what is it, and how is it measured?
Bruton, A., Conway, J. H., & Holgate, S. T. (2000) · Physiotherapy · doi:10.1016/s0031-9406(05)61211-4 · Cited by 763
Chesterton, L. S., Sim, J., Wright, C. C., & Foster, N. E. (2007) · The Clinical Journal of Pain · doi:10.1097/ajp.0b013e318154b6ae · Cited by 691
Thavendiranathan, P., Grant, A. D., Negishi, T., Plana, J. C., Popović, Z. B., & Marwick, T. H. (2013) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.09.035 · Cited by 689
Eurasian Journal of Educational Research
(2021) · Eurasian Journal of Educational Research · doi:10.14689/ejer · Cited by 638
Wyrwich, K. W., Nienaber, N. A., Tierney, W. M., & Wolinsky, F. D. (1999) · Medical Care · doi:10.1097/00005650-199905000-00006 · Cited by 569
Stratford, P. W., & Goldsmith, C. H. (1997) · Physical Therapy · doi:10.1093/ptj/77.7.745 · Cited by 455
Rudd, J. H. F., Myers, K. S., Bansilal, S., Machac, J., Pinto, C. A., Tong, C., Rafique, A., Hargeaves, R., Farkouh, M., Fuster, V., et al. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.050294 · Cited by 444
INTRA- AND INTER-TESTER RELIABILITY AND REFERENCE VALUES FOR HAND STRENGTH
Peolsson, R. H. (2001) · Journal of Rehabilitation Medicine · doi:10.1080/165019701300006524 · Cited by 428
Rudd, J. H. F., Myers, K. S., Bansilal, S., Machac, J., Rafique, A., Farkouh, M., Fuster, V., & Fayad, Z. A. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.05.024 · Cited by 423
Reliability of COP-based postural sway measures and age-related differences
Lin, D., Seol, H., Nussbaum, M. A., & Madigan, M. L. (2008) · Gait & Posture · doi:10.1016/j.gaitpost.2008.01.005 · Cited by 416
Barber, P. A. (2005) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2004.059261 · Cited by 363
The minimal detectable change cannot reliably replace the minimal important difference
Turner, D., Schünemann, H. J., Griffith, L. E., Beaton, D. E., Griffiths, A. M., Critch, J. N., & Guyatt, G. H. (2010) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2009.01.024 · Cited by 356
An Overview on Assessing Agreement with Continuous Measurements
Barnhart, H. X., Haber, M. J., & Lin, L. I. (2007) · Journal of Biopharmaceutical Statistics · doi:10.1080/10543400701376480 · Cited by 319
Puetz, V., Dzialowski, I., Hill, M. D., Subramaniam, S., Sylaja, P. N., Krol, A., O'Reilly, C., Hudon, M. E., Hu, W. Y., Coutts, S. B., et al. (2008) · International Journal of Stroke · doi:10.1111/j.1747-4949.2008.00221.x · Cited by 304
Fletcher, J. P., & Bandy, W. D. (2008) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2008.2680 · Cited by 304
Koppenhaver, S. L., Hebert, J. J., Fritz, J. M., Parent, E. C., Teyhen, D. S., & Magel, J. S. (2009) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2008.06.022 · Cited by 300
Responsiveness of the Neck Disability Index in patients with mechanical neck disorders
Young, B. A., Walker, M. J., Strunce, J. B., Boyles, R. E., Whitman, J. M., & Childs, J. D. (2009) · The Spine Journal · doi:10.1016/j.spinee.2009.06.002 · Cited by 284
Reliability of Ashworth and Modified Ashworth Scales in Children with Spastic Cerebral Palsy
Mutlu, A., Livanelioglu, A., & Gunel, M. K. (2008) · BMC Musculoskeletal Disorders · doi:10.1186/1471-2474-9-44 · Cited by 284
Selected issues in the design and analysis of sport performance research
Atkinson, G., & Nevill, A. M. (2001) · Journal of Sports Sciences · doi:10.1080/026404101317015447 · Cited by 279
Test-retest reliability of trunk accelerometry during standing and walking
Moe-Nilssen, R. (1998) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(98)90231-3 · Cited by 271
Sample Size Determination in Test-Retest and Cronbach Alpha Reliability Estimates
Kennedy, I. (2022) · British Journal of Contemporary Education · doi:10.52589/bjce-fy266hk9 · Cited by 267
Rehabilitative Ultrasound Imaging of the Abdominal Muscles
Teyhen, D. S., Gill, N. W., Whittaker, J. L., Henry, S. M., Hides, J. A., & Hodges, P. (2007) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2007.2558 · Cited by 265
What makes a measurement instrument valid and reliable?
Scholtes, V. A., Terwee, C. B., & Poolman, R. W. (2011) · Injury · doi:10.1016/j.injury.2010.11.042 · Cited by 256
Rehabilitative Ultrasound Imaging: Understanding the Technology and Its Applications
Whittaker, J. L., Teyhen, D. S., Elliott, J. M., Cook, K., Langevin, H. M., Dahl, H. H., & Stokes, M. (2007) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2007.2350 · Cited by 250
Miller, W. C., Deathe, A. B., & Speechley, M. (2003) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(02)04807-4 · Cited by 232
Assessing observer variability: a user’s guide
Popović, Z. B., & Thomas, J. D. (2017) · Cardiovascular Diagnosis and Therapy · doi:10.21037/cdt.2017.03.12 · Cited by 225
Smith, H. C., Johnson, R. J., Shultz, S. J., Tourville, T., Holterman, L. A., Slauterbeck, J., Vacek, P. M., & Beynnon, B. D. (2012) · The American Journal of Sports Medicine · doi:10.1177/0363546511429776 · Cited by 224
Hyperpolarized 3He Magnetic Resonance Functional Imaging Semiautomated Segmentation
Kirby, M., Heydarian, M., Svenningsen, S., Wheatley, A., McCormack, D. G., Etemad-Rezai, R., & Parraga, G. (2012) · Academic Radiology · doi:10.1016/j.acra.2011.10.007 · Cited by 214
What sample sizes for reliability and validity studies in neurology?
Hobart, J. C., Cano, S. J., Warner, T. T., & Thompson, A. J. (2012) · Journal of Neurology · doi:10.1007/s00415-012-6570-y · Cited by 200
On deconvolution with repeated measurements
Delaigle, A., Hall, P., & Meister, A. (2008) · The Annals of Statistics · doi:10.1214/009053607000000884 · Cited by 197
“…in a social science context; of Andersen, Bro and Brockhoff (2003), on nuclear magnetic reasonance; of Bland and Altman (1986), on lung function; of Eliasziw et al. (1994), on physiotherapy for the knee; of Oman, Meir and Haim (1999), relating to kidney function; and of Dunn (1989), a…”
BackgroundVascular Inflammation in Subclinical Atherosclerosis Detected by Hybrid PET/MRI
Fernández-Friera, L., Fuster, V., López-Melgar, B., Oliva, B., Sánchez-González, J., Macías, A., Pérez-Asenjo, B., Zamudio, D., Alonso-Farto, J. C., España, S., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.12.075 · Cited by 168
Berth-Jones, J., Grotzinger, K., Rainville, C., Pham, B., Huang, J., Daly, S., Herdman, M., Firth, P., & Hotchkiss, K. (2006) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2006.07389.x · Cited by 165
The validity of upper-limb neurodynamic tests for detecting peripheral neuropathic pain.
Nee, R. J., Jull, G. A., Vicenzino, B., & Coppieters, M. W. (2012) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2012.3988 · Cited by 171
Reliability and validity of the modified functional reach test at the sub-acute stage post-stroke
Katz-Leurer, M., Fisher, I., Neeb, M., Schwartz, I., & Carmeli, E. (2009) · Disability and Rehabilitation · doi:10.1080/09638280801927830 · Cited by 162
“It is known that too small sample size might yield an imprecise estimate of the reliability coefficient, which is indicated by an excessively wide CI [26].”
BackgroundAssessment of the degree of pelvic tilt within a normal asymptomatic population
Herrington, L. (2011) · Manual Therapy · doi:10.1016/j.math.2011.04.006 · Cited by 87
“96 (O2 (SEM)) (Eliasziw et al., 1994).”
Hartling, L., Bond, K., Santaguida, P. L., Viswanathan, M., & Dryden, D. M. (2011) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2011.01.010 · Cited by 69
Metadata
- Authors
- Eliasziw, M., Young, S. L., Woodbury, M. G., & Fryday-Field, K.
- Venue
- Physical Therapy
- Publisher
- Oxford University Press (OUP)
- Published
- 1994-08-01
- Volume
- 74
- Issue
- 8
- Pages
- 777-788
- ISSN
- 0031-9023 (ISSN-L)
- 1538-6724
- OpenAlex
- W2097419280
- Cited by
- 635
- References
- 15
- FWCI
- 5.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.