The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Recruitment Patterns in Human Skeletal Muscle During Electrical Stimulation
Abstract
Electromyostimulation (EMS) incorporates the use of electrical current to activate skeletal muscle and facilitate contraction. It is commonly used in clinical settings to mimic voluntary contractions and enhance the rehabilitation of human skeletal muscles. Although the beneficial effects of EMS are widely accepted, discrepancies concerning the specific responses to EMS versus voluntary actions exist. The unique effects of EMS have been attributed to several mechanisms, most notably a reversal of the recruitment pattern typically associated with voluntary muscle activation. This perspective outlines the authors' contention that electrical stimulation recruits motor units in a nonselective, spatially fixed, and temporally synchronous pattern. Furthermore, it synthesizes the evidence that supports the contention that this recruitment pattern contributes to increased muscle fatigue when compared with voluntary actions. The authors believe the majority of evidence suggests that EMS-induced motor unit recruitment is nonselective and that muscle fibers are recruited without obvious sequencing related to fiber types.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
FUNCTIONAL SIGNIFICANCE OF CELL SIZE IN SPINAL MOTONEURONS
Henneman, E., Somjen, G., & Carpenter, D. O. (1965) · Journal of Neurophysiology · doi:10.1152/jn.1965.28.3.560 · Cited by 2,294
Chemical energetics of slow- and fast-twitch muscles of the mouse.
Crow, M. T., & Kushmerick, M. J. (1982) · The Journal of general physiology · doi:10.1085/jgp.79.1.147 · Cited by 549
Motor-unit discharge rates in maximal voluntary contractions of three human muscles
Bellemare, F., Woods, J. J., Johansson, R., & Bigland-Ritchie, B. (1983) · Journal of Neurophysiology · doi:10.1152/jn.1983.50.6.1380 · Cited by 368
Motor unit behaviour and contractile changes during fatigue in the human first dorsal interosseus
Carpentier, A., Duchateau, J., & Hainaut, K. (2001) · The Journal of Physiology · doi:10.1111/j.1469-7793.2001.00903.x · Cited by 326
Mapping of electrical muscle stimulation using MRI
Adams, G. R., Harris, R. T., Woodard, D., & Dudley, G. A. (1993) · Journal of Applied Physiology · doi:10.1152/jappl.1993.74.2.532 · Cited by 322
Bélanger, M., Stein, R. B., Wheeler, G. D., Gordon, T., & Leduc, B. (2000) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2000.7170 · Cited by 318
Effect of varying exercise intensity on glycogen depletion in human muscle fibres
VØLLESTAD, N. K., & BLOM, P. C. S. (1985) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1985.tb07735.x · Cited by 274
Inference of motor unit recruitment order in voluntary and electrically elicited contractions
Knaflitz, M., Merletti, R., & De Luca, C. J. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.4.1657 · Cited by 251
A COMPARISON OF THE CHARACTERISTICS OF AXONS THROUGH THEIR INDIVIDUAL ELECTRICAL RESPONSES
Blair, E. A., & Erlanger, J. (1933) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1933.106.3.524 · Cited by 247
Feiereisen, P., Duchateau, J., & Hainaut, K. (1997) · Experimental Brain Research · doi:10.1007/pl00005610 · Cited by 217
Research works printed but not linked: 2
- Sinacore, 1990, Type II fiber activation with electrical stimulation: a preliminary report, Phys Ther, 70, 416, 10.1093/ptj/70.7.416 · doi:10.1093/ptj/70.7.416
- Han, 2001, Reserve capacity for ATP consumption during isometric contraction in human skeletal muscle fibers, J Appl Physiol, 90, 657, 10.1152/jappl.2001.90.2.657 · doi:10.1152/jappl.2001.90.2.657
Cited by
Spruit, M. A., Singh, S. J., Garvey, C., ZuWallack, R., Nici, L., Rochester, C., Hill, K., Holland, A. E., Lareau, S. C., Man, W. D.-C., et al. (2013) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201309-1634st · Cited by 3,938
Physiological and methodological considerations for the use of neuromuscular electrical stimulation
Maffiuletti, N. A. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1502-y · Cited by 651
Motor unit recruitment during neuromuscular electrical stimulation: a critical appraisal
Bickel, C. S., Gregory, C. M., & Dean, J. C. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2128-4 · Cited by 391
Self-citationFunctional Electrical Stimulation
(2008) · IEEE Control Systems · doi:10.1109/mcs.2007.914689 · Cited by 336
Crameri, R. M., Aagaard, P., Qvortrup, K., Langberg, H., Olesen, J., & Kjær, M. (2007) · The Journal of Physiology · doi:10.1113/jphysiol.2007.128827 · Cited by 319
Differences in quadriceps muscle strength and fatigue between lean and obese subjects
Maffiuletti, N. A., Jubeau, M., Munzinger, U., Bizzini, M., Agosti, F., De Col, A., Lafortuna, C. L., & Sartorio, A. (2007) · European Journal of Applied Physiology · doi:10.1007/s00421-007-0471-2 · Cited by 284
Neuromuscular electrical stimulation: implications of the electrically evoked sensory volley
Bergquist, A. J., Clair, J. M., Lagerquist, O., Mang, C. S., Okuma, Y., & Collins, D. F. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2087-9 · Cited by 271
Botter, A., Oprandi, G., Lanfranco, F., Allasia, S., Maffiuletti, N. A., & Minetto, M. A. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2093-y · Cited by 260
A mm-Sized Wireless Implantable Device for Electrical Stimulation of Peripheral Nerves
Charthad, J., Chang, T. C., Liu, Z., Sawaby, A., Weber, M. J., Baker, S., Gore, F., Felt, S. A., & Arbabian, A. (2018) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2018.2799623 · Cited by 230
Coggan, A. R., Leibowitz, J. L., Kadkhodayan, A., Thomas, D. P., Ramamurthy, S., Spearie, C. A., Waller, S., Farmer, M., & Peterson, L. R. (2015) · Nitric Oxide · doi:10.1016/j.niox.2014.08.014 · Cited by 159
Rapid Force Production in Children and Adults: Mechanical and Neural Contributions
WAUGH, C. M., KORFF, T., FATH, F., & BLAZEVICH, A. J. (2013) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31827a67ba · Cited by 97
Selfslagh, A., Shokur, S., Campos, D. S. F., Donati, A. R. C., Almeida, S., Yamauti, S. Y., Coelho, D. B., Bouri, M., & Nicolelis, M. A. L. (2019) · Scientific Reports · doi:10.1038/s41598-019-43041-9 · Cited by 78
Maffiuletti, N. A., Green, D. A., Vaz, M. A., & Dirks, M. L. (2019) · Frontiers in Physiology · doi:10.3389/fphys.2019.01031 · Cited by 50
(2015) · PubMed Central · Cited by 33
WIDJAJA, F., SHEE, C. Y., ANG, W. T., AU, W. L., & POIGNET, P. (2011) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519411004344 · Cited by 14
Metadata
- Authors
- Gregory, C. M., & Bickel, C. S.
- Venue
- Physical Therapy
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-04-01
- Volume
- 85
- Issue
- 4
- Pages
- 358-364
- ISSN
- 0031-9023 (ISSN-L)
- 1538-6724
- OpenAlex
- W2163284095
- Cited by
- 612
- References
- 30
- FWCI
- 9.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.