Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 181

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Heart rate variability measurements and the prediction of ventricular arrhythmias

Reed, M.J., Robertson, C.E., Addison, P.S.·2005·QJM

Abstract

From the Department of Emergency Medicine, Royal Infirmary of Edinburgh, Edinburgh, and 1Cardiodigital Ltd, Elvingston Science Centre, Gladsmuir, UK Heart rate variability (HRV) is the temporal variation between sequences of consecutive heartbeats. On a standard electrocardiogram (ECG), the maximum upwards deflection of a normal QRS complex is at the peak of the R wave (Figure 1), and the duration between two adjacent R wave peaks is termed the R-R interval. The ECG signal requires editing before HRV analysis can be performed, a process requiring the removal of all non-sinus-node-originating beats. The resulting period between adjacent QRS complexes resulting from sinus node depolarizations is termed the N-N (normal-normal) interval.1 HRV is the measurement of the variability of the N-N intervals. ... Although counter-intuitive, it is possible that HRV confers a survival advantage. Any system exhibiting intrinsic variability is primed to respond rapidly and appropriately to demands placed upon it. HRV is a measure of the balance between sympathetic mediators of heart rate (HR) (i.e. the effect of epinephrine and norepinephrine, released from sympathetic nerve fibres, acting on the sino-atrial and atrio-ventricular nodes), which increase the rate of cardiac contraction and facilitate conduction at the atrio-ventricular node, and parasympathetic mediators of HR (i.e. the influence of acetylcholine, released by the parasympathetic nerve fibres, acting on the sino-atrial and atrio-ventricular nodes), leading to a decrease in the HR and a slowing of conduction at the atrio-ventricular node. Sympathetic mediators appear to exert their influence over longer time periods and are reflected in the low frequency power (LFP) of the HRV spectrum (between 0.04 Hz and 0.15 Hz.2,3 Vagal mediators exert their influence more quickly on the heart, and principally affect the high frequency power (HFP) of the HRV spectrum (between 0.15 Hz and 0.4 Hz).4 Thus, at any point in time, the LFP:HFP ratio is a proxy for the sympatho-vagal balance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/qjmed/hci018

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 181

Metadata

Authors
Reed, M. J., Robertson, C. E., & Addison, P. S.
Venue
QJM
Published
2005-01-25
Volume
98
Issue
2
Pages
87-95
ISSN
  • 0033-5622 (ISSN-L)
  • 1460-2725
  • 1460-2393
OpenAlex
W2054676932
Cited by
181
References
5
FWCI
2.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Heart rate variability measurements and the prediction of ventricular arrhythmias. https://app.cochat.ai/papers/10.1093/qjmed/hci018
The paper
Reed, M. J., Robertson, C. E., & Addison, P. S. (2005). Heart rate variability measurements and the prediction of ventricular arrhythmias. QJM. https://doi.org/10.1093/qjmed/hci018

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.