This article describes the system of regulation and practical guidance that has been developed in the UK for implementing the requirement in the EC Medical Exposure Directive that all Member States shall promote the establishment and use of diagnostic reference levels (DRLs) for medical X-ray examinations. In particular, it describes the role of two national patient dose databases maintained by NRPB, which provide important sources of information on which formally adopted numerical values for 'national DRLs' will be based. One database deals with radiographic and fluoroscopic examinations and the recommended 'national reference doses' from the latest review of this database are discussed. The other database deals specifically with computed tomography (CT) examinations, which now account for 50% of the collective dose to the UK population from all medical X rays and are consequently of particular radiation protection concern. The first analysis of this CT database is still underway, but some encouraging indications of a reduction in patient dose for some CT examinations are reported. Progress in formally adopting numerical values for 'national DRLs', as required by the UK regulations, and the provision of authoritative guidance on the implementation of DRLs at the local level, are also discussed.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The United Kingdom possesses a developed DRL system overseen by the UK Health Security Agency (UKHSA).109,110”
From Computed Tomography Diagnostic Reference Levels Worldwide and in Jordan: Implications for Patient Dose Reduction (2026) · cites this paper as [109]
Citations
Cites
Wall, B. F., & Hart, D. (1997) · The British Journal of Radiology · doi:10.1259/bjr.70.833.9227222 · Cited by 412
Self-citationDoses to Patients from Medical X-ray Examinations in the UK - 2000 Review
Hart, D., Hillier, M., & Wall, B. F. (2002) · OpenGrey (Institut de l'Information Scientifique et Technique) · Cited by 201
Self-citation
Research works printed but not linked: 1
- Hart, D., Hillier, M. C., Wall, B. F., Shrimpton, P. C. and Bungay, D. Doses to patients from medical X-ray examinations in the UK—1995 Review. NRPB-R289 (Chilton: NRPB) (1996).
Cited by
Singh, S., Kalra, M. K., Moore, M. A., Shailam, R., Liu, B., Toth, T. L., Grant, P. E., & Westra, S. J. (2009) · Radiology · doi:10.1148/radiol.2521081554 · Cited by 202
“However, radiation doses observed with the use of the new protocols were well within the reference dose levels described in previous studies from Great Britain (20,21).”
ResultRadiation Doses in Consecutive CT Examinations from Five University of California Medical Centers
Smith-Bindman, R., Moghadassi, M., Wilson, N., Nelson, T. R., Boone, J. M., Cagnon, C. H., Gould, R., Hall, D. J., Krishnam, M., Lamba, R., et al. (2015) · Radiology · doi:10.1148/radiol.2015142728 · Cited by 127
Balter, S., Miller, D. L., Vano, E., López, P. O., Bernardi, G., Cotelo, E., Faulkner, K., Nowotny, R., Padovani, R., & Ramirez, A. (2008) · Medical Physics · doi:10.1118/1.2829868 · Cited by 119
Muhogora, W. E., Ahmed, N. A., Almosabihi, A., AlSuwaidi, J. S., Beganović, A., Ciraj‐Bjelac, O., Kabuya, F. K., Krisanachinda, A., Milaković, M., Mukwada, G., et al. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.3039 · Cited by 115
“There is growing evidence that comparison of dose values with diagnostic reference levels has led to a decrease in patient doses [12–19], and therefore the use of this optimization tool should be widely promoted.”
BackgroundOptimisation in general radiography
Martin, C. (2007) · Biomedical Imaging and Intervention Journal · doi:10.2349/biij.3.2.e18 · Cited by 100
Updated Australian diagnostic reference levels for adult CT
Lee, K. L., Beveridge, T., Sanagou, M., & Thomas, P. (2020) · Journal of Medical Radiation Sciences · doi:10.1002/jmrs.372 · Cited by 75
Muhogora, W. E., Ahmed, N. A., Beganovic, A., Benider, A., Ciraj-Bjelac, O., Gershan, V., Gershkevitsh, E., Grupetta, E., Kharita, M. H., Manatrakul, N., et al. (2009) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncp144 · Cited by 56
Radiation dosimetry for diagnostic medical exposures
Martin, C. J. (2007) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncm495 · Cited by 61
D’Ercole, L., Thyrion, F. Z., Bocchiola, M., Mantovani, L., & Klersy, C. (2010) · Physica Medica · doi:10.1016/j.ejmp.2010.10.008 · Cited by 56
Brat, H. G., Zanca, F., Montandon, S., Racine, D., Rizk, B., Eric, M., & Fournier, D. (2019) · European Radiology · doi:10.1007/s00330-019-06257-x · Cited by 54
Australian diagnostic reference levels for multi detector computed tomography
Hayton, A., Wallace, A. B., Marks, P., Edmonds, K., Tingey, D., & Johnston, P. N. (2013) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/s13246-013-0180-6 · Cited by 48
Management of patient dose in radiology in the UK
Martin, C. J. (2011) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncr386 · Cited by 46
Determining and updating PET/CT and SPECT/CT diagnostic reference levels: A systematic review
Alkhybari, E. M., McEntee, M. F., Brennan, P., Willowson, K. P., Hogg, P., & Kench, P. L. (2018) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncy113 · Cited by 31
Gibson, D. A. J., Moorin, R. E., Semmens, J. B., & Holman, D. (2014) · Australian and New Zealand Journal of Public Health · doi:10.1111/1753-6405.12278 · Cited by 28
Hung, K. F., Hui, L., Yeung, A. W. K., Jacobs, R., Leung, Y. Y., & Bornstein, M. M. (2022) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20200529 · Cited by 24
Local Diagnostic Reference Levels for Typical Radiographic Procedures
Tonkopi, E., Daniels, C., Gale, M. J., Schofield, S. C., Sorhaindo, V. A., & VanLarkin, J. L. (2011) · Canadian Association of Radiologists Journal · doi:10.1016/j.carj.2011.02.004 · Cited by 24
“In the United Kingdom, the Radiation Protection Division of the Health Protection Agency has reevaluated national reference levels for common procedures every 5 years [6,7].”
BackgroundDIAGNOSTIC REFERENCE LEVELS IN CARDIAC COMPUTED TOMOGRAPHY ANGIOGRAPHY: A SYSTEMATIC REVIEW
Alhailiy, A. B., Brennan, P., McEntee, M. F., Kench, P. L., & Ryan, E. A. (2017) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncx075 · Cited by 21
“It specifies the use of the data of at least ten patients, with a mean sample weight of 70 kg (±5 kg) for establishing national DRLs for CT procedures((18)).”
MethodApproaches to aspects of optimisation of protection in diagnostic radiology in six continents
Martin, C. J., Heron, J. L., Borrás, C., Sookpeng, S., & Ramirez, G. E. (2013) · Journal of Radiological Protection · doi:10.1088/0952-4746/33/4/711 · Cited by 20
Hayton, A., & Wallace, A. B. (2016) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/s13246-016-0431-4 · Cited by 18
Patient dose measurements in diagnostic radiology procedures in Montenegro
Milatović, A., Ciraj‐Bjelac, O., Ivanović, S. R., Jovanović, S., & Spasić-Jokić, V. (2011) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncr317 · Cited by 16
Radiation dosimetry assessment of routine CT scanning protocols used in Western Australia
Moorin, R. E., Forsyth, R. K., Gibson, D. A. J., & Fox, R. A. (2013) · Journal of Radiological Protection · doi:10.1088/0952-4746/33/2/295 · Cited by 15
Maxwell, S. J., Fox, R. A., McRobbie, D. W., Bulsara, M. K., Doust, J. A., O'Leary, P. C., Slavotinek, J., Stubbs, J. H., & Moorin, R. E. (2019) · PLoS ONE · doi:10.1371/journal.pone.0217816 · Cited by 14
ADULT CT EXAMINATIONS IN ALGERIA: TOWARDS UPDATING NATIONAL DIAGNOSTIC REFERENCE LEVELS
Khelassi-Toutaoui, N., Merad, A., Tsapaki, V., Meddad, F., Sakhri-Brahimi, Z., Guedioura, D., & Saadi, S. (2020) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncaa116 · Cited by 14
DOSIMETRY OF ADULT AND PEDIATRIC PATIENTS FOR COMMON DIGITAL RADIOGRAPHY EXAMINATIONS
Rana, B. S., Kumar, S., Sandhu, I. S., & Singh, N. P. (2017) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncx293 · Cited by 13
Xu, J., Wang, X., Xiao, H., & Xu, J. (2019) · Medical Science Monitor · doi:10.12659/msm.917980 · Cited by 12
Validation of a large-scale audit technique for CT dose optimisation
Wood, T. J., Davis, A. W., Moore, C. S., Beavis, A. W., & Saunderson, J. (2011) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncr434 · Cited by 12
Reduction of scattered radiation dose by X-ray shielding during mammography
Koo, B.-Y., & Lee, K.-S. (2020) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2020.109111 · Cited by 11
Performance of medical radiographic X-ray systems in Greece for the time period 1998–2004
Economides, S., Hourdakis, C. J., Kalivas, N., Kalathaki, M., Simantirakis, G., Tritakis, P., Manousaridis, G., Vogiatzi, S., Kipouros, P., Boziari, A., et al. (2007) · Physica Medica · doi:10.1016/j.ejmp.2007.10.001 · Cited by 10
Papageorgiou, E., Tsapaki, V., Tsalafoutas, I. A., Maurikou, E., Kottou, S., Orfanos, A., Karidas, G., Fidanis, T., Zafiriadou, E., & Neofotistou, V. (2007) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncm136 · Cited by 9
Gibson, D. A. J., Moorin, R. E., & Holman, C. D. J. (2014) · BMC Health Services Research · doi:10.1186/s12913-014-0526-0 · Cited by 8
Assessment of Patient Doses in CR Examinations Throughout a Large Health Region
Thakur, Y., Bjarnason, T. A., Hammerstrom, K., Marchinkow, L. O., Koch, T., & Aldrich, J. E. (2011) · Journal of Imaging Informatics in Medicine · doi:10.1007/s10278-011-9390-1 · Cited by 8
“Values are derived from large surveys, taken as either the 75th [12–14] or 80th [15] percentile of effective dose range.”
MethodDIAGNOSTIC REFERENCE LEVELS AND COMPLEXITY INDICES IN INTERVENTIONAL RADIOLOGY
Vosou, M., Spiliοpoulos, S., Palialexis, K., Antonakos, I., & EFSTATHOPOULOS, E. P. (2022) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncac267 · Cited by 7
Evaluating data capture methods for the establishment of diagnostic reference levels in CT scanning
Moorin, R. E., Gibson, D. A. J., Forsyth, R. K., Bulsara, M. K., & Holman, C. D. J. (2013) · European Journal of Radiology · doi:10.1016/j.ejrad.2013.11.003 · Cited by 6
“Keywords: CT scan, Radiation Dosage, Radiation Dosimetry, Survey Methods, Radiology Information Systems”
MethodDiagnostic reference levels in intraoral radiology: from the laboratory to clinical practice
Alcaraz, M., Velasco, E., Beneyto, Y. M., Velasco, F., Parra, C., & Canteras, M. (2010) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncq131 · Cited by 6
Cho, P.-K. (2012) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncs264 · Cited by 5
Moorin, R. E., Gibson, D. A. J., Forsyth, R. K., & Fox, R. A. (2014) · PLoS ONE · doi:10.1371/journal.pone.0097691 · Cited by 5
Retrospective Patient Dose Analysis of Ghana’s First Direct Digital Radiography System
Inkoom, S., Togobo, J., Emi-Reynolds, G., Oddoye, A., Ntiri, T. O., & Gyekye, P. K. (2012) · Health Physics · doi:10.1097/hp.0b013e3182475a76 · Cited by 4
“…NDRL (President of the Republic Decree 187/2000), Germany EBundesamt fur Strahlenschutz, 2003, with the exception of lumbar spine AP, abdomen AP, and pelvis AP, which exceeded the DRLs of UK (Wall 2005)^, U.S. (Gray et al. 2005), and IAEA 135Retrospective patient dose analysis c S. INKOOM ET AL.”
BackgroundResultКапырина, Ю. Н., Пузырев, В. Г., Водоватов, А. В., Комиссаров, М. И., & Алешин, И. Ю. (2023) · Medicine and health care organization · doi:10.56871/mhco.2023.13.88.009 · Cited by 3
Patient doses in radiographic examinations in Western and Eastern Azerbyjan provinces of Iran
Minaei, S. E., Firouzi, F., & Khosravi, H. R. (2014) · Archives of Advances in Biosciences · doi:10.22037/jps.v5i3.7400 · Cited by 3
“It is proved that comparison of dose level with DRLs has led to a drop in patient dose [8-10].”
BackgroundRadiation Exposure in Paediatric Orthopaedic Trauma Surgery
Jamieson, K., & Barker, S. L. (2025) · Cureus · doi:10.7759/cureus.96053 · Cited by 2
“For quality assurance, IR(ME)R recommends establishing diagnostic reference levels (DRLs), which serve as benchmarks indicating expected radiation doses for specific procedures [10].”
Impacto de la radiología digital en la dosis de referencia de radiología intraoral española
Hidalgo, F. V. (2016) · Digitum: Institutional Repository of the University of Murcia (University of Murcia) · Cited by 2
Stam, R. (2013) · Rivm Repository (Netherlands National Institute for Public Health and the Environment) · Cited by 1
Radiation dose dependence on MDCT platform and acquisition protocols for CT coronary angiography
Wallace, A. B. (2012) · Journal of Medical Imaging and Radiation Oncology · doi:10.1111/j.1754-9485.2011.02338.x · Cited by 1
Oglat, A., Shdaifat, S., Sayah, M., Abukonna, A., & Khogali, W. (2026) · Drug, Healthcare and Patient Safety · doi:10.2147/dhps.s595721
Continuous Improvement of the Diagnostic Reference Levels for Medical X-Ray Radiography
李, 鹏. (2013) · Medical Diagnosis · doi:10.12677/md.2013.31001
Investigation into Radiation Doses to Patient During Diagnostic Imaging
Khalid, D. (2013) · Journal of Zankoy Sulaimani - Part A · doi:10.17656/jzs.10270
Development of a Phantom for Low Dose Mammography
Kim, C. G. (2020) · Medico-Legal Update · doi:10.37506/mlu.v20i1.653
Moorin, R. (2014) · PubMed
Metadata
- Authors
- Wall, B. F.
- Affiliations
- National Radiological Protection Board (GB)
- Corresponding author
- Wall, B. F.
- Venue
- Radiation Protection Dosimetry
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-05-17
- Volume
- 114
- Issue
- 1-3
- Pages
- 183-187
- ISSN
- 0144-8420 (ISSN-L)
- 1742-3406
- OpenAlex
- W2099209712
- Cited by
- 46
- References
- 2
- Citations by year
- 2026: 1 · 2025: 1 · 2023: 1 · 2022: 2 · 2020: 4 · 2019: 3 · 2018: 1 · 2017: 2 · 2016: 1 · 2015: 1 · 2014: 4 · 2013: 7 · 2012: 3
- FWCI
- 1.53
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Radiation Protection Dosimetry (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
- Keywords
- diagnostic reference levels, computed tomography, fluoroscopy, radiography, collective dose, radiation protection regulation
- MeSH terms
- Adult, Child, Child, Preschool, Diagnostic Imaging, United Kingdom, Humans, Infant, Newborn, Radiation Dosage, Radiation Protection, Radiography, Radiometry, Reference Standards, Tomography, X-Ray Computed, X-Rays, Databases as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.