Cited by 18Radiation Dose and ImagingAdvanced Radiotherapy TechniquesRadiology practices and education

Determination of national diagnostic reference levels in computed tomography examinations of Iran by a new quality control-based dose survey method

Sohrabi, Mehdi, Parsi, Masoumeh, Mianji, Fereidoun·2018·Radiation Protection Dosimetry

Abstract

National diagnostic reference levels (NDRLs) of Iran were determined for the four most common CT examinations including head, sinus, chest and abdomen/pelvis. A new 'quality control (QC)-based dose survey method', as developed by us, was applied to 157 CT scanners in Iran (2014-15) with different slice classes, models and geographic spread across the country. The NDRLs for head, sinus, chest and abdomen/pelvis examinations are 58, 29, 12 and 14 mGy for CTDIVol and 750, 300, 300 and 650 mGy.cm for DLP, respectively. The 'QC-based dose survey method' was further proven that it is a simple, accurate and practical method for a time and cost-effective NDRLs determination. One effective approach for optimization of the CT examination protocols at the national level is the provision of an adequate standardized training of the radiologists, technicians and medical physicists on the patient radiation protection principles and implementation of the DRL concept in clinical practices.

Integrity signals

Registry

Crossref · 10.1093/rpd/ncx252

Cites

16 of 16 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Sohrabi, M., Parsi, M., & Mianji, F.
Affiliations
  • Amirkabir University of Technology (IR)
  • Nuclear Science and Technology Research Institute (IR)
Corresponding author
Sohrabi, Mehdi
Venue
Radiation Protection Dosimetry
Published
2017-11-10
Volume
179
Issue
3
Pages
206-215
ISSN
  • 0144-8420 (ISSN-L)
  • 1742-3406
OpenAlex
W2767885796
Cited by
18
References
16
Citations by year
2026: 1 · 2025: 1 · 2024: 6 · 2022: 1 · 2021: 3 · 2020: 1 · 2019: 3 · 2018: 2
FWCI
1.26
Type
journal article
Language
en
Open access
closed
Locations
  • Radiation Protection Dosimetry (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • European Commission
  • Amirkabir University of Technology
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
Keywords
CT radiation dose, CT scanner, dose-length product, CTDIvol, head CT, sinus CT, chest CT, radiation protection, CT protocol optimization, Iran
MeSH terms
Head, Humans, Iran, Pelvis, Quality Control, Surveys and Questionnaires, Radiation Dosage, Radiation Protection, Radiography, Abdominal, Reference Standards, Reference Values, Sinoatrial Node, Radiography, Thoracic, Tomography, X-Ray Computed, Tomography Scanners, X-Ray Computed, Phantoms, Imaging

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review