CoChat

Impairment of Error Monitoring Following Sleep Deprivation

Open access
Tsai, Ling-Ling, Young, Hung-Yu, Hsieh, Shulan, Lee, Chia-Shun · 2005 · Sleep
Cited by 97

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

STUDY OBJECTIVES: To verify if error monitoring, involving detection and remedial actions, is affected by sleep deprivation. DESIGN: Event-related brain potentials (ERPs) and electroencephalogram spectrum during performance of Flanker task were obtained in a within-subject, counter-balanced, repeated-measures design. SETTING: Sleep deprivation and data collection were conducted in a laboratory setting. PARTICIPANTS: Sixteen young healthy adults (7 women, 18-23 years old) INTERVENTIONS: Performance and electroencephalogram data were collected after normal sleep and sleep deprivation. MEASUREMENTS AND RESULTS: Compared to normal sleep, 1 night of sleep deprivation resulted in slower and more varied reaction times, more response errors and omissions, and impaired posterror adjustments to response accuracy. Concomitantly, 2 error-related ERPs, error-related negativity and Pe, showed reduced amplitude measurements after sleep deprivation. Conversely, conflict monitoring as expressed behaviorally and by the N2 component of the ERP was not attenuated by sleep deprivation. Ten of the sixteen participants maintained similar accuracy levels under both sleep conditions, although they still showed reduced error-related negativity and error positivity amplitude measurements and impaired error remedial actions for accuracy. Electroencephalogram spectral activity at beta and theta frequency bands was related to response correctness on subsequent trials but not related to that of preceding trials under both sleep conditions. CONCLUSIONS: One night of sleep deprivation impaired both the error detection and error remedial actions and highlighted the inability to avoid making errors again after erroneous responses were already made. The results showed that a vicious cycle occurred between performance deterioration and impairment of error-remedial mechanisms that inevitably led to making more successive errors.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/sleep/28.6.707

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

See all 97

Metadata

Authors
Tsai, L.-L., Young, H.-Y., Hsieh, S., & Lee, C.-S.
Venue
Sleep
Published
2005-06
Volume
28
Issue
6
Pages
707-713
ISSN
  • 0161-8105 (ISSN-L)
  • 1550-9109
OpenAlex
W2104538665
Cited by
97
References
12
FWCI
4.58
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Impairment of Error Monitoring Following Sleep Deprivation. https://app.cochat.ai/papers/10.1093/sleep/28.6.707
The paper
Tsai, L.-L., Young, H.-Y., Hsieh, S., & Lee, C.-S. (2005). Impairment of Error Monitoring Following Sleep Deprivation. Sleep. https://doi.org/10.1093/sleep/28.6.707

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.