STUDY OBJECTIVES: Total sleep time (TST), sleep efficiency (SE), and wake after sleep onset (WASO) as assessed by actigraphy gathered in 3 different modes were compared to polysomnography (PSG) measurements. Each mode was compared to PSG to determine which was more accurate. Associations of the difference in TST measurement with demographics and sleep characteristics were examined. DESIGN: Observational study. SETTING: Community-based. PARTICIPANTS: Sixty-eight women (mean age 81.9 years) from the latest visit of the Study of Osteoporotic Fractures who were concurrently measured with PSG and actigraphy. INTERVENTIONS: N/A. MEASUREMENTS AND RESULTS: In-home 12-channel PSG was gathered along with actigraphy data in 3 modes: proportional integration mode (PIM), time above threshold (TAT) and zero crossings mode (ZCM). The PIM mode corresponded better to PSG, with a mean overestimation of TST of 17.9 min. For the PIM mode, the estimation of TST and SE by PSG and actigraphy significantly differed (P < 0.01), while the estimation of WASO was similar (P = 0.27). The intraclass correlation between the 2 procedures was moderate to high (PIM mode: TST 0.76; SE 0.61; WASO 0.58). On average, the PIM mode underestimated TST by 68 min for those who slept < or = 5 hr, overestimated TST by 31 min for those with SE < 70%, and underestimated TST by 24 min for self-reported poor sleepers (P < 0.05). CONCLUSIONS: Sleep parameters from actigraphy corresponded reasonably well to PSG in this population, with the PIM mode of actigraphy correlating highest. Those with poor sleep quality had the largest measurement error between the 2 procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
The Pittsburgh Sleep Quality Index: a new instrument for psychiatric practice and research
Buysse, D. J., Reynolds, C. F., Monk, T. H., Berman, S. R., & Kupfer, D. J. (1989) · Psychiatry Research · doi:10.1016/0165-1781(89)90047-4 · Cited by 35,234
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Rechtschaffen, A. (1968) · Medical Entomology and Zoology · Cited by 12,638
Sheikh (1986) · doi:10.1300/j018v05n01_09 · Cited by 7,236
Statistical methods for assessing agreement between two methods of clinical measurement
Bland, J. M., & Altman, D. G. (2010) · International Journal of Nursing Studies · doi:10.1016/j.ijnurstu.2009.10.001 · Cited by 5,220
Allan Hobson, J. (1969) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(69)90021-2 · Cited by 5,192
The Role of Actigraphy in the Study of Sleep and Circadian Rhythms
Ancoli-Israel, S., Cole, R., Alessi, C., Chambers, M., Moorcroft, W., & Pollak, C. P. (2003) · Sleep · doi:10.1093/sleep/26.3.342 · Cited by 2,751
Self-citationAutomatic Sleep/Wake Identification From Wrist Activity
Cole, R. J., Kripke, D. F., Gruen, W., Mullaney, D. J., & Gillin, J. C. (1992) · Sleep · doi:10.1093/sleep/15.5.461 · Cited by 1,941
The Mini-Mental State Examination
Folstein, M. F. (1983) · Archives of General Psychiatry · doi:10.1001/archpsyc.1983.01790060110016 · Cited by 1,936
Cited by
Mollayeva, T., Thurairajah, P., Burton, K., Mollayeva, S., Shapiro, C. M., & Colantonio, A. (2016) · Sleep Medicine Reviews · doi:10.1016/j.smrv.2015.01.009 · Cited by 1,847
Martin, J. L., & Hakim, A. D. (2011) · Chest · doi:10.1378/chest.10-1872 · Cited by 603
Estimating sleep parameters using an accelerometer without sleep diary
van Hees, V. T., Sabia, S., Jones, S. E., Wood, A. R., Anderson, K. N., Kivimäki, M., Frayling, T. M., Pack, A. I., Bucan, M., Trenell, M. I., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-31266-z · Cited by 554
A survey on sleep assessment methods
Ibáñez, V., Silva, J., & Cauli, O. (2018) · PeerJ · doi:10.7717/peerj.4849 · Cited by 316
Monitoring of Physical Activity after Stroke: A Systematic Review of Accelerometry-Based Measures
Gebruers, N., Vanroy, C., Truijen, S., Engelborghs, S., & De Deyn, P. P. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2009.10.025 · Cited by 293
The association between sleep duration and obesity in older adults
Groups, F. T. O. F. I. M. A. T. S. O. O. F. R., Patel, S. R., Blackwell, T., Redline, S., Ancoli-Israel, S., Cauley, J. A., Hillier, T. A., Lewis, C. E., Orwoll, E. S., Stefanick, M. L., et al. (2008) · International Journal of Obesity · doi:10.1038/ijo.2008.198 · Cited by 284
Self-citationActigraphy-Based Assessment of Sleep Parameters
Fekedulegn, D., Andrew, M. E., Shi, M., Violanti, J. M., Knox, S., & Innes, K. E. (2020) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxaa007 · Cited by 261
Sleep duration and all-cause mortality: a critical review of measurement and associations
Kurina, L. M., McClintock, M. K., Chen, J.-H., Waite, L. J., Thisted, R. A., & Lauderdale, D. S. (2013) · Annals of Epidemiology · doi:10.1016/j.annepidem.2013.03.015 · Cited by 218
Beattie, Z., Oyang, Y., Statan, A., Ghoreyshi, A., Pantelopoulos, A., Russell, A., & Heneghan, C. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa9047 · Cited by 198
Jackowska, M., Dockray, S., Hendrickx, H., & Steptoe, A. (2011) · Psychosomatic Medicine · doi:10.1097/psy.0b013e3182359e77 · Cited by 188
Disturbances in melatonin secretion and circadian sleep-wake regulation in Parkinson disease
Bolitho, S. J., Naismith, S. L., Rajaratnam, S. M. W., Grunstein, R. R., Hodges, J. R., Terpening, Z., Rogers, N., & Lewis, S. J. G. (2014) · Sleep Medicine · doi:10.1016/j.sleep.2013.10.016 · Cited by 139
Does social support differentially affect sleep in older adults with versus without insomnia?
Troxel, W. M., Buysse, D. J., Monk, T. H., Begley, A., & Hall, M. (2010) · Journal of Psychosomatic Research · doi:10.1016/j.jpsychores.2010.04.003 · Cited by 106
Sleep Tracking, Wearable Technology, and Opportunities for Research and Clinical Care
Shelgikar, A. V., Anderson, P. F., & Stephens, M. R. (2016) · Chest · doi:10.1016/j.chest.2016.04.016 · Cited by 104
Kim, H. J., Kim, J. H., Park, K.-D., Choi, K.-G., & Lee, H. W. (2011) · Sleep Medicine · doi:10.1016/j.sleep.2010.09.010 · Cited by 78
Capturing sleep–wake cycles by using day-to-day smartphone touchscreen interactions
Borger, J. N., Huber, R., & Ghosh, A. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0147-4 · Cited by 64
Depressive Symptoms and Circadian Activity Rhythm Disturbances in Community-Dwelling Older Women
Maglione, J. E., Ancoli-Israel, S., Peters, K. W., Paudel, M. L., Yaffe, K., Ensrud, K. E., Tranah, G. J., & Stone, K. L. (2014) · The American Journal of Geriatric Psychiatry · doi:10.1016/j.jagp.2012.09.003 · Cited by 49
“In the SOF cohort, this mode has been shown to correlate best with polysomnography for the measurement of sleepewake variables such as wake after sleep onset.(41,42) Participant’s data were fitted to a five-parameter extended cosine model from which six outcome variables were computed (Table 1).”
MethodSelf-citationSleep efficiency and nocturnal hemodynamic dipping in young, normotensive adults
Ross, A. J., Yang, H., Larson, R. A., & Carter, J. R. (2014) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.00211.2014 · Cited by 39
A State-of-Art Review of Digital Technologies for the Next Generation of Tinnitus Therapeutics
Searchfield, G. D., Sanders, P. J., Doborjeh, Z., Doborjeh, M., Boldu, R., Sun, K., & Barde, A. (2021) · Frontiers in Digital Health · doi:10.3389/fdgth.2021.724370 · Cited by 33
Sleep and psychomotor vigilance in female shiftworkers
Ruggiero, J. S., Redeker, N. S., Fiedler, N., Avi-Itzhak, T., & Fischetti, N. (2012) · Biological Research For Nursing · doi:10.1177/1099800411408413 · Cited by 26
“Actigraphy is a reliable and valid sleep measure in laboratory and naturalistic settings (Blackwell et al., 2008; Morgenthaler et al., 2007; Tryon, 2004), and previous researchers have successfully used wrist-worn actigraphs to measure sleep in shiftworkers (Gander, Millar, Webster, & Merry, 2008;…”
BackgroundThe psychotomimetic nature of dreams: An experimental study
Mason, O., & Wakerley, D. (2012) · Schizophrenia Research and Treatment · doi:10.1155/2012/872307 · Cited by 10
Metadata
- Authors
- Blackwell, T., Redline, S., Ancoli-Israel, S., Schneider, J. L., Surovec, S., Johnson, N. L., Cauley, J. A., & Stone, K. L.
- Venue
- Sleep
- Publisher
- Oxford University Press (OUP)
- Published
- 2008-02
- Volume
- 31
- Issue
- 2
- Pages
- 283-291
- ISSN
- 0161-8105 (ISSN-L)
- 1550-9109
- OpenAlex
- W33624241
- Cited by
- 292
- References
- 39
- FWCI
- 16.07
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.