Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 170

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Migration of Intradermally Injected Quantum Dots to Sentinel Organs in Mice

Open access
Gopee, N. V., Roberts, D. W., Webb, P., Cozart, C. R., Siitonen, P. H., Warbritton, A. R., Yu, W. W., Colvin, V. L., Walker, N. J., Howard, P. C.·2007·Toxicological Sciences

Abstract

Topical exposure to nanoscale materials is likely from a variety of sources including sunscreens and cosmetics. Because the in vivo disposition of nanoscale materials is not well understood, we have evaluated the distribution of quantum dots (QDs) following intradermal injection into female SKH-1 hairless mice as a model system for determining tissue localization following intradermal infiltration. The QD (CdSe core, CdS capped, poly[ethylene glycol] coated, 37 nm diameter, 621 nm fluorescence emission) were injected intradermally (ID) on the right dorsal flank. Within minutes following intradermal injection, the highly UV fluorescent QD could be observed moving from the injection sites apparently through the lymphatic duct system to regional lymph nodes. Residual fluorescent QD remained at the site of injection until necropsy at 24 h. Quantification of cadmium and selenium levels after 0, 4, 8, 12, or 24 h in multiple tissues, using inductively coupled plasma mass spectrometry (ICP-MS), showed a time-dependent loss of cadmium from the injection site, and accumulation in the liver, regional draining lymph nodes, kidney, spleen, and hepatic lymph node. Fluorescence microscopy corroborated the ICP-MS results regarding the tissue distribution of QD. The results indicated that (1) ID injected nanoscale QD remained as a deposit in skin and penetrated the surrounding viable subcutis, (2) QD were distributed to draining lymph nodes through the sc lymphatics and to the liver and other organs, and (3) sentinel organs are effective locations for monitoring transdermal penetration of nanoscale materials into animals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1093/toxsci/kfm074

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 170

Metadata

Authors
Gopee, N. V., Roberts, D. W., Webb, P., Cozart, C. R., Siitonen, P. H., Warbritton, A. R., Yu, W. W., Colvin, V. L., Walker, N. J., & Howard, P. C.
Venue
Toxicological Sciences
Published
2007-04-10
Volume
98
Issue
1
Pages
249-257
ISSN
  • 1096-0929 (ISSN-L)
  • 1096-6080
OpenAlex
W2156850514
Cited by
170
References
2
FWCI
11.34
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Migration of Intradermally Injected Quantum Dots to Sentinel Organs in Mice. https://app.cochat.ai/papers/10.1093/toxsci/kfm074
The paper
Gopee, N. V., Roberts, D. W., Webb, P., Cozart, C. R., Siitonen, P. H., Warbritton, A. R., Yu, W. W., Colvin, V. L., Walker, N. J., & Howard, P. C. (2007). Migration of Intradermally Injected Quantum Dots to Sentinel Organs in Mice. Toxicological Sciences. https://doi.org/10.1093/toxsci/kfm074

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.