The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
An arteriovenous loop in a protected space generates a permanent, highly vascular, tissue‐engineered construct
Open accessAbstract
A major obstacle to 3‐dimensional tissue engineering is incorporation of a functional vascular supply to support the expanding new tissue. This is overcome in an in vivo intrinsic vascularization model where an arteriovenous loop (AVL) is placed in a noncollapsible space protected by a polycarbonate chamber. Vascular development and hypoxia were examined from 3 days to 112 days by vascular casting, morphometric, and morphological techniques to understand the model's vascular growth and remodeling parameters for tissue engineering purposes. At 3 days a fibrin exudate surrounded the AVL, providing a scaffold to migrating inflammatory, endothelial, and mesenchymal cells. Capillaries formed between 3 and 7 days. Hypoxia and cell proliferation were maximal at 7 days, followed by a peak in percent vascular volume at 10 days (23.2±03.14% compared with 3.5±92.68% at 3 days, P <0.001). Maximal apoptosis was observed at 112 days. The protected space and spontaneous microcirculatory development in this model suggest it would be applicable for in vivo tissue engineering. A temporal window in a period of intense angiogenesis at 7 to 10 days is optimal for exogenous cell seeding and survival in the chamber, potentially enabling specific tissue outcomes to be achieved.—Lokmic, Z., Stillaert, F., Morrison, W. A., Thompson, E. W., Mitchell, G. M. An arteriovenous loop in a protected space generates a permanent, highly vascular, tissue‐engineered construct. FASEB J. 21, 511–522 (2007)
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vascular endothelial growth factor induced by hypoxia may mediate hypoxia-initiated angiogenesis
Shweiki, D., Itin, A., Soffer, D., & Keshet, E. (1992) · Nature · doi:10.1038/359843a0 · Cited by 4,617
Creation of long-lasting blood vessels
Koike, N., Fukumura, D., Gralla, O., Au, P., Schechner, J. S., & Jain, R. K. (2004) · Nature · doi:10.1038/428138a · Cited by 701
Cited by
Prevascularization in tissue engineering: Current concepts and future directions
Laschke, M. W., & Menger, M. D. (2016) · Biotechnology Advances · doi:10.1016/j.biotechadv.2015.12.004 · Cited by 266
Towards organ printing: engineering an intra-organ branched vascular tree
Visconti, R. P., Kasyanov, V., Gentile, C., Zhang, J., Markwald, R. R., & Mironov, V. (2010) · Expert Opinion on Biological Therapy · doi:10.1517/14712590903563352 · Cited by 224
From Grafts to Human Bioengineered Vascularized Skin Substitutes
Oualla-Bachiri, W., Fernández-González, A., Quiñones-Vico, M. I., & Arias-Santiago, S. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21218197 · Cited by 69
Injectable Therapeutic Organoids Using Sacrificial Hydrogels
Rossen, N. S., Anandakumaran, P. N., zur Nieden, R., Lo, K., Luo, W., Park, C., Huyan, C., Fu, Q., Song, Z., Singh-Moon, R. P., et al. (2020) · iScience · doi:10.1016/j.isci.2020.101052 · Cited by 36
Metadata
- Authors
- Lokmic, Z., Stillaert, F., Morrison, W. A., Thompson, E. W., & Mitchell, G. M.
- Venue
- The FASEB Journal
- Publisher
- Wiley
- Published
- 2006-12-16
- Volume
- 21
- Issue
- 2
- Pages
- 511-522
- ISSN
- 0892-6638 (ISSN-L)
- 1530-6860
- OpenAlex
- W2002348069
- Cited by
- 177
- References
- 2
- FWCI
- 10.29
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An arteriovenous loop in a protected space generates a permanent, highly vascular, tissue‐engineered construct. https://app.cochat.ai/papers/10.1096/fj.06-6614com
- The paper
- Lokmic, Z., Stillaert, F., Morrison, W. A., Thompson, E. W., & Mitchell, G. M. (2007). An arteriovenous loop in a protected space generates a permanent, highly vascular, tissue‐engineered construct. The FASEB Journal. https://doi.org/10.1096/fj.06-6614com
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.