The Effects of Prone Positioning on Intraabdominal Pressure and Cardiovascular and Renal Function in Patients with Acute Lung Injury
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
UNLABELLED: To detect any harmful effects of prone positioning on intraabdominal pressure (IAP) and cardiovascular and renal function, we studied 16 mechanically ventilated patients with acute lung injury randomly in prone and supine positions, without minimizing the restriction of the abdomen. Effective renal blood flow index and glomerular filtration rate index were determined by the paraaminohippurate and inulin clearance techniques. Prone positioning resulted in an increase in IAP from 12 +/- 4 to 14 +/- 5 mm Hg (P < 0.05), PaO(2)/fraction of inspired oxygen from 220 +/- 91 to 267 +/- 82 mm Hg (P < 0.05), cardiac index from 4.1 +/- 1.1 to 4.4 +/- 0.7 L/min (P < 0.05), mean arterial pressure from 77 +/- 10 to 82 +/- 11 mm Hg (P < 0.01), and oxygen delivery index from 600 +/- 156 to 648 +/- 95 mL. min(-)(1). m(-)(2) (P < 0.05). Renal fraction of cardiac output decreased from 19.1% +/- 12.5% to 15.5% +/- 8.8% (P < 0.05), and renal vascular resistance index increased from 11762 +/- 6554 dynes. s. cm(-)(5). m(2) to 15078 +/- 10594 dynes. s. cm(-)(5). m(2) (P < 0.05), whereas effective renal blood flow index, glomerular filtration rate index, filtration fraction, urine volume, fractional sodium excretion, and osmolar and free water clearances remained constant during prone positioning. Prone positioning, when used in patients with acute lung injury, although it is associated with a small increase in IAP, contributes to improved arterial oxygenation and systemic blood flow without affecting renal perfusion and function. Apparently, special support to allow free chest and abdominal movement seems unnecessary when mechanically ventilated, hemodynamically stable patients without abdominal hypertension are proned to improve gas exchange. IMPLICATIONS: Prone positioning is increasingly used to improve gas exchange in patients with acute lung injury. However, during prone positioning an increase in intraabdominal pressure in these critically ill patients may promote dysfunction of other organs. Therefore, we performed a randomized study in mechanically ventilated patients with acute lung injury to investigate the cardiovascular and renal effects of prone positioning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bernard, G. R., Artigas, A., Brigham, K. L., Carlet, J., Falke, K., Hudson, L., Lamy, M., Legall, J. R., Morris, A., & Spragg, R. (1994) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.149.3.7509706 · Cited by 6,746
Controlled Sedation with Alphaxalone-Alphadolone
Ramsay, M. A. E., Savege, T. M., Simpson, B. R. J., & Goodwin, R. (1974) · BMJ · doi:10.1136/bmj.2.5920.656 · Cited by 2,861 · cited 1×
“After inclusion in the study, the patients were placed in air-cushioned beds (MQ/VQ-TheraKair; KCI, Höchstadt, Germany) and sedated with infusions of sufentanil and midazolam to achieve a Ramsay Sedation Score of 5 (19).”
MethodMultiple-Organ Failure: Generalized Autodestructive Inflammation?
Goris, R. J. A. (1985) · Archives of Surgery · doi:10.1001/archsurg.1985.01390340007001 · Cited by 1,289
A simplified acute physiology score for ICU patients
GALL, J.-R. L., LOIRAT, P., ALPEROVITCH, A., GLASER, P., GRANTHIL, C., MATHIEU, D., MERCIER, P., THOMAS, R., & VILLERS, D. (1984) · Critical Care Medicine · doi:10.1097/00003246-198411000-00012 · Cited by 1,251 · cited 2×
“MOF 5 Multiple Organ Failure (12); SAPS 5 Simplified Acute Physiology Score (13).”
BackgroundMethodGATTINONI, L., PELOSI, P., SUTER, P. M., PEDOTO, A., VERCESI, P., & LISSONI, A. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.1.9708031 · Cited by 900 · cited 1×
“(21) observed that in the supine position, average IAP ranges from six millimeters of mercury in patients with intrapulmonary acute respiratory distress syndrome (ARDS) to 16 millimeters of mercury in patients with extrapulmonary ARDS.”
BackgroundGattinoni, L., Pelosi, P., Vitale, G., Pesenti, A., D'Andrea, L., & Mascheroni, D. (1991) · Anesthesiology · doi:10.1097/00000542-199101000-00004 · Cited by 615 · cited 1×
“he prone position has been shown in nonrandomized investigations to redistribute gravitydependent consolidations initially localized in dorsal lung regions ( 1 ).”
BackgroundEffects of the Prone Position on Respiratory Mechanics and Gas Exchange during Acute Lung Injury
PELOSI, P., TUBIOLO, D., MASCHERONI, D., VICARDI, P., CROTTI, S., VALENZA, F., & GATTINONI, L. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.2.97-04023 · Cited by 508 · cited 4×
“(4) recently observed that the improvement in Pao2 during prone positioning correlated with the decrease in thoracoabdominal compliance.”
BackgroundInfluentialThurau, K. (1964) · The American Journal of Medicine · doi:10.1016/0002-9343(64)90181-0 · Cited by 418 · cited 2×
“This phenomenon can be explained by renal autoregulation, which maintains renal perfusion constant over a wide arterial pressure range (24).”
BackgroundTHE EFFECT OF INCREASED INTRA-ABDOMINAL PRESSURE ON RENAL FUNCTION IN MAN 1
Bradley, S. E., & Bradley, G. P. (1947) · Journal of Clinical Investigation · doi:10.1172/jci101867 · Cited by 396 · cited 2×
“15 millimeters of mercury may reduce renal perfusion and function (10).”
BackgroundPappert, D., Rossaint, R., Slama, K., Grüning, T., & Falke, K. J. (1994) · Chest · doi:10.1378/chest.106.5.1511 · Cited by 355 · cited 3×
“Prone positioning in nonrandomized trials decreased pulmonary blood flow to shunt units (2) and increased arterial blood oxygenation in patients with ALI or ARDS (3–5).”
BackgroundIberti, T. J., Lieber, C. E., & Benjamin, E. (1989) · Anesthesiology · doi:10.1097/00000542-198901000-00011 · Cited by 215 · cited 1×
“AG, Melsungen, Germany) during transient clamping of the Foley catheter, as described previously ( 18 ).”
MethodBlanch, L., Mancebo, J., Perez, M., Martinez, M., Mas, A., Betbese, A. J., Joseph, D., Ballús, J., Lucangelo, U., & Bak, E. (1997) · Intensive Care Medicine · doi:10.1007/s001340050453 · Cited by 196 · cited 4×
“Similar results have been documented in mechanically ventilated patients with ARDS (5).”
BackgroundResultInfluentialTHE PULMONARY CIRCULATION TIME, THE QUANTITY OF BLOOD IN THE LUNGS AND THE OUTPUT OF THE HEART
Stewart, G. N. (1921) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1921.58.1.20 · Cited by 168
Gödje, O. L., Peyerl, M., Seebauer, T., Dewald, O., & Reichart, B. (1998) · CHEST Journal · doi:10.1378/chest.113.4.1070 · Cited by 154 · cited 2×
“The transpulmonary double-indicator dilution method was used to estimate cardiac output and intrathoracic blood volume, as described previously (14, 15 ).”
MethodHemodynamic evaluation of the prone position by transesophageal echocardiography
Toyota, S., & Amaki, Y. (1998) · Journal of Clinical Anesthesia · doi:10.1016/s0952-8180(97)00216-x · Cited by 111 · cited 1×
“Our results contradict the reported decrease in venous return (7,8) and cardiac output (9) in anesthetized patients during prone positioning presumed to result from increased IAP.”
ResultPulmonary Gas Exchange Improves in the Prone Position with Abdominal Distension
Mure, M., Glenny, R. W., Domino, K. B., & Hlastala, M. P. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.6.9711104 · Cited by 81
Assessment of Renal Function—Glomerular and Tubular
Duarte, C. G., & Preuss, H. G. (1993) · Clinics in Laboratory Medicine · doi:10.1016/s0272-2712(18)30459-1 · Cited by 81 · cited 5×
“Fractional sodium excretion, osmolar clearance, and free water clearance were calculated with standard formulas (17).”
BackgroundMethodInfluentialTranspulmonary Indicator Dilution: An Alternative Approach for Hemodynamic Monitoring
Hoeft, A. (1995) · Yearbook of intensive care and emergency medicine · doi:10.1007/978-3-642-79154-3_48 · Cited by 37 · cited 2×
“Intrathoracic blood volume index (ITBVI) was calculated as cardiac index (CI) 3 mttICG (14,15).”
MethodSelf-citation
Cited by
The Pediatric Guidelines Sub-Committee for the World Society of the Abdominal Compartment Syndrome, Kirkpatrick, A. W., Roberts, D. J., De Waele, J., Jaeschke, R., Malbrain, M. L. N. G., De Keulenaer, B., Duchesne, J., Bjorck, M., Leppaniemi, A., et al. (2013) · Intensive Care Medicine · doi:10.1007/s00134-013-2906-z · Cited by 1,624
Malbrain, M. L. N. G., Cheatham, M. L., Kirkpatrick, A., Sugrue, M., Parr, M., De Waele, J., Balogh, Z., Leppäniemi, A., Olvera, C., Ivatury, R., et al. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0349-5 · Cited by 1,532
Cheatham, M. L., Malbrain, M. L. N. G., Kirkpatrick, A., Sugrue, M., Parr, M., De Waele, J., Balogh, Z., Leppäniemi, A., Olvera, C., Ivatury, R., et al. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0592-4 · Cited by 763
Malbrain, M. L. N. G., Chiumello, D., Pelosi, P., Bihari, D., Innes, R., Ranieri, V. M., Del Turco, M., Wilmer, A., Brienza, N., Malcangi, V., et al. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000153408.09806.1b · Cited by 731
Nadim, M. K., Forni, L. G., Mehta, R. L., Connor, M. J., Liu, K. D., Ostermann, M., Rimmelé, T., Zarbock, A., Bell, S., Bihorac, A., et al. (2020) · Nature Reviews Nephrology · doi:10.1038/s41581-020-00356-5 · Cited by 690
Metadata
- Authors
- Hering, R., Wrigge, H., Vorwerk, R., Brensing, K. A., Schröder, S., Zinserling, J., Hoeft, A., Spiegel, T. V., & Putensen, C.
- Venue
- Anesthesia & Analgesia
- Published
- 2001-05
- Volume
- 92
- Issue
- 5
- Pages
- 1226-1231
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W1999842312
- Cited by
- 173
- References
- 18
- FWCI
- 4.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.