CoChat

How Does the Plethysmogram Derived from the Pulse Oximeter Relate to Arterial Blood Pressure in Coronary Artery Bypass Graft Patients?

Awad, Aymen A., Ghobashy, M. Ashraf M., Stout, Robert G., Silverman, David G., Shelley, Kirk H. · 2001 · Anesthesia & Analgesia
Cited by 50

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

UNLABELLED: Twenty patients scheduled for coronary artery bypass grafting had their ear and finger oximeter and radial artery blood pressure (Bp(meas)) waveforms collected. The ear and finger pulse oximeter waveforms were analyzed to extract beat-to-beat amplitude and area and width measurements. The Bp(meas) waveforms were analyzed to measured systolic blood pressure (BP), mean BP, and pulse pressure. The correlation coefficient was determined between the derived waveforms from the pulse oximeter and Bp(meas) for the first 10 patients. The ear pulse oximeter width (Width(Ear)) had the best correlation (r = 0.8). Linear regression was done between Width(Ear) and Bp(meas) based on slope (b) and intercept (a) values, BP was calculated (Bp(calc)) in the next 10 patients as: [equation: see text] where i = systolic BP, mean BP, and pulse pressure. The initial bias was too large to be clinically useful. To improve clinical applicability a period of calibration was introduced in which the first 50 readings of Width(Ear) and Bp(meas) for each patient were used to calculate the intercept. After calibration the systolic BP, mean BP and pulse pressure bias values were -2.6, -1.88 and -1.28 mm Hg, and the precision values were 15.9 10.09, and 9.94 mm Hg, respectively. The present attempt to develop a clinically useful method of noninvasive BP measuring was partly successful with the requirement of a calibration period. IMPLICATIONS: Statistical comparison was made between measured blood pressure (BP) from arterial line and calculated BP derived from ear pulse oximeter waveform in 10 patients undergoing coronary artery bypass graft surgery. Using 62,077 paired readings, the mean difference for systolic BP, mean BP, and pulse pressure between the 2 methods was -2.6, -1.88, and -1.28 mm Hg, respectively.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000539-200112000-00022

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 50

Metadata

Authors
Awad, A. A., Ghobashy, M. A. M., Stout, R. G., Silverman, D. G., & Shelley, K. H.
Venue
Anesthesia & Analgesia
Published
2001-12
Volume
93
Issue
6
Pages
1466-1471
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2030855852
Cited by
50
References
2
FWCI
0.62
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: How Does the Plethysmogram Derived from the Pulse Oximeter Relate to Arterial Blood Pressure in Coronary Artery Bypass Graft Patients? https://app.cochat.ai/papers/10.1097/00000539-200112000-00022
The paper
Awad, A. A., Ghobashy, M. A. M., Stout, R. G., Silverman, D. G., & Shelley, K. H. (2001). How Does the Plethysmogram Derived from the Pulse Oximeter Relate to Arterial Blood Pressure in Coronary Artery Bypass Graft Patients? Anesthesia & Analgesia. https://doi.org/10.1097/00000539-200112000-00022

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.