The Impact of Morbid Obesity, Pneumoperitoneum, and Posture on Respiratory System Mechanics and Oxygenation During Laparoscopy
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
UNLABELLED: We studied the effect of morbid obesity, 20 mm Hg pneumoperitoneum, and body posture (30 degrees head down and 30 degrees head up) on respiratory system mechanics, oxygenation, and ventilation during laparoscopy. We hypothesized that insufflation of the abdomen with CO(2) during laparoscopy would produce more impairment of respiratory system mechanics and gas exchange in the morbidly obese than in patients of normal weight. The static respiratory system compliance and inspiratory resistance were computed by using a Servo Screen pulmonary monitor. A continuous blood gas monitor was used to monitor real-time PaCO(2) and PaO(2), and the ETCO(2) was recorded by mass spectrometry. Static compliance was 30% lower and inspiratory resistance 68% higher in morbidly obese supine anesthetized patients compared with normal-weight patients. Whereas body posture (head down and head up) did not induce additional large alterations in respiratory mechanics, pneumoperitoneum caused a significant decrease in static respiratory system compliance and an increase in inspiratory resistance. These changes in the mechanics of breathing were not associated with changes in the alveolar-to-arterial oxygen tension difference, which was larger in morbidly obese patients. Before pneumoperitoneum, morbidly obese patients had a larger ventilatory requirement than the normal-weight patients to maintain normocapnia (6.3 +/- 1.4 L/min versus 5.4 +/- 1.9 L/min, respectively; P = 0.02). During pneumoperitoneum, morbidly obese, supine, anesthetized patients had less efficient ventilation: a 100-mL increase of tidal volume reduced PaCO(2) on average by 5.3 mm Hg in normal-weight patients and by 3.6 mm Hg in morbidly obese patients (P = 0.02). In conclusion, respiratory mechanics during laparoscopy are affected by obesity and pneumoperitoneum but vary little with body position. The PaO(2) was adversely affected only by increased body weight. IMPLICATIONS: Morbid obesity significantly decreases respiratory system compliance and increases inspiratory resistance. Increased body weight, and not altered mechanics of breathing, was associated with worse PaO(2) during laparoscopy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pelosi, P., Croci, M., Ravagnan, I., Tredici, S., Pedoto, A., Lissoni, A., & Gattinoni, L. (1998) · Anesthesia & Analgesia · doi:10.1213/00000539-199809000-00031 · Cited by 655 · cited 1×
“(10) demonstrated that respiratory system compliance exponentially decreases as a function of increased body mass index.”
BackgroundEffects of Obesity on Respiratory Function
Ray, C. S., Sue, D. Y., Bray, G., Hansen, J. E., & Wasserman, K. (1983) · American Review of Respiratory Disease · doi:10.1164/arrd.1983.128.3.501 · Cited by 558 · cited 1×
“Morbid obesity itself may cause significant respiratory system alteration (8,9).”
BackgroundRespiratory system mechanics in sedated, paralyzed, morbidly obese patients
Pelosi, P., Croci, M., Ravagnan, I., Cerisara, M., Vicardi, P., Lissoni, A., & Gattinoni, L. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.82.3.811 · Cited by 273 · cited 6×
“In the obese, changes in pulmonary mechanics accompanying the transition from the upright to supine position are exaggerated, and the FRC may decrease within or below closing capacity in the supine position (8,11,12).”
BackgroundInfluentialPERIOPERATIVE MANAGEMENT OF THE OBESE PATIENT
SHENKMAN, Z., SHIR, Y., & BRODSKY, J. B. (1993) · British Journal of Anaesthesia · doi:10.1093/bja/70.3.349 · Cited by 232 · cited 1×
“S urgery and anesthesia on morbidly obese patients carry an appreciable risk (1).”
BackgroundPutensen-Himmer, G., Putensen, C., Lammer, H., Lingnau, W., Aigner, F., & Benzer, H. (1992) · Anesthesiology · doi:10.1097/00000542-199210000-00010 · Cited by 170 · cited 1×
“neum and systemic resorption of CO2 may have detrimental cardiorespiratory effects (2).”
BackgroundPerilli, V., Sollazzi, L., Bozza, P., Modesti, C., Chierichini, A., Tacchino, R. M., & Ranieri, R. (2000) · Anesthesia & Analgesia · doi:10.1097/00000539-200012000-00041 · Cited by 167 · cited 3×
“In the obese, changes in pulmonary mechanics accompanying the transition from the upright to supine position are exaggerated, and the FRC may decrease within or below closing capacity in the supine position (8,11,12).”
BackgroundResultProne Positioning Improves Pulmonary Function in Obese Patients During General Anesthesia
Pelosi, P., Croci, M., Calappi, E., Mulazzi, D., Cerisara, M., Vercesi, P., Vicardi, P., & Gattinoni, L. (1996) · Anesthesia & Analgesia · doi:10.1213/00000539-199609000-00025 · Cited by 159 · cited 1×
“These findings agree with those of Pelosi et al. ( 15 ).”
ResultCarbon dioxide absorption and gas exchange during pelvic laparoscopy
Tan, P. L., Lee, T. L., & Tweed, W. A. (1992) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/bf03008229 · Cited by 151 · cited 1×
“Typically, normal-weight patients require a 20%– 30% increase in minute ventilation to maintain normocarbia during pelvic laparoscopy in the Trendelenburg position (16).”
BackgroundHedenstierna, G., & Santesson, J. (1976) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1976.tb05036.x · Cited by 139 · cited 1×
“In the obese, changes in pulmonary mechanics accompanying the transition from the upright to supine position are exaggerated, and the FRC may decrease within or below closing capacity in the supine position (8,11,12).”
BackgroundFahy, B. G., Barnas, G. M., Flowers, J. L., Nagle, S. E., & Njoku, M. J. (1995) · Anesthesia & Analgesia · doi:10.1097/00000539-199510000-00015 · Cited by 104 · cited 2×
“(3,4) studied the effects of pneumoperito-”
Background
Cited by
Anesthetic Considerations for Bariatric Surgery
Ogunnaike, B. O., Jones, S. B., Jones, D. B., Provost, D., & Whitten, C. W. (2002) · Anesthesia & Analgesia · doi:10.1097/00000539-200212000-00061 · Cited by 293
Whalen, F. X., Gajic, O., Thompson, G. B., Kendrick, M. L., Que, F. L., Williams, B. A., Joyner, M. J., Hubmayr, R. D., Warner, D. O., & Sprung, J. (2006) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000183655.57275.7a · Cited by 221
“This may reflect the fact that morbidly obese patients have lower respiratory system compliance, higher resistance (6,9,12), and, contrary to wide belief, normal chest wall compliance (6,28,30).”
BackgroundSelf-citationLaparoscopic Total Gastric Vertical Plication in Morbid Obesity
Talebpour, M., & Amoli, B. S. (2007) · Journal of Laparoendoscopic & Advanced Surgical Techniques · doi:10.1089/lap.2006.0128 · Cited by 197
“4,12,13 In a gastric bypass, the risk of mortality and morbidity is high because the procedure is done with a resection and anastomosis.”
Cadi, P., Guenoun, T., Journois, D., Chevallier, J.-M., Diehl, J.-L., & Safran, D. (2008) · British Journal of Anaesthesia · doi:10.1093/bja/aen067 · Cited by 184
Metadata
- Authors
- Sprung, J., Whalley, D. G., Falcone, T., Warner, D. O., Hubmayr, R. D., & Hammel, J.
- Venue
- Anesthesia & Analgesia
- Published
- 2002-05
- Volume
- 94
- Issue
- 5
- Pages
- 1345-1350
- ISSN
- 0003-2999 (ISSN-L)
- OpenAlex
- W2001969875
- Cited by
- 197
- References
- 14
- FWCI
- 5.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Impact of Morbid Obesity, Pneumoperitoneum, and Posture on Respiratory System Mechanics and Oxygenation During Laparoscopy. https://app.cochat.ai/papers/10.1097/00000539-200205000-00056
- The paper
- Sprung, J., Whalley, D. G., Falcone, T., Warner, D. O., Hubmayr, R. D., & Hammel, J. (2002). The Impact of Morbid Obesity, Pneumoperitoneum, and Posture on Respiratory System Mechanics and Oxygenation During Laparoscopy. Anesthesia & Analgesia. https://doi.org/10.1097/00000539-200205000-00056
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.