CoChat

The Impact of Morbid Obesity, Pneumoperitoneum, and Posture on Respiratory System Mechanics and Oxygenation During Laparoscopy

Sprung, Juraj, Whalley, David G., Falcone, Tommaso, Warner, David O., Hubmayr, Rolf D., Hammel, Jeffrey · 2002 · Anesthesia & Analgesia
Cited by 197

The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.

Abstract

UNLABELLED: We studied the effect of morbid obesity, 20 mm Hg pneumoperitoneum, and body posture (30 degrees head down and 30 degrees head up) on respiratory system mechanics, oxygenation, and ventilation during laparoscopy. We hypothesized that insufflation of the abdomen with CO(2) during laparoscopy would produce more impairment of respiratory system mechanics and gas exchange in the morbidly obese than in patients of normal weight. The static respiratory system compliance and inspiratory resistance were computed by using a Servo Screen pulmonary monitor. A continuous blood gas monitor was used to monitor real-time PaCO(2) and PaO(2), and the ETCO(2) was recorded by mass spectrometry. Static compliance was 30% lower and inspiratory resistance 68% higher in morbidly obese supine anesthetized patients compared with normal-weight patients. Whereas body posture (head down and head up) did not induce additional large alterations in respiratory mechanics, pneumoperitoneum caused a significant decrease in static respiratory system compliance and an increase in inspiratory resistance. These changes in the mechanics of breathing were not associated with changes in the alveolar-to-arterial oxygen tension difference, which was larger in morbidly obese patients. Before pneumoperitoneum, morbidly obese patients had a larger ventilatory requirement than the normal-weight patients to maintain normocapnia (6.3 +/- 1.4 L/min versus 5.4 +/- 1.9 L/min, respectively; P = 0.02). During pneumoperitoneum, morbidly obese, supine, anesthetized patients had less efficient ventilation: a 100-mL increase of tidal volume reduced PaCO(2) on average by 5.3 mm Hg in normal-weight patients and by 3.6 mm Hg in morbidly obese patients (P = 0.02). In conclusion, respiratory mechanics during laparoscopy are affected by obesity and pneumoperitoneum but vary little with body position. The PaO(2) was adversely affected only by increased body weight. IMPLICATIONS: Morbid obesity significantly decreases respiratory system compliance and increases inspiratory resistance. Increased body weight, and not altered mechanics of breathing, was associated with worse PaO(2) during laparoscopy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000539-200205000-00056

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 14 references

Cited by

See all 197

Metadata

Authors
Sprung, J., Whalley, D. G., Falcone, T., Warner, D. O., Hubmayr, R. D., & Hammel, J.
Venue
Anesthesia & Analgesia
Published
2002-05
Volume
94
Issue
5
Pages
1345-1350
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2001969875
Cited by
197
References
14
FWCI
5.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Impact of Morbid Obesity, Pneumoperitoneum, and Posture on Respiratory System Mechanics and Oxygenation During Laparoscopy. https://app.cochat.ai/papers/10.1097/00000539-200205000-00056
The paper
Sprung, J., Whalley, D. G., Falcone, T., Warner, D. O., Hubmayr, R. D., & Hammel, J. (2002). The Impact of Morbid Obesity, Pneumoperitoneum, and Posture on Respiratory System Mechanics and Oxygenation During Laparoscopy. Anesthesia & Analgesia. https://doi.org/10.1097/00000539-200205000-00056

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.