Central Venous Oxygen Saturation in Shock: A Study in Man
Open accessThe DOI matches its Crossref record.
Abstract
In two groups of patients, oxygen saturation was determined in blood drawn simultaneously from several locations: superior vena cava (SSVCO2) (central venous blood); right atrium (SRAO2); right ventricle (SRVO2); pulmonary artery (SO2) systemic artery (SARTO2) and inferior vena cava (SIVCO2). Values
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Early goal-directed therapy in the treatment of severe sepsis and septic shock
Rivers, E., Nguyen, B., Havstad, S., Ressler, J., Muzzin, A., Knoblich, B., Peterson, E., & Tomlanovich, M. (2001) · New England Journal of Medicine · doi:10.1056/nejmoa010307 · Cited by 10,743
Reinhart, K., Rudolph, T., Bredle, D. L., Hannemann, L., & Cain, S. M. (1989) · Chest · doi:10.1378/chest.95.6.1216 · Cited by 515
Continuous central venous and pulmonary artery oxygen saturation monitoring in the critically ill
Reinhart, K., Kuhn, H.-J., Hartog, C., & Bredle, D. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2337-y · Cited by 437
Nguyen, H. B., Rivers, E. P., Abrahamian, F. M., Moran, G. J., Abraham, E., Trzeciak, S., Huang, D. T., Osborn, T., Stevens, D., & Talan, D. A. (2006) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2006.02.015 · Cited by 356
Perioperative cardiovascular monitoring of high-risk patients: a consensus of 12
Vincent, J.-L., Pelosi, P., Pearse, R., Payen, D., Perel, A., Hoeft, A., Romagnoli, S., Ranieri, V. M., Ichai, C., Forget, P., et al. (2015) · Critical Care · doi:10.1186/s13054-015-0932-7 · Cited by 243
“In healthy individuals, ScvO2 may be slightly less than SvO2 [75] because of the high oxygen content of effluent venous blood from the kidneys [76], but this relationship is reversed during periods of hemodynamic instability as blood is redistributed to the upper body at the expense of the splanchnic and renal circula…”
BackgroundCentral venous oxygen saturation monitoring in the critically ill patient
Rivers, E. P., Ander, D. S., & Powell, D. (2001) · Current Opinion in Critical Care · doi:10.1097/00075198-200106000-00011 · Cited by 242
Dueck, M. H., Klimek, M., Appenrodt, S., Weigand, C., & Boerner, U. (2005) · Anesthesiology · doi:10.1097/00000542-200508000-00007 · Cited by 216
Lack of Equivalence Between Central and Mixed Venous Oxygen Saturation
Chawla, L. S., Zia, H., Gutierrez, G., Katz, N. M., Seneff, M. G., & Shah, M. (2004) · Chest · doi:10.1378/chest.126.6.1891 · Cited by 198
Bloos, F., & Reinhart, K. (2005) · Intensive Care Medicine · doi:10.1007/s00134-005-2670-9 · Cited by 179
“The difference between the absolute value of ScvO2 and SvO2 changes under conditions of shock [6].”
BackgroundVarpula, M., Karlsson, S., Ruokonen, E., & Pettilä, V. (2006) · Intensive Care Medicine · doi:10.1007/s00134-006-0270-y · Cited by 168
“In this study the difference was more pronounced between inferior vena cava and ScvO2 than for SvO2, but the patient population was small [12].”
Background
Metadata
- Authors
- Lee, J., Wright, F., Barber, R., & Stanley, L.
- Venue
- Anesthesiology
- Published
- 1972-05-01
- Volume
- 36
- Issue
- 5
- Pages
- 472-478
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2029878568
- Cited by
- 165
- References
- 0
- FWCI
- 5.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.