The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Perioperative cardiovascular monitoring of high-risk patients: a consensus of 12
Open accessAbstract
A significant number of surgical patients are at risk of intra- or post-operative complications or both, which are associated with increased lengths of stay, costs, and mortality. Reducing these risks is important for the individual patient but also for health-care planners and managers. Insufficient tissue perfusion and cellular oxygenation due to hypovolemia, heart dysfunction or both is one of the leading causes of perioperative complications. Adequate perioperative management guided by effective and timely hemodynamic monitoring can help reduce the risk of complications and thus potentially improve outcomes. In this review, we describe the various available hemodynamic monitoring systems and how they can best be used to guide cardiovascular and fluid management in the perioperative period in high-risk surgical patients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A trial of intraoperative low-tidal-volume ventilation in abdominal surgery
Futier, E., Constantin, J.-M., Paugam-Burtz, C., Pascal, J., Eurin, M., Neuschwander, A., Marret, E., Beaussier, M., Gutton, C., Lefrant, J.-Y., et al. (2013) · New England Journal of Medicine · doi:10.1056/nejmoa1301082 · Cited by 1,434
Serpa Neto, A., Cardoso, S. O., Manetta, J. A., Pereira, V. G. M., Espósito, D. C., Pasqualucci, M. D. O. P., Damasceno, M. C. T., & Schultz, M. J. (2012) · JAMA · doi:10.1001/jama.2012.13730 · Cited by 843
Cecconi, M., Rhodes, A., Poloniecki, J., Della Rocca, G., & Grounds, R. M. (2009) · Critical Care · doi:10.1186/cc7129 · Cited by 351
Self-citationJansen, T. C., van Bommel, J., Woodward, R., Mulder, P. G. H., & Bakker, J. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181a0f919 · Cited by 177
Cited by
Futier, E., Lefrant, J.-Y., Guinot, P.-G., Godet, T., Lorne, E., Cuvillon, P., Bertran, S., Leone, M., Pastene, B., Piriou, V., et al. (2017) · JAMA · doi:10.1001/jama.2017.14172 · Cited by 917
Mechanisms and treatment of organ failure in sepsis
Lelubre, C., & Vincent, J.-L. (2018) · Nature Reviews Nephrology · doi:10.1038/s41581-018-0005-7 · Cited by 852
Self-citationLess invasive hemodynamic monitoring in critically ill patients
Teboul, J.-L., Saugel, B., Cecconi, M., De Backer, D., Hofer, C. K., Monnet, X., Perel, A., Pinsky, M. R., Reuter, D. A., Rhodes, A., et al. (2016) · Intensive Care Medicine · doi:10.1007/s00134-016-4375-7 · Cited by 328
Self-citationA rational approach to fluid therapy in sepsis
Marik, P., & Bellomo, R. (2016) · British Journal of Anaesthesia · doi:10.1093/bja/aev349 · Cited by 261
Menger, J., Edlinger-Stanger, M., Dworschak, M., & Steinlechner, B. (2018) · Wiener klinische Wochenschrift · doi:10.1007/s00508-018-1403-3 · Cited by 11
Metadata
- Authors
- Vincent, J.-L., Pelosi, P., Pearse, R., Payen, D., Perel, A., Hoeft, A., Romagnoli, S., Ranieri, V. M., Ichai, C., Forget, P., Rocca, G. D., & Rhodes, A.
- Venue
- Critical Care
- Published
- 2015-12
- Volume
- 19
- Issue
- 1
- Pages
- 224-224
- ISSN
- 1364-8535 (ISSN-L)
- OpenAlex
- W2135528075
- Cited by
- 243
- References
- 4
- FWCI
- 22.42
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Perioperative cardiovascular monitoring of high-risk patients: a consensus of 12. https://app.cochat.ai/papers/10.1186/s13054-015-0932-7
- The paper
- Vincent, J.-L., Pelosi, P., Pearse, R., Payen, D., Perel, A., Hoeft, A., Romagnoli, S., Ranieri, V. M., Ichai, C., Forget, P., Rocca, G. D., & Rhodes, A. (2015). Perioperative cardiovascular monitoring of high-risk patients: a consensus of 12. Critical Care. https://doi.org/10.1186/s13054-015-0932-7
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.