Photoplethysmographic derivation of respiratory rate: A review of relevant physiology
Open accessAbstract
An abnormal respiratory rate is often the earliest sign of critical illness. A reliable estimate of respiratory rate is vital in the application of remote telemonitoring systems, which may facilitate early supported discharge from hospital or prompt recognition of physiological deterioration in high-risk patient groups. Traditional approaches use analysis of respiratory sinus arrhythmia from the electrocardiogram (ECG), but this phenomenon is predominantly limited to the young and healthy. Analysis of the photoplethysmogram (PPG) waveform offers an alternative means of non-invasive respiratory rate monitoring, but further development is required to enable reliable estimates. This review conceptualizes the challenge by discussing the effect of respiration on the PPG waveform and the key physiological mechanisms that underpin the derivation of respiratory rate from the PPG.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Respiration and cardiac output are inherently linked, as an increase in respiration rate can directly affect the variation of heart rate through the nervous system reduced inhibitory control.
“Physiologically, respiration and cardiac output are inherently linked, as an increase in respiration rate can directly affect the variation of heart rate through the nervous system reduced inhibitory control [118].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [118]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Textbook of Medical Physiology
Guyton, A. C., & Hall, J. E. (1966) · Annals of Internal Medicine · doi:10.7326/0003-4819-64-6-1363_2 · Cited by 9,760 · see citing works
The American Journal of Physiology
(1899) · The American Naturalist · doi:10.1086/277182 · Cited by 5,680 · see citing works
Textbook of Medical Physiology
Andreiss, I. A. P., Banfíƈ, H., Barac-Latas, V., Crljen, V., Čulo, F., Ćuk, M., Dujić, Ž., Đogaš, Z., Grčević, D., Kučić, N., et al. (2006) · Cited by 1,654 · see citing works
Hemodynamic regulation: investigation by spectral analysis
AKSELROD, S., Gordon, D., Madwed, J. B., Snidman, N. C., Shannon, D. C., & Cohen, R. J. (1985) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1985.249.4.h867 · Cited by 1,293 · see citing works
Respiratory physiology: The essentials
(1975) · British Journal of Diseases of the Chest · doi:10.1016/0007-0971(75)90100-x · Cited by 1,120 · see citing works
Respiratory sinus arrhythmia in humans: how breathing pattern modulates heart rate
Hirsch, J. A., & Bishop, B. (1981) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1981.241.4.h620 · Cited by 1,105 · see citing works
Yasuma, F., & Hayano, J.-I. (2004) · Chest · doi:10.1378/chest.125.2.683 · Cited by 907 · see citing works
The enigma of Mayer waves: facts and models.
JULIEN, C. (2006) · Cardiovascular Research · doi:10.1016/j.cardiores.2005.11.008 · Cited by 670 · see citing works
LUNG FUNCTION STUDIES. II. THE RESPIRATORY DEAD SPACE
Fowler, W. S. (1948) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1948.154.3.405 · Cited by 571 · see citing works
Respiratory physiology — The essentials
(1974) · Tubercle · doi:10.1016/0041-3879(74)90042-7 · Cited by 370 · see citing works
Utility of the Photoplethysmogram in Circulatory Monitoring
Reisner, A. T., Shaltis, P., McCombie, D. B., Asada, H. H., Warner, D. S., & Warner, M. A. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31816c89e1 · Cited by 365 · see citing works
Hayano, J., Yasuma, F., Okada, A., Mukai, S., & Fujinami, T. (1996) · Circulation · doi:10.1161/01.cir.94.4.842 · Cited by 332 · cited 1× · see citing works
“In general, an increase in vessel diameter within the monitored region results in a reduction in transmitted light and a corresponding positive deflection of the (inverted) PPG waveform.”
BackgroundPrediction of Critical Illness During Out-of-Hospital Emergency Care
Seymour, C., Kahn, J., Cooke, C., Watkins, T., Heckbert, S., & Rea, T. (2010) · Journal of the American Medical Association (JAMA) · doi:10.1001/jama.2010.1140 · Cited by 156 · see citing works
Autonomic Control of Skin Microvessels: Assessment by Power Spectrum of Photoplethysmographic Waves
Bernardi, L., Radaelli, A., Soldà, P. L., Coats, A. J. S., REEDER, M. K., Calciati, A., Garrard, C. S., & Sleight, P. (1996) · Clinical Science · doi:10.1042/cs0900345 · Cited by 146 · see citing works
Different Responses of Ear and Finger Pulse Oximeter Wave Form to Cold Pressor Test
Awad, A. A., Ghobashy, M. A. M., Ouda, W., Stout, R. G., Silverman, D. G., & Shelley, K. H. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200106000-00026 · Cited by 127 · see citing works
Non invasive physiological measurements
(1985) · General Pharmacology The Vascular System · doi:10.1016/0306-3623(85)90184-3 · Cited by 119 · see citing works
Non-invasive physiological measurements
Escourrou, P. (1988) · Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.1988.95111 · Cited by 102 · see citing works
What Is the Best Site for Measuring the Effect of Ventilation on the Pulse Oximeter Waveform?
Shelley, K. H., Jablonka, D. H., Alian, A. A., Stout, R. G., Rezkanna, H., & Silverman, D. G. (2006) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000222477.67637.17 · Cited by 99 · see citing works
Nilsson, L., Goscinski, T., Kalman, S., Lindberg, L. ‐., & Johansson, A. (2007) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2007.01375.x · Cited by 88 · see citing works
Kim, J. M., Arakawa, K., Benson, K. T., & Fox, D. K. (1986) · Anesthesia & Analgesia · doi:10.1213/00000539-198612000-00015 · Cited by 86 · see citing works
Dorlas, J. C., Nijboer, J. A., Butijn, W. T., van der Hoeven, G. M. A., Settels, J. J., Wesseling, K. H., & Miller, R. D. (1985) · Anesthesiology · doi:10.1097/00000542-198503000-00022 · Cited by 84 · see citing works
Innes, J. A., Cort, S. C. D., Kox, W., & Guz, A. (1993) · The Journal of Physiology · doi:10.1113/jphysiol.1993.sp019483 · Cited by 83 · see citing works
Nilsson, L. M., Johansson, A., & Kálmán, S. (2005) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.2005.00721.x · Cited by 78 · see citing works
Babchenko, A., Davidson, E. M., Ginosar, Y., Kurz, V., Faib, I., Adler, D., & Nitzan, M. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/2/310 · Cited by 67 · see citing works
Nilsson, L. M., Johansson, A., & Kálmán, S. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02348428 · Cited by 56 · see citing works
Hemodynamic Consequences of Heart-Lung Interactions
Steingrub, J. S., Tidswell, M., & Higgins, T. L. (2003) · Journal of Intensive Care Medicine · doi:10.1177/0885066602250369 · Cited by 56 · see citing works
Nitzan, M., Faib, I., & Friedman, H. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2236285 · Cited by 55 · see citing works
Nilsson, L., Johansson, A., & Kalman, S. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/4/009 · Cited by 55 · see citing works
Interactions between heart rate variability and pulmonary gas exchange efficiency in humans
Sin, P. Y. W., Webber, M. R., Galletly, D. C., Ainslie, P. N., Brown, S. J., Willie, C. K., Sasse, A., Larsen, P., & Tzeng, Y. (2010) · Experimental Physiology · doi:10.1113/expphysiol.2010.052910 · Cited by 52 · see citing works
Accuracy of pulse oximetry in patients with low systemic vascular resistance
Secker, C., & Spiers, P. (1997) · Anaesthesia · doi:10.1111/j.1365-2044.1997.32-az0062.x · Cited by 51 · see citing works
Observations on blood flow related electrical impedance changes in rigid tubes
Visser, K. R., Lamberts, R. P., Korsten, H. H. M., et al. (1976) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00585894 · Cited by 47 · see citing works
Sympathetically induced spontaneous fluctuations of the photoplethysmographic signal
Khanoka, B., Slovik, Y., Landau, D., & Nitzan, M. (2004) · Medical & Biological Engineering & Computing · doi:10.1007/bf02351014 · Cited by 44 · see citing works
Larsen, P., Harty, M., Thiruchelvam, M., & Galletly, D. C. (1997) · International journal of clinical monitoring and computing · doi:10.1007/bf03356582 · Cited by 38 · see citing works
Johansson, A. F., & Strömberg, T. (2000) · Journal of Clinical Monitoring and Computing · doi:10.1023/a:1012260415191 · Cited by 11 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379 · see citing works
Self-citationMa, Y., Zheng, Q., Liu, Y., Shi, B., Xue, X., Ji, W., Liu, Z., Jin, Y., Zou, Y., An, Z., et al. (2016) · Nano Letters · doi:10.1021/acs.nanolett.6b01968 · Cited by 367 · see citing works
Charlton, P. H., Bonnici, T., Tarassenko, L., Clifton, D. A., Beale, R., & Watkinson, P. J. (2016) · Physiological Measurement · doi:10.1088/0967-3334/37/4/610 · Cited by 366 · see citing works
Self-citationSources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring
Fine, J., Branan, K. L., Rodriguez, A. J., Boonya-ananta, T., Ajmal, Ramella-Roman, J. C., McShane, M. J., & Coté, G. L. (2021) · Biosensors · doi:10.3390/bios11040126 · Cited by 348 · see citing works
Advances in Photopletysmography Signal Analysis for Biomedical Applications
Moraes, J. L., Rocha, M. X., Vasconcelos, G. G., Vasconcelos Filho, J. E., De Albuquerque, V. H. C., & Alexandria, A. R. (2018) · Sensors · doi:10.3390/s18061894 · Cited by 292 · see citing works
Wearable Devices for Precision Medicine and Health State Monitoring
Jeong, I. C., Bychkov, D., & Searson, P. C. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2871638 · Cited by 155 · see citing works
Breath rate variability: A novel measure to study the meditation effects
Muniyandi, M., & Soni, R. (2019) · International Journal of Yoga · doi:10.4103/ijoy.ijoy_27_17 · Cited by 82 · see citing works
Birrenkott, D. A., Pimentel, M. A. F., Watkinson, P. J., & Clifton, D. A. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2778265 · Cited by 71 · see citing works
Self-citationDehkordi, P., Garde, A., Molavi, B., Ansermino, J. M., & Dumont, G. A. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.00948 · Cited by 66 · see citing works
Hickey, M., Phillips, J. P., & Kyriacou, P. A. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-015-9761-0 · Cited by 49 · see citing works
- Authors
- Meredith, D. J., Clifton, D., Charlton, P., Brooks, J., Pugh, C. W., & Tarassenko, L.
- Affiliations
- University of Oxford (GB)
- St Thomas' Hospital (GB)
- Corresponding author
- Meredith, D. J.
- Venue
- Journal of Medical Engineering & Technology
- Publisher
- Informa UK Limited
- Published
- 2011-12-20
- Volume
- 36
- Issue
- 1
- Pages
- 1-7
- ISSN
- 0309-1902 (ISSN-L)
- 1464-522X
- OpenAlex
- W2075109859
- Cited by
- 226
- References
- 34
- Citations by year
- 2026: 12 · 2025: 17 · 2024: 17 · 2023: 17 · 2022: 20 · 2021: 19 · 2020: 22 · 2019: 14 · 2018: 16 · 2017: 23 · 2016: 17 · 2015: 13 · 2014: 10 · 2013: 8 · 2012: 1
- FWCI
- 0.49
- Type
- journal article
- Language
- en
- Open access
- green
- kclpure.kcl.ac.uk
- Locations
- Journal of Medical Engineering & Technology (publishedVersion)
- PubMed (publishedVersion)
- Research Portal (King's College London) (submittedVersion)
- Funders
- Wellcome Trust (088877/Z/09/Z)
- Engineering and Physical Sciences Research Council (EP/F058845/1, EP/H019944/1)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Rate Variability and Autonomic Control
- Health Sciences › Medicine › Surgery › Hemodynamic Monitoring and Therapy
- Keywords
- photoplethysmography, respiratory rate estimation, non-invasive respiratory monitoring, remote patient monitoring, critical illness, physiological deterioration, respiratory sinus arrhythmia
- MeSH terms
- Humans, Monitoring, Physiologic, Respiration, Photoplethysmography, Respiratory Rate
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review