The DOI matches its Crossref record.
Anesthetic Depth Defined Using Multiple Noxious Stimuli during Isoflurane/Oxygen Anesthesia I. Motor Reactions
Open accessAbstract
BACKGROUND: Potency of inhaled anesthetics usually is defined by determining the minimal alveolar concentration (MAC) that prevents movement in 50% of patients in response to skin incision. Skin incision, however, is usually only a single event and, thus, determination of potency cannot be repeated in one patient. Traditional MACskin incision cannot be used to predict response to other noxious stimuli. The aim of this study was to investigate the effects of other noxious stimulation patterns and then compare these to MACskin incision measuring the end-tidal isoflurane concentrations with the corresponding arterial concentrations. METHODS: In 26 patients, the end-tidal and corresponding arterial isoflurane concentrations needed to suppress eye opening to verbal command and motor response after trapezius squeeze, 50 Hz electric tetanic stimulation, laryngoscopy, skin incision, and tracheal intubation in 50% of all patients were determined. RESULTS: The end-tidal (equivalent arterial) isoflurane concentrations (mean +/- SE, adjusted to sea level) expressed in vol% (to allow comparison) increased in the following order (mean +/- SE): vocal command 0.37 +/- 0.09 (0.36 +/- 0.09); trapezius squeeze 0.84 +/- 0.07 (0.65 +/- 0.07); laryngoscopy 1.00 +/- 0.12 (0.78 +/- 0.09); tetanic stimulation 1.03 +/- 0.09 (0.80 +/- 0.06); skin incision 1.16 +/- 0.10 (0.97 +/- 0.17); and intubation 1.76 +/- 0.13 (1.32 +/- 0.11). CONCLUSIONS: Different stimuli require different isoflurane concentrations to suppress motor responses. Tetanic stimulation and, to some extent, trapezius squeeze are reproducible and noninvasive stimulation patterns that can be used as an alternative to skin incision when evaluating potency of an anesthetic agent. In contrast to skin incision, they can be repeated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Temperature Monitoring and Perioperative Thermoregulation
Sessler, D. I., Warner, D. S., & Warner, M. A. (2008) · Anesthesiology · doi:10.1097/aln.0b013e31817f6d76 · Cited by 758
Age, Minimum Alveolar Anesthetic Concentration, and Minimum Alveolar Anesthetic Concentration-Awake
Eger, E. I. (2001) · Anesthesia & Analgesia · doi:10.1097/00000539-200110000-00029 · Cited by 346
Effect of age on MAC in humans: a meta-analysis
Mapleson, W. W. (1996) · British Journal of Anaesthesia · doi:10.1093/bja/76.2.179 · Cited by 344
Metadata
- Authors
- Zbinden, A. M., Maggiorini, M., Petersen-Felix, S., Lauber, R., Thomson, D. A., & Minder, C. E.
- Venue
- Anesthesiology
- Published
- 1994-02-01
- Volume
- 80
- Issue
- 2
- Pages
- 253-260
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W1981651633
- Cited by
- 235
- References
- 0
- FWCI
- 16.49
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Anesthetic Depth Defined Using Multiple Noxious Stimuli during Isoflurane/Oxygen Anesthesia I. Motor Reactions. https://app.cochat.ai/papers/10.1097/00000542-199402000-00004
- The paper
- Zbinden, A. M., Maggiorini, M., Petersen-Felix, S., Lauber, R., Thomson, D. A., & Minder, C. E. (1994). Anesthetic Depth Defined Using Multiple Noxious Stimuli during Isoflurane/Oxygen Anesthesia I. Motor Reactions. Anesthesiology. https://doi.org/10.1097/00000542-199402000-00004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.