CoChat

Anesthetic Depth Defined Using Multiple Noxious Stimuli during Isoflurane/Oxygen Anesthesia I. Motor Reactions

Open access
Zbinden, A. M., Maggiorini, M., Petersen-Felix, S., Lauber, R., Thomson, D. A., Minder, C. E. · 1994 · Anesthesiology
Cited by 235

The DOI matches its Crossref record.

Abstract

BACKGROUND: Potency of inhaled anesthetics usually is defined by determining the minimal alveolar concentration (MAC) that prevents movement in 50% of patients in response to skin incision. Skin incision, however, is usually only a single event and, thus, determination of potency cannot be repeated in one patient. Traditional MACskin incision cannot be used to predict response to other noxious stimuli. The aim of this study was to investigate the effects of other noxious stimulation patterns and then compare these to MACskin incision measuring the end-tidal isoflurane concentrations with the corresponding arterial concentrations. METHODS: In 26 patients, the end-tidal and corresponding arterial isoflurane concentrations needed to suppress eye opening to verbal command and motor response after trapezius squeeze, 50 Hz electric tetanic stimulation, laryngoscopy, skin incision, and tracheal intubation in 50% of all patients were determined. RESULTS: The end-tidal (equivalent arterial) isoflurane concentrations (mean +/- SE, adjusted to sea level) expressed in vol% (to allow comparison) increased in the following order (mean +/- SE): vocal command 0.37 +/- 0.09 (0.36 +/- 0.09); trapezius squeeze 0.84 +/- 0.07 (0.65 +/- 0.07); laryngoscopy 1.00 +/- 0.12 (0.78 +/- 0.09); tetanic stimulation 1.03 +/- 0.09 (0.80 +/- 0.06); skin incision 1.16 +/- 0.10 (0.97 +/- 0.17); and intubation 1.76 +/- 0.13 (1.32 +/- 0.11). CONCLUSIONS: Different stimuli require different isoflurane concentrations to suppress motor responses. Tetanic stimulation and, to some extent, trapezius squeeze are reproducible and noninvasive stimulation patterns that can be used as an alternative to skin incision when evaluating potency of an anesthetic agent. In contrast to skin incision, they can be repeated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00000542-199402000-00004

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Zbinden, A. M., Maggiorini, M., Petersen-Felix, S., Lauber, R., Thomson, D. A., & Minder, C. E.
Venue
Anesthesiology
Published
1994-02-01
Volume
80
Issue
2
Pages
253-260
ISSN
0003-3022 (ISSN-L)
OpenAlex
W1981651633
Cited by
235
References
0
FWCI
16.49
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.