Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 261

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

The Bispectral Index Declines During Neuromuscular Block in Fully Awake Persons

Messner, M., Beese, U., Romstöck, J., Dinkel, M., Tschaikowsky, and K.·2003·Anesthesia & Analgesia

Abstract

UNLABELLED: Bispectral index (BIS) is an electroencephalographic variable promoted for measuring depth of anesthesia. Electromyographic activity influences surface electroencephalography and the calculation of BIS. In this study, we sought to determine the effect of spontaneous electromyographic activity on BIS. BIS was monitored in three volunteers by using an Aspect A-1000 monitor. The experiment was repeated in one volunteer. Electromyographic activity was recorded. Alcuronium and succinylcholine were administered. No other drugs were used. In parallel with spontaneous electromyographic activity of the facial muscles, BIS decreased in response to muscle relaxation to a minimum value of 33 and, in the repeated measurement, to a minimum value of 9 when total neuromuscular block was achieved. In two volunteers, no total block was achieved. BIS decreased to a minimal value of 64 and 57, respectively. In turn, recovery of BIS coincided with the reappearance of spontaneous electromyographic activity. During the entire experiment, the volunteers had full consciousness. BIS, assessed by software Version 3.31, correlates with spontaneous electromyographic activity of the facial muscles. BIS failed to detect awareness in completely paralyzed subjects. Thus, in paralyzed patients, BIS monitoring may not reliably indicate a decline in sedation and imminent awareness. IMPLICATIONS: The bispectral index (BIS) is an electroencephalographic variable intended for measuring depth of anesthesia. Electromyographic activity influences the calculation of BIS. We found that the administration of a muscle relaxant to unanesthetized volunteers decreases the bispectral index value. Thus, awareness in totally paralyzed patients cannot be excluded.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1213/01.ane.0000072741.78244.c0

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 261

Metadata

Authors
Messner, M., Beese, U., Romstöck, J., Dinkel, M., & Tschaikowsky, A. K.
Venue
Anesthesia & Analgesia
Published
2003-08
Volume
97
Issue
2
Pages
488-491
ISSN
0003-2999 (ISSN-L)
OpenAlex
W2043115626
Cited by
261
References
7
FWCI
17.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Bispectral Index Declines During Neuromuscular Block in Fully Awake Persons. https://app.cochat.ai/papers/10.1213/01.ane.0000072741.78244.c0
The paper
Messner, M., Beese, U., Romstöck, J., Dinkel, M., & Tschaikowsky, A. K. (2003). The Bispectral Index Declines During Neuromuscular Block in Fully Awake Persons. Anesthesia & Analgesia. https://doi.org/10.1213/01.ane.0000072741.78244.c0

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.