Effects of Mechanical Ventilation on Release of Cytokines into Systemic Circulation in Patients with Normal Pulmonary Function
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Background: Mechanical ventilation with high tidal volumes (V(T)) in contrast to mechanical ventilation with low V(T) has been shown to increase plasma levels of proinflammatory and antiinflammatory mediators in patients with acute lung injury. The authors hypothesized that, in patients without previous lung injury, a conventional potentially injurious ventilatory strategy with high V(T) and zero end-expiratory pressure (ZEEP) will not cause a cytokine release into systemic circulation. Methods: A total of 39 patients with American Society of Anesthesiologists physical status I-II and without signs of systemic infection scheduled for elective surgery with general anesthesia were randomized to receive mechanical ventilation with either (1) V(T) = 15 ml/kg ideal body weight on ZEEP, (2) V(T) = 6 ml/kg ideal body weight on ZEEP, or (3) V(T) = 6 ml/kg ideal body weight on positive end-expiratory pressure of 10 cm H2O. Plasma levels of proinflammatory and antiinflammatory mediators tumor necrosis factor, interleukin (IL)-6, IL-10, and IL-1 receptor antagonist were determined before and 1 h after the initiation of mechanical ventilation. Results: Plasma levels of all cytokines remained low in all settings. IL-6, tumor necrosis factor, and IL-1 receptor antagonist did not change significantly after 1 h of mechanical ventilation. IL-10 was below the detection limit (10 pg/ml) in 35 of 39 patients. There were no differences between groups. Conclusions: Initiation of mechanical ventilation for 1 h in patients without previous lung injury caused no consistent changes in plasma levels of studied mediators. Mechanical ventilation with high V(T) on ZEEP did not result in higher cytokine levels compared with lung-protective ventilatory strategies. Previous lunge damage seems to be mandatory to cause an increase in plasma cytokines after 1 h of high V(T) mechanical ventilation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2000) · New England Journal of Medicine · doi:10.1056/nejm200005043421801 · Cited by 12,941
Effect of a protective-ventilation strategy on mortality in the acute respiratory distress syndrome.
Amato, M. B. P., Barbas, C. S. V., Medeiros, D. M., Magaldi, R. B., Schettino, G. P., Lorenzi-Filho, G., Kairalla, R. A., Deheinzelin, D., Munoz, C., Oliveira, R., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802053380602 · Cited by 3,654 · cited 4×
“improve gas exchange and outcome in patients with ARDS.(8) Recently, Ranieri et al.”
BackgroundInfluentialVentilator-induced Lung Injury: Lessons from Experimental Studies
DREYFUSS, D., & SAUMON, G. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.157.1.9604014 · Cited by 2,297 · cited 2×
“bination with preexisting lung disease may contribute considerably to lung injury, including pneumothorax, alveolar edema, and alveolar rupture.(5,6)”
BackgroundMethodGRADING OF PATIENTS FOR SURGICAL PROCEDURES
Saklad, M. (1941) · Anesthesiology · doi:10.1097/00000542-194105000-00004 · Cited by 1,956 · cited 1×
“for elective extrathoracic surgery with general anesthesia (table 1) were eligible to participate in the study.(14)”
MethodRanieri, V. M., Suter, P. M., Tortorella, C., De Tullio, R., Dayer, J. M., Brienza, A., Bruno, F., & Slutsky, A. S. (1999) · JAMA · doi:10.1001/jama.282.1.54 · Cited by 1,908
Stress distribution in lungs: a model of pulmonary elasticity.
Mead, J., Takishima, T., & Leith, D. (1970) · Journal of Applied Physiology · doi:10.1152/jappl.1970.28.5.596 · Cited by 1,410
Tremblay, L., Valenza, F., Ribeiro, S. P., Li, J., & Slutsky, A. S. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119259 · Cited by 1,330 · cited 3×
“Tremblay et al.(12) found pronounced production of cytokines induced by injurious mechanical ventilation in animals pretreated with intravenous lipopolysaccharides,(12)”
BackgroundTidal ventilation at low airway pressures can augment lung injury.
Muscedere, J. G., Mullen, J. B., Gan, K., & Slutsky, A. S. (1994) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.149.5.8173774 · Cited by 1,244
Stewart, T. E., Meade, M. O., Cook, D. J., Granton, J. T., Hodder, R. V., Lapinsky, S. E., Mazer, C. D., McLean, R. F., Rogovein, T. S., Schouten, B. D., et al. (1998) · New England Journal of Medicine · doi:10.1056/nejm199802053380603 · Cited by 888
BROCHARD, L., ROUDOT-THORAVAL, F., ROUPIE, E., DELCLAUX, C., CHASTRE, J., FERNANDEZ-MONDÉJAR, E., CLÉMENTI, E., MANCEBO, J., FACTOR, P., MATAMIS, D., et al. (1998) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.158.6.9801044 · Cited by 800
Cited by
Severgnini, P., Selmo, G., Lanza, C., Chiesa, A., Frigerio, A., Bacuzzi, A., Dionigi, G., Novario, R., Gregoretti, C., de Abreu, M. G., et al. (2013) · Anesthesiology · doi:10.1097/aln.0b013e31829102de · Cited by 474
Güldner, A., Kiss, T., Serpa Neto, A., Hemmes, S. N. T., Canet, J., Spieth, P. M., Rocco, P. R. M., Schultz, M. J., Pelosi, P., & Gama de Abreu, M. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000754 · Cited by 432
Michelet, P., D’Journo, X.-B., Roch, A., Doddoli, C., Marin, V., Papazian, L., Decamps, I., Bregeon, F., Thomas, P., & Auffray, J.-P. (2006) · Anesthesiology · doi:10.1097/00000542-200611000-00011 · Cited by 400
What Tidal Volumes Should Be Used in Patients without Acute Lung Injury?
Schultz, M. J., Haitsma, J. J., Slutsky, A. S., Gajic, O., & Warltier, D. C. (2007) · Anesthesiology · doi:10.1097/01.anes.0000267607.25011.e8 · Cited by 296
Lellouche, F., Dionne, S., Simard, S., Bussières, J., & Dagenais, F. (2012) · Anesthesiology · doi:10.1097/aln.0b013e3182522df5 · Cited by 283
Wolthuis, E. K., Choi, G., Dessing, M. C., Bresser, P., Lutter, R., Dzoljic, M., van der Poll, T., Vroom, M. B., Hollmann, M., & Schultz, M. J. (2008) · Anesthesiology · doi:10.1097/01.anes.0000296068.80921.10 · Cited by 272
Wolthuis, E. K., Vlaar, A. P., Choi, G., Roelofs, J. J., Juffermans, N. P., & Schultz, M. J. (2009) · Critical Care · doi:10.1186/cc7688 · Cited by 248
“In disagreement with some reports that did not show any effect of larger VTin patients with non-injured lungs [21,22], several articles did display harmful effects of large VT.”
The Pulmonary Immune Effects of Mechanical Ventilation in Patients Undergoing Thoracic Surgery
Schilling, T., Kozian, A., Huth, C., B??hling, F., Kretzschmar, M., Welte, T., & Hachenberg, T. (2005) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000172112.02902.77 · Cited by 248
“This may explain the unchanged TNF- plasma concentrations that were found during conventional mechanical ventilation in anesthetized patients (19).”
BackgroundMechanical ventilation and acute renal failure*
Kuiper, J. W., Groeneveld, A. B. J., Slutsky, A. S., & Plötz, F. B. (2005) · Critical Care Medicine · doi:10.1097/01.ccm.0000165808.30416.ef · Cited by 247
“If there is any mild inflammatory reaction, it would remain compartmentalized to the lungs (121, 122).”
BackgroundPlötz, F. B., Slutsky, A. S., van Vught, A. J., & Heijnen, C. J. (2004) · Intensive Care Medicine · doi:10.1007/s00134-004-2363-9 · Cited by 247
“Whether injurious ventilation of healthy lungs is also associated with increased serum concentrations of inflammatory mediators is less clear [34, 44].”
BackgroundWrigge, H., Uhlig, U., Zinserling, J., Behrends-Callsen, E., Ottersbach, G., Fischer, M., Uhlig, S., & Putensen, C. (2004) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000100663.11852.bf · Cited by 234
“In patients with normal lungs ventilated without surgical co-stimuli for one hour, we did not observe changes in the plasma levels of inflammatory mediators (13).”
BackgroundSelf-citationInterleukin-6 in Surgery, Trauma, and Critical Care Part II: Clinical Implications
Jawa, R. S., Anillo, S., Huntoon, K., Baumann, H., & Kulaylat, M. (2011) · Journal of Intensive Care Medicine · doi:10.1177/0885066610384188 · Cited by 232
“Research suggests that an increase in alveolar-capillary permeability is required for translocation of cytokines from the lungs to the circulation.(69) Furthermore, some clinical work suggests that previous lung damage is necessary for an elevation of systemic cytokine concentrations (IL-6, TNF-a, IL-1ra), following c…”
BackgroundZupancich, E., Paparella, D., Turani, F., Munch, C., Rossi, A., Massaccesi, S., & Ranieri, V. M. (2005) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2004.11.061 · Cited by 220
Schilling, T., Kozian, A., Senturk, M., Huth, C., Reinhold, A., Hedenstierna, G., & Hachenberg, T. (2011) · Anesthesiology · doi:10.1097/aln.0b013e318214b9de · Cited by 214
“This result confirms previous clinical data that demonstrate that different ventilation modes with low or high tidal volumes did not change the plasma concentrations of TNF- , IL-6, IL-10, and IL-1 receptor antagonist in healthy patients.(28) In addition, a single inflation with an airway pressure of 40 cm H2O for 7–3…”
ResultStüber, F., Wrigge, H., Schroeder, S., Wetegrove, S., Zinserling, J., Hoeft, A., & Putensen, C. (2002) · Intensive Care Medicine · doi:10.1007/s00134-002-1321-7 · Cited by 213
“mans [40] indicate that mechanical ventilation of normal lungs alone is not associated with an inflammatory response.”
BackgroundSelf-citationAtelectasis and perioperative pulmonary complications in high-risk patients
Tusman, G., Böhm, S. H., Warner, D. O., & Sprung, J. (2012) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0b013e32834dd1eb · Cited by 211
Atelectasis Causes Vascular Leak and Lethal Right Ventricular Failure in Uninjured Rat Lungs
Duggan, M., McCaul, C. L., McNamara, P. J., Engelberts, D., Ackerley, C., & Kavanagh, B. P. (2003) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200210-1215oc · Cited by 189
Fernandez-Perez, E. R., Sprung, J., Afessa, B., Warner, D. O., Vachon, C. M., Schroeder, D. R., Brown, D. R., Hubmayr, R. D., & Gajic, O. (2009) · Thorax · doi:10.1136/thx.2008.102228 · Cited by 184
Vascular endothelial growth factor and related molecules in acute lung injury
Mura, M., dos Santos, C. C., Stewart, D., & Liu, M. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00202.2004 · Cited by 180
Delirium: acute cognitive dysfunction in the critically ill
Pandharipande, P., Jackson, J., & Ely, E. W. (2005) · Current Opinion in Internal Medicine · doi:10.1097/01.ccx.0000170503.76528.4b · Cited by 172
Metadata
- Authors
- Wrigge, H., Zinserling, J., Stüber, F., von Spiegel, T., Hering, R., Wetegrove, S., Hoeft, A., & Putensen, C.
- Venue
- Anesthesiology
- Published
- 2000-12-01
- Volume
- 93
- Issue
- 6
- Pages
- 1413-1417
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2062246500
- Cited by
- 240
- References
- 27
- FWCI
- 7.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.