CoChat

Tidal Volume Reduction for Prevention of Ventilator-induced Lung Injury in Acute Respiratory Distress Syndrome

BROCHARD, LAURENT, ROUDOT-THORAVAL, FRANÇOISE, ROUPIE, ERIC, DELCLAUX, CHRISTOPHE, CHASTRE, JEAN, FERNANDEZ-MONDÉJAR, ENRIQUE, CLÉMENTI, EVA, MANCEBO, JORDI, FACTOR, PHILLIP, MATAMIS, DIMITRI, RANIERI, MARCO, BLANCH, LLUIS, RODI, GIUSEPPE, MENTEC, HERVÉ, DREYFUSS, DIDIER, FERRER, MIGUEL, BRUN-BUISSON, CHRISTIAN, TOBIN, MARTIN, LEMAIRE, FRANÇOIS · 1998 · American Journal of Respiratory and Critical Care Medicine

The DOI matches its Crossref record, with a small difference in title or year; 39 of the 39 references it cites were found in a registry or an index.

Abstract

Because animal studies have demonstrated that mechanical ventilation at high volume and pressure can be deleterious to the lungs, limitation of airway pressure, allowing hypercapnia if necessary, is already used for ventilation of acute respiratory distress syndrome (ARDS). Whether a systematic and more drastic reduction is necessary is debatable. A multicenter randomized study was undertaken to compare a strategy aimed at limiting the end-inspiratory plateau pressure to 25 cm H2O, using tidal volume (Vt) below 10 ml/kg of body weight, versus a more conventional ventilatory approach (with regard to current practice) using Vt at 10 ml/kg or above and close to normal PaCO2. Both arms used a similar level of positive end-expiratory pressure. A total of 116 patients with ARDS and no organ failure other than the lung were enrolled over 32 mo in 25 centers. The two groups were similar at inclusion. Patients in the two arms were ventilated with different Vt (7.1 ± 1.3 versus 10.3 ± 1.7 ml/kg at Day 1, p < 0.001) and plateau pressures (25.7 ± 5.0 versus 31.7 ± 6.6 cm H2O at Day 1, p < 0.001), resulting in different PaCO2 (59.5 ± 15.0 versus 41.3 ± 7.6 mm Hg, p < 0.001) and pH (7.28 ± 0.09 versus 7.4 ± 0.09, p < 0.001), but a similar level of oxygenation. The new approach did not reduce mortality at Day 60 (46.6% versus 37.9% in control subjects, p = 0.38), the duration of mechanical ventilation (23.1 ± 20.2 versus 21.4 ± 16.3 d, p = 0.85), the incidence of pneumothorax (14% versus 12%, p = 0.78), or the secondary occurrence of multiple organ failure (41% versus 41%, p = 1). We conclude that no benefit could be observed with reduced Vt titrated to reach plateau pressures around 25 cm H2O compared with a more conventional approach in which normocapnia was achieved with plateau pressures already below 35 cm H2O.

Overview

Integrity signals

Registry

Crossref · 10.1164/ajrccm.158.6.9801044

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 39 references

Research works printed but not linked: 2

  1. Webb, 1974, Experimental pulmonary edema due to intermittent positive end-expiratory pressures., Am. Rev. Respir. Dis., 110, 556
  2. Amato, 1996, Improved survival in ARDS: beneficial effects of a lung protective strategy (abstract)., Am. J. Respir. Crit. Care Med., 153, A531

Cited by

See all 800

Metadata

Authors
BROCHARD, L., ROUDOT-THORAVAL, F., ROUPIE, E., DELCLAUX, C., CHASTRE, J., FERNANDEZ-MONDÉJAR, E., CLÉMENTI, E., MANCEBO, J., FACTOR, P., MATAMIS, D., RANIERI, M., BLANCH, L., RODI, G., MENTEC, H., DREYFUSS, D., FERRER, M., BRUN-BUISSON, C., TOBIN, M., & LEMAIRE, F.
Affiliations
  • Inserm (FR)
  • Medical Intensive Care Unit, Henri Mondor Hospital, Assistance Publique–Hôpitaux de Paris, Université Paris XII and INSERM U 492, Créteil, France
Venue
American Journal of Respiratory and Critical Care Medicine
Published
1998-12-01
Volume
158
Issue
6
Pages
1831-1838
ISSN
  • 1073-449X (ISSN-L)
  • 1535-4970
OpenAlex
W2147279870
Cited by
800
References
39
Citations by year
2026: 7 · 2025: 5 · 2024: 7 · 2023: 8 · 2022: 30 · 2021: 18 · 2020: 14 · 2019: 21 · 2018: 15 · 2017: 24 · 2016: 17 · 2015: 22 · 2014: 27 · 2013: 35 · 2012: 30
FWCI
32.89
Type
journal article
Language
en
Open access
closed
Locations
  • American Journal of Respiratory and Critical Care Medicine (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Neonatal Respiratory Health Research
  • Health Sciences › Medicine › Critical Care and Intensive Care Medicine › Nosocomial Infections in ICU
Keywords
acute respiratory distress syndrome, ventilator-induced lung injury, tidal volume reduction, plateau pressure, mechanical ventilation, hypercapnia, positive end-expiratory pressure, mortality, multiple organ failure, pneumothorax, lung-protective ventilation, normocapnia, oxygenation, acid-base balance, mechanical ventilation duration, randomized controlled trials
MeSH terms
Adolescent, Adult, Aged, Body Weight, Carbon Dioxide, Humans, Hydrogen-Ion Concentration, Hypercapnia, Inspiratory Capacity, Lung Diseases, Middle Aged, Multiple Organ Failure, Oxygen, Oxygen Consumption, Pneumothorax, Positive-Pressure Respiration, Pressure, Respiration, Artificial, Pulmonary Ventilation, Respiratory Distress Syndrome, Tidal Volume, Time Factors, Incidence, Survival Rate

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Tidal Volume Reduction for Prevention of Ventilator-induced Lung Injury in Acute Respiratory Distress Syndrome. https://app.cochat.ai/papers/10.1164/ajrccm.158.6.9801044
The paper
BROCHARD, L., ROUDOT-THORAVAL, F., ROUPIE, E., DELCLAUX, C., CHASTRE, J., FERNANDEZ-MONDÉJAR, E., CLÉMENTI, E., MANCEBO, J., FACTOR, P., MATAMIS, D., RANIERI, M., BLANCH, L., RODI, G., MENTEC, H., DREYFUSS, D., FERRER, M., BRUN-BUISSON, C., TOBIN, M., & LEMAIRE, F. (1998). Tidal Volume Reduction for Prevention of Ventilator-induced Lung Injury in Acute Respiratory Distress Syndrome. American Journal of Respiratory and Critical Care Medicine. https://doi.org/10.1164/ajrccm.158.6.9801044

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.