Performance of the ARX-derived Auditory Evoked Potential Index as an Indicator of Anesthetic Depth: A Comparison with Bispectral Index and Hemodynamic Measures during Propofol Administration
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Background: Autoregressive modeling with exogenous input of middle-latency auditory evoked potential (A-Line autoregressive index [AAI]) has been proposed for monitoring anesthetic depth. The aim of the current study was to compare the accuracy of this new index with the Bispectral Index (BIS), predicted effect-site concentration of propofol, and hemodynamic measures. Methods: Twenty female patients scheduled for ambulatory gynecologic surgery received effect compartment controlled infusion of propofol. Target effect-site concentration was started at 1.5 microg/ml and increased every 4 min by 0.5 microg/ml. At every step, sedation level was compared with monitoring values using different clinical scoring systems and reaction to noxious stimulus. Results: Bispectral Index, AAI, and predicted propofol effect-site concentration were accurate indicators for the level of sedation and loss of consciousness. Hemodynamic variables were poor indicators of the hypnotic-anesthetic status of the patient. BIS correlated best with propofol effect-site concentration, followed by AAI. Hemodynamic measurements did not correlate well. No indicators predicted reaction to noxious stimulus. Poststimulus, BIS and AAI showed an increase as a result of arousal. This reaction occurred more rapidly with the AAI than with BIS. Conclusion: Bispectral Index, AAI, and predicted propofol effect-site concentration revealed information on the level of sedation and loss of consciousness but did not predict response to noxious stimulus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tests for comparing elements of a correlation matrix
Steiger, J. H. (1980) · Psychological Bulletin · doi:10.1037/0033-2909.87.2.245 · Cited by 4,621
Glass, P. S., Bloom, M., Kearse, L., Rosow, C., Sebel, P., & Manberg, P. (1997) · Anesthesiology · doi:10.1097/00000542-199704000-00014 · Cited by 1,274
Validity and Reliability of the Observer??s: Assessment of Alertness/Sedation Scale
CHERNIK, D. A., GILLINGS, D., LAINE, H., HENDLER, J., SILVER, J. M., DAVIDSON, A. B., SCHWAM, E. M., & SIEGEL, J. L. (1990) · Journal of Clinical Psychopharmacology · doi:10.1097/00004714-199008000-00003 · Cited by 1,246
Schnider, T. W., Minto, C. F., Gambus, P. L., Andresen, C., Goodale, D. B., Shafer, S. L., & Youngs, E. J. (1998) · Anesthesiology · doi:10.1097/00000542-199805000-00006 · Cited by 1,162 · cited 3×
“Propofol was administered via a computer-assisted continuous-infusion device to a target effect-site concentration (RUGLOOP‡‡) using a three-compartment model enlarged with an effect-site compartment, previously published by Schnider et al.14,15 The target effect-site concentration of propofol (Ce propofol) was comput…”
MethodInfluentialThe Influence of Age on Propofol Pharmacodynamics
Schnider, T. W., Minto, C. F., Shafer, S. L., Gambus, P. L., Andresen, C., Goodale, D. B., & Youngs, E. J. (1999) · Anesthesiology · doi:10.1097/00000542-199906000-00003 · Cited by 1,064 · cited 3×
“Propofol was administered via a computer-assisted continuous-infusion device to a target effect-site concentration (RUGLOOP‡‡) using a three-compartment model enlarged with an effect-site compartment, previously published by Schnider et al.14,15 The target effect-site concentration of propofol (Ce propofol) was comput…”
MethodInfluentialAnesthetic Potency (MAC) Is Independent of Forebrain Structures in the Rat
Rampil, I. J., Mason, P., & Singh, H. (1993) · Anesthesiology · doi:10.1097/00000542-199304000-00014 · Cited by 521 · cited 1×
“We suggest that the poor performance of the rostral central nervous system indicators tested here might support the hypothesis that movement response to a noxious stimulus occurs as a spinal reflex.(34) Only when the information can reach the cerebral cortex via afferent central nervous system pathways, changes might…”
BackgroundSelf-citationLiu, J., Singh, H., & White, P. F. (1997) · Anesthesia & Analgesia · doi:10.1097/00000539-199701000-00033 · Cited by 432 · cited 1×
“The results for Ce propofol and BIS found in this study agree with those previously found by other investigators who used the same scoring systems.(21,26,28,29) The study was also aimed at observing the sensitivity– specificity characteristics for BIS, AAI, and Ce propofol in more detail.”
ResultMeasuring the Performance of Anesthetic Depth Indicators
Smith, W. D., Dutton, R. C., & Smith, T. N. (1996) · Anesthesiology · doi:10.1097/00000542-199601000-00005 · Cited by 418 · cited 3×
“The ability of the different indicators to describe depth of sedation, loss of consciousness, and response to noxious stimulus was evaluated using prediction probability (PK), which compares the performance of indicators having different units of measurements, as developed by Smith et al.(19,20) Consider a predicting…”
BackgroundMethodSelf-citationBruhn, J., Röpcke, H., & Hoeft, A. (2000) · Anesthesiology · doi:10.1097/00000542-200003000-00016 · Cited by 368 · cited 1×
“have a high sensitivity and specificity compared with other processed electroencephalograpic variables.(2,3) For MLAEP, Mantzaridis and Kenny(4) extracted a single nu-”
ResultDrummond, J. C., & Weiskopf, R. B. (2000) · Anesthesiology · doi:10.1097/00000542-200009000-00039 · Cited by 366
Cited by
Bouillon, T. W., Bruhn, J., Radulescu, L., Andresen, C., Shafer, T. J., Cohane, C., & Shafer, S. L. (2004) · Anesthesiology · doi:10.1097/00000542-200406000-00006 · Cited by 375
Depth of anaesthesia monitoring: what’s available, what’s validated and what’s next?
Bruhn, J., Myles, P. S., Sneyd, R., & Struys, M. M. R. F. (2006) · British Journal of Anaesthesia · doi:10.1093/bja/ael120 · Cited by 341
Self-citationEvaluating and monitoring analgesia and sedation in the intensive care unit
Sessler, C. N., Grap, M. J., & Ramsay, M. A. (2008) · Critical Care · doi:10.1186/cc6148 · Cited by 283
The Anesthetic Cascade: A Theory of How Anesthesia Suppresses Consciousness
John, E. R., & Prichep, L. S. (2005) · Anesthesiology · doi:10.1097/00000542-200502000-00030 · Cited by 250
“compared the ASSR and the BIS, and Struys et al.(77) compared the BIS and MLAER.”
ResultVanluchene, A. L. G., Vereecke, H., Thas, O., Mortier, E. P., Shafer, S. L., & Struys, M. M. R. F. (2004) · Anesthesiology · doi:10.1097/00000542-200407000-00008 · Cited by 178
“average technique together with an ARX model and the calculations of the AAI have been described previously.(16) The BIS (BIS version 4.”
BackgroundMethodSelf-citationThe Entwined Mysteries of Anesthesia and Consciousness: Is There a Common Underlying Mechanism?
Hameroff, S. R. (2006) · Anesthesiology · doi:10.1097/00000542-200608000-00024 · Cited by 129
“Similar devices measure entropy in the electroencephalogram, or auditory-evoked synchrony.(18,19) A comprehensive electroencephalographic analysis of anesthetic-induced loss of consciousness was conducted by John and Prichep.”
MethodCurrent status of EEG-based depth-of-consciousness monitoring during general anesthesia
Musialowicz, T., & Lahtinen, P. (2014) · Current Anesthesiology Reports · doi:10.1007/s40140-014-0061-x · Cited by 33
“An anesthesia depth monitor that uses AEP, the AEP A-line Monitor/2 (Danmeter, Denmark), employs a composite AEP/EEG A-line autoregressive index (AAI) [13–15].”
Method
Metadata
- Authors
- Struys, M. M. R. F., Jensen, E. W., Smith, W., Smith, N. T., Rampil, I., Dumortier, F. J. E., Mestach, C., & Mortier, E. P.
- Venue
- Anesthesiology
- Published
- 2002-04-01
- Volume
- 96
- Issue
- 4
- Pages
- 803-816
- ISSN
- 0003-3022 (ISSN-L)
- OpenAlex
- W2126260437
- Cited by
- 223
- References
- 23
- FWCI
- 30.15
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.