PROPORTIONAL MYOELECTRIC HAND CONTROL: AN EVALUATION
The DOI matches its Crossref record.
Abstract
The authors review the principle of proportional myoelectric control, in which the motor voltage of a prosthetic hand varies in direct proportion to the EMG signal, giving the amputee control over speed and force of grip. This type of myoelectric control is contrasted with digital myoelectric control, in which the system is fully on or off, giving the amputee no control over speed of hand opening and closing, and the grip force is increased only by increasing the time of the sustained EMG signal. A survey was conducted of 33 patients wearing the proportional myoelectric hand. Patients rated quickness of opening and closing; control over speed and force; effort required to open and close; and comfort, convenience, and cosmesis of the hand; as well as giving it an overall rating in comparison with their previous terminal device. The ratings were made on a 5- level scale, so that they could be quantified. Patient responses were grouped according to previous experience with a terminal device type: group A: digital myoelectric hand; group B: body-powered terminal device; group C: no terminal device. Differences in group means were compared using Student's ftest. Previous digital hand wearers gave significantly higher ratings to the proportionally controlled hand overall, especially for its quickness, control of speed and force, and the effort required to open and close the hand. Former body-powered terminal device wearers rated the proportionally controlled hand significantly better on control over speed and force and on cosmesis. Amputees with no previous terminal device had no basis for comparison but gave the proportionally controlled hand high ratings on control over speed and force, effort for opening and closing, and cosmesis. The former digital hand wearers rated the proportionally controlled hand significantly lower on convenience. This reflected early problems with battery life and reliability. Of the three groups of patients, the former digital hand wearers were most impressed with the proportionally controlled hand, and gave it the highest overall ratings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Direct neural sensory feedback and control of a prosthetic arm
Dhillon, G. S., & Horch, K. W. (2005) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2005.856072 · Cited by 573
Control of upper limb prostheses: terminology and proportional myoelectric control-a review
Fougner, A., Stavdahl, Ø., Kyberd, P. J., Losier, Y. G., & Parker, P. A. (2012) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2012.2196711 · Cited by 495
An Ankle-Foot Orthosis Powered by Artificial Pneumatic Muscles
Ferris, D. P., Czerniecki, J. M., & Hannaford, B. (2005) · Journal of Applied Biomechanics · doi:10.1123/jab.21.2.189 · Cited by 376
Current state of digital signal processing in myoelectric interfaces and related applications
Hakonen, M., Piitulainen, H., & Visala, A. (2015) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2015.02.009 · Cited by 305
Ison, M., & Artemiadis, P. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/051001 · Cited by 225
“Other adaptations involve slight modifications to traditional classifiers [188–191], with additional post-processing to minimize classification errors [192] and provide user-friendly proportional controls, in which output magnitudes are directly proportional to myoelectric input signals [55, 193] (see section 4.”
BackgroundYoung, A. J., Kuiken, T. A., & Hargrove, L. J. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/5/056021 · Cited by 200
Huang, H., Zhou, P., Li, G., & Kuiken, T. A. (2008) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.910282 · Cited by 187
Deep learning-based artificial vision for grasp classification in myoelectric hands
Ghazaei, G., Alameer, A., Degenaar, P., Morgan, G., & Nazarpour, K. (2017) · Journal of Neural Engineering · doi:10.1088/1741-2552/aa6802 · Cited by 183
“To become fully integrated into an amputee ’ s sensorimotor repertoire, the performance of hand prostheses must still improve greatly [21 – 24].”
BackgroundMatsubara, T., & Morimoto, J. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2250502 · Cited by 179
“For example, in commercially available prosthetic devices [7], EMG signals have been exploited for a proportional control strategy [1] in which the am-”
BackgroundProportional myoelectric control of a virtual object to investigate human efferent control
Gordon, K. E., & Ferris, D. P. (2004) · Experimental Brain Research · doi:10.1007/s00221-004-1970-6 · Cited by 32
“…have dedicated an enormous amount of effort to designing signal processing algorithms for the myoelectric control of upper limb prostheses (Scott 1966; Hogan 1976; Evans et al. 1984; Scott and Parker 1988; Sears and Shaperman 1991; Hudgins et al. 1993; Gallant et al. 1998; Zecca et al. 2002).”
Metadata
- Authors
- Sears, H. H., & Shaperman, J.
- Venue
- American Journal of Physical Medicine & Rehabilitation
- Published
- 1991-02
- Volume
- 70
- Issue
- 1
- Pages
- 20-28
- ISSN
- 0894-9115 (ISSN-L)
- OpenAlex
- W2078918987
- Cited by
- 95
- References
- 0
- FWCI
- 1.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.